MIQE précis: Practical implementation of minimum standard guidelines for fluorescence-based quantitative real-time PCR experiments.
Bustin SA, Beaulieu JF, Huggett J, Jaggi R, Kibenge FS, Olsvik PA, Penning LC, Toegel S. · 2010
Read MIQE précis: Practical implementation of minimum standard guidelines for fluorescence-based quantitative real-time PCR experiments. by Bustin SA, Beaulieu JF, Huggett J, Jaggi R, Kibenge FS, Olsvik PA, Penning LC, Toegel S. (2010) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2955025.txt.
Introduction
Bustin led a group of specialists in a 2010 editorial setting out minimum reporting rules for a common gene measuring method, quantitative real-time PCR. Thousands of papers rest on this technique, yet many report too little detail to judge or repeat the work.
Methods details increasingly shrink into supplements or vanish, and the little shown often exposes sloppy practice. Their summary, a short form of the MIQE guidelines, lists the assay facts every paper should state. It runs from sample handling to analysis choices. It also advises papers whose whole point is checking reference genes. Journals are urged to enforce the checklist.
Catalog record
| CREATOR | Bustin SA, Beaulieu JF, Huggett J, Jaggi R, Kibenge FS, Olsvik PA, Penning LC, Toegel S. |
|---|---|
| YEAR | 2010 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 13 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
MIQE précis: Practical implementation of minimum standard guidelines for fluorescence-based quantitative real-time PCR experiments By Stephen A Bustin, Jean-François Beaulieu, Jim Huggett, Rolf Jaggi, Frederick SB Kibenge, Pål A Olsvik, Louis C Penning, Stefan Toegel Published in: BMC Molecular Biology DOI: 10.1186/1471-2199-11-74 ABSTRACT Abstract The conclusions of thousands of peer-reviewed publications rely on data obtained using fluorescence-based quantitative real-time PCR technology. However, the inadequate reporting of experimental detail, combined with the frequent use of flawed protocols is leading to the publication of papers that may not be technically appropriate. We take the view that this problem requires the delineation of a more transparent and comprehensive reporting policy from scientific journals. This editorial aims to provide practical guidance for the incorporation of absolute minimum standards encompassing the key assay parameters for accurate design, documentation and reporting of qPCR experiments (MIQE précis) and guidance on the publication of pure 'reference gene' articles. BACKGROUND Fluorescence-based quantitative real-time PCR (qPCR) is commonly regarded as a straightforward, mature technology and has become a ubiquitous mainstay of molecular biology. However, obtaining, analysing and interpreting qPCR data is not a trivial issue. The progressive relegation of qPCR materials and methods to online supplements is resulting in an increasing tendency for scientific publications to contain insufficient technical information for that work to be reproduced; frequently that information is lacking altogether. Equally disconcertingly, the modest details included with publications frequently reveal the use of flawed practices that are likely to result in the publication of erroneous conclusions. This often makes it impossible for reviewers and readers to judge a manuscript's technical adequacy, whilst impeding journal editors' ability to reach publication decisions based on its validity and coherence. A set of "MIQE" guidelines proposes a minimum standard for the provision of information for publications utilising qPCR experiments [1]. These cover every aspect of sample acquisition, assay design and validation and data analysis, to provide an ideal tool for the design of de novo assays and are invaluable for guiding reviewers, as well as assisting decision-making by journal editors. However, their exhaustive incorporation of numerous assay-associated details can appear daunting to non-qPCR experts and may render them too complex for the routine reporting of established assays. Consequently, we would like to propose an abridged set of guidelines for covering key parameters of every qPCR assay (MIQE précis). These cover those steps of a qPCR assay that are essential for allowing reviewers, editors and readers to evaluate the technical merits of scientific publications utilising qPCR technology (Figure 1). [Figure: Key criteria delineating essential technical information required for the assessment of a RT-qPCR experiment .] Sample/template As sample handling affects experimental variability, it is essential to report tissue source and to provide information about conditions of storage, particularly if samples have been obtained during the course of a longitudinal study stretching over several years. Any deviations from