Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study.
Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, Pradl R, Stepan M. · 2010
Read Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. by Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, Pradl R, Stepan M. (2010) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2911766.txt.
Introduction
Benes and colleagues tested in 2010 whether guiding fluids during major abdominal surgery by the heartbeat's own variation improves recovery for high-risk patients. The measure, stroke volume variation, tracks how much each heartbeat's output swings with breathing and predicts who will respond to extra fluid. Sixty patients got variation-guided care with a bedside monitor, and sixty got routine care, assigned by chance.
The guided group received fluid in measured boluses whenever variation crossed the target line, rather than by habit or blood pressure alone. Guided patients developed fewer infectious and organ complications in the month after surgery, and markers of tissue under-perfusion ran lower. Intensive care and hospital stays also trended shorter. The trial supports physiology-guided fluids over fixed recipes for fragile patients facing big operations.
Catalog record
| CREATOR | Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, Pradl R, Stepan M. |
|---|---|
| YEAR | 2010 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 47 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study By Jan Benes, Ivan Chytra, Pavel Altmann, Marek Hluchy, Eduard Kasal, Roman Svitak, Richard Pradl, Martin Stepan Published in: Critical Care DOI: 10.1186/cc9070 ABSTRACT Abstract Introduction Stroke volume variation (SVV) is a good and easily obtainable predictor of fluid responsiveness, which can be used to guide fluid therapy in mechanically ventilated patients. During major abdominal surgery, inappropriate fluid management may result in occult organ hypoperfusion or fluid overload in patients with compromised cardiovascular reserves and thus increase postoperative morbidity. The aim of our study was to evaluate the influence of SVV guided fluid optimization on organ functions and postoperative morbidity in high risk patients undergoing major abdominal surgery. Methods Patients undergoing elective intraabdominal surgery were randomly assigned to a Control group (n = 60) with routine intraoperative care and a Vigileo group (n = 60), where fluid management was guided by SVV (Vigileo/FloTrac system). The aim was to maintain the SVV below 10% using colloid boluses of 3 ml/kg. The laboratory parameters of organ hypoperfusion in perioperative period, the number of infectious and organ complications on day 30 after the operation, and the hospital and ICU length of stay and mortality were evaluated. The local ethics committee approved the study. Results The patients in the Vigileo group received more colloid (1425 ml [1000-1500] vs. 1000 ml [540-1250]; P = 0.0028) intraoperatively and a lower number of hypotensive events were observed (2[1-2] Vigileo vs. 3.5[2-6] in Control; P = 0.0001). Lactate levels at the end of surgery were lower in Vigileo (1.78 ± 0.83 mmol/l vs. 2.25 ± 1.12 mmol/l; P = 0.0252). Fewer Vigileo patients developed complications (18 (30%) vs. 35 (58.3%) patients; P = 0.0033) and the overall number of complications was also reduced (34 vs. 77 complications in Vigileo and Control respectively; P = 0.0066). A difference in hospital length of stay was found only in per protocol analysis of patients receiving optimization (9 [8-12] vs. 10 [8-19] days; P = 0.0421). No difference in mortality (1 (1.7%) vs. 2 (3.3%); P = 1.0) and ICU length of stay (3 [2-5] vs. 3 [0.5-5]; P = 0.789) was found. Conclusions In this study, fluid optimization guided by SVV during major abdominal surgery is associated with better intraoperative hemodynamic stability, decrease in serum lactate at the end of surgery and lower incidence of postoperative organ complications. Trial registration Current Controlled Trials ISRCTN95085011. INTRODUCTION Fluid administration in the intraoperative period is an integral part of everyday anesthesiology practice. Adequate intravascular volume replacement is a crucial issue that can seriously affect postoperative organ function and hence outcome [1-3]. Guiding fluid management using standard physiologic variables (blood pressure, heart rate etc) may be associated with a state of occult hypoperfusion [4]. Goal-directed therapy (GDT) was proposed to overcome this problem by introducing different hemodynamic variables into a dynamic perspective of individualized fluid loading and use vasoactive substances to reach predefined goal of optimal preload and/or oxygen delivery [5,6]. In past years, many trials using different devices and goals have been published in the literature demonstrating better