manufacturers' protocols must be recorded. For RNA templates, the extent of residual genomic DNA contamination must be reported, ideally for each sample, or if numerous samples are being used, for a representative set of samples, by comparing quantification cycles (Cq) obtained with and without reverse transcription (RT) for each nucleic acid target. Where RNA quantities are ample for accurate RNA measurement, both quantity and quality of extracts should be recorded. Although no perfect quality assessment methods exist, measurements such as those obtained from microfluidics-based systems or 3':5'-type assays can serve as basic indicators of RNA integrity [2]. Authors should not quantitatively compare RNAs of widely dissimilar quality, e.g., RIN/RQI values of 4.5 versus 9.5, and be aware that rRNAs yielding similar RIN/RQI numbers can contain mRNAs that differ significantly in their integrity. Every sample or, in the case of very large numbers, representative samples, should also be tested for the absence of inhibitors using either an "alien" spike or a dilution series of target genes. Assay optimisation/validation Database accession numbers, amplicon size and primer sequences must be reported for each target. We would recommend that probe sequences and the identities, positions, and linkages of any dyes and/or modified bases are also reported. We encourage the use of validated assays, e.g. those available from RTPrimerDB, as this helps with assay standardisation and does not require extensive validation. For newly reported assays, the use of primer design software is encouraged. Primer specificity should be validated in silico (BLAST specificity analysis) and empirically (ideally by DNA sequencing, but certainly using gel electrophoresis or melting profiles). Evidence for the optimisation of primer and MgCl2 concentration, as well as that of the annealing temperature should be provided and the PCR efficiency of each assay should be reported. This is most conveniently performed by means of calibration curves, which must be included for review, although only slopes, y intercepts, linear dynamic range and LOD need be included with the publication. A measure of intra-assay variation (repeatability) and for diagnostic assays inter-assay precision (reproducibility) between sites and different operators should also be reported. For multiplexing it is also essential to demonstrate that accurate quantification of multiple targets in a single tube is not impaired. Reverse transcription qPCR (RT-qPCR) Experimental conditions and reagents must be described in detail, especially what priming method has been used for cDNA synthesis. For RT-qPCR assays total RNA concentration should be similar in every sample and we encourage replicates of the RT step to improve reliability. In addition to the DNA contamination control, which need be run only once for each sample, other important controls include: 1. no template controls (NTC). These are essential for detecting PCR contamination and must be performed with every experiment. They help establish conditions for data rejection from assays utilising SYBR Green chemistry, where primer dimers may result in positive Cqs being recorded in the NTCs. NTCs should be the last samples to be dispensed and loaded. 2. positive controls. These are most conveniently performed as target gene-specific dilution curves and are essential if PCR measurements are of low copy numbers and where it is essential to have confidence in a negative result, for example when detecting pathogens. 3. no amplification controls (NAC). These provide valuable information when using probes, as they help monitor any probe degradation. Data analysis We encourage the use of specialist software for data analysis, confidence estimation and outlier identification. The handling of such data must be specified as well as the statistical methods used to evaluate assay precision. Information relating to experimental lay-out must be supplied: we encourage the use of a sample maximisation strategy, i.e., running as many samples as possible in the same run, as opposed to a gene maximisation strategy that analyses multiple genes in the same run. This is because it minimises any technical, run-to-run variation between different samples for the comparison of gene expression levels. If not all samples can be analysed in the same run, identical samples that are tested in both runs ("inter-run calibrators" or IRCs) must be analysed. Measuring the difference in Cq or the normalised relative quantity between the IRCs in different runs allows the calculation of a correction or calibration factor to remove run-to-run differences [3]. Normalisation with reference genes This is an essential component of a reliable qPCR assay: 1. mRNA data are most commonly normalised using reference