outcomes in organ functions [7,8], morbidity [9-14] or even mortality [15]. Esophageal Doppler was used by many for guiding fluid management with good results but its use is partially limited by the need for deep sedation [16] and experienced staff [17]. Also, the reliability in major vascular procedures requiring cross-clamping of descendent aorta could be questioned. Different algorithms for arterial pressure wave analysis have been introduced lately. As arterial cannulation is routinely used for continuous blood pressure monitoring in high-risk patients, their use is not associated with increased invasivity and risk. These monitors are generally well tolerated by patients and easy to maintain. Some of these devices have already been used in GDT trials [12]. With the introduction of arterial pressure waveform analysis, the well-known interaction between stroke volume variation (SVV) and lung inflation during mechanical ventilation [18] has become available for routine clinical use. Several studies documented the usefulness of blood pressure variations and it surrogates (pulse pressure variation or systolic pressure variation) in predicting position on the Frank-Starling curve and hence fluid responsiveness [19-22]. The reliability of automated assessment [23], the influence of ventilator setting [24,25] and afterload modification [26] were also addressed in the literature. Vigileo/FloTrac is a continuous monitor of patient's hemodynamic status on a beat-to-beat basis using online analysis of arterial pressure waveform. Cardiac performance is calculated assessing the arterial tree impedance (defined as coefficient Khi -χ), so no external calibration is needed and the device is ready to use after obtaining basic demographic parameters [27]. In past years, the arterial impedance calculation was criticized and use in clinical practice was debatable [28-30]. However, with software modifications and more frequent calculation of impedance, the device accuracy improved [31,32,35]. Despite some controversy [36,37] it is used in clinical practice. SVV derived by Vigileo/FloTrac has shown good correlation with results acquired from the PiCCO system and with a cut-off value of 9.6% a good sensitivity and specificity for predicting fluid responsiveness [21]. The aim of our prospective randomized study was to examine the effect of SVV-guided fluid therapy in the perioperative care of high-risk surgical patients and its influence on postoperative morbidity and mortality in comparison with standard treatment. MATERIALS AND METHODS This was a prospective, randomized, partially blinded, single-center study conducted between July 2007 and May 2009 at the Department of Anesthesiology and Intensive Care Medicine, at Charles University Teaching Hospital in Plzeň. The trial was approved by local research ethics committee and all patients gave their informed consent. High-risk patients scheduled for major abdominal surgery with anticipated operation time longer than 120 minutes or presumed blood loss exceeding 1,000 ml (i.e. colorectal or pancreatic resections, intraabdominal vascular surgery) were screened for eligibility. At least one operation-related and one patient-related inclusion criteria had to be fulfilled (Table 1). Patients younger than 18 years, with documented arrhythmias and with a weight below 55 kg or above 140 kg were excluded to ensure accuracy of Vigileo/FloTrac measurement [38]. [Table: Inclusion criteria] Patients randomization and outcome measures Patients meeting inclusion criteria were randomized using opaque sealed envelopes to intervention (Vigileo) or control (Control) group. The anesthetist responsible for intra-operative management was aware of the group assignment, whereas all other members of research team, other health care providers and patients were not. Randomization concealment for researchers was broken only at the end of the study for statistical data analysis. In case of intraoperative change in procedure performed (abandoning planned surgery because of inoperability or performing just a minor procedure), study protocol optimization was not realized, but their postoperative outcome was assessed in the intention-to-treat analysis (Figure 1) [Figure: Flow of participants through the trial.] Primary outcome measures were postoperative morbidity based on number of infectious and other organ complications until day 30 after the operation, consistent with previous studies on peri-operative optimization [11,12,16]. Secondary outcome measures were hospital/ICU length of stay and all-cause mortality. These parameters were assessed both on intention-to-treat and per protocol basis. Biochemical parameters of oxygen debt during operation and in early postoperative period (8 hours), that is serum lactate level, central venous oxygen saturation (ScvO2),