Integration, scaling, space-group assignment and post-refinement.

Kabsch W. · 2010

Read Integration, scaling, space-group assignment and post-refinement. by Kabsch W. (2010) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2815666.txt.

Introduction

Kabsch laid out the working principles in 2010 behind key steps of his XDS program for processing crystal diffraction data. The four steps covered are modeling where spots should fall, adding up spot strengths, correcting and scaling the data, and assigning the crystal's symmetry group, called its space group.

Spot positions depend on a small set of values that the program refines until predicted and seen spots agree. The same principles hold whether each rotation image spans a thin slice or a wide angle. Much of the theory dates back about thirty years to film methods, later extended for fast electronic detectors at synchrotron beamlines, machines that make intense X-ray beams. The article explains the methods as XDS applies them.

Catalog record

CREATORKabsch W.
YEAR2010
COLLECTIONPAPERS
FORMATTXT
FILE SIZE48 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC2815666

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Integration, scaling, space-group assignment and post-refinement By Wolfgang Kabsch Published in: Acta Crystallographica Section D: Biological Crystallography DOI: 10.1107/S0907444909047374 ABSTRACT The working principles of important steps in processing rotation data are described as employed by the program XDS. INTRODUCTION The key steps in the processing of diffraction data from single crystals involve (i) modelling of the observed reflection positions in the detector plane, (ii) integration of diffraction intensities, (iii) data correction, scaling and post-refinement and (iv) space-group assignment. Much of the theory and many of the methods for carrying out these steps were developed about three decades ago for processing rotation data recorded on film and were subsequently extended in order to fully exploit the capabilities of a variety of electronic area detectors; some CCD (charge-coupled device) and multiwire detectors as well as a new pixel detector specially developed for data collection at synchrotron beamlines allow the recording of finely sliced rotation data because of their fast data read-out. In this article, the principles of the methods are described as employed by the program XDS (Kabsch, 2010 ▶). These apply equally well to rotation images covering small or large oscillation ranges. A large number of other data-processing systems have been developed which differ in the details of the implementations. Some of these packages were described in chapter 25.2 of Volume F of International Tables for Crystallography (2001 ▶). The theory and practice of pro­cessing fine-sliced data have been discussed by Pflugrath (1997 ▶). MODELLING ROTATION IMAGES The observed diffraction pattern, i.e. the positions of the reflections recorded on the rotation-data images, is controlled by a small set of parameters which must be accurately determined before integration can start. Approximate values for some of these parameters are given by the experimental setup, whereas others may be completely unknown and must be obtained from the rotation images. This is achieved by the automatic location of strong diffraction spots, the extraction of a primitive lattice basis that yields integer indices for the observed reflections and the subsequent refinement of all parameters to minimize the discrepancies between observed and calculated spot positions in the data images. Coordinate systems and parameters 2.1. In the rotation method, the incident-beam wavevector S 0 of length 1/λ (where λ is the wavelength) is fixed while the crystal is rotated around a fixed axis described by a unit vector m 2. S 0 points from the X-ray source towards the crystal. It is assumed that the incident beam and the rotation axis intersect at one point at which the crystal must be located. This point is defined as the origin of a right-handed orthonormal laboratory co­ordinate system {l 1, l 2, l 3}. This fixed but otherwise arbitrary system is used as a reference frame to specify the setup of the diffraction experiment. Diffraction data are assumed to be recorded on a fixed planar detector. A right-handed orthonormal detector co­ordinate system {d 1, d 2, d 3} is defined such that a point with coordinates X, Y in the detector plane is represented by the vector (X − X 0)d 1 + (Y − Y 0)d 2 + F d 3 with respect to the laboratory coordinate system. The origin X 0, Y 0 of the detector plane is found at a distance |F| from the crystal position. It is assumed that the diffraction data are recorded on adjacent non-overlapping rotation images, each covering a constant oscillation range Δϕ, with image No. 1 starting at spindle angle ϕ0. Diffraction geometry is conveniently expressed with respect to a right-handed orthonormal goniostat system {m 1, m 2, m 3}. It is constructed from the rotation axis and the incident-beam direction such that m 1 = (m 2 × S 0)/|m 2 × S 0| and m 3 = m 1 × m 2. The origin of the goniostat system is defined to coincide with the origin of the laboratory system. Finally, a right-handed crystal coordinate system {b 1, b 2, b 3} and its reciprocal basis {, , } are defined to represent the unrotated crystal, i.e. at rotation angle ϕ = 0°, such that any reciprocal-lattice vector can be expressed as = + + , where h, k, l are integers. As shown in §2.2, the location of all diffraction peaks recorded in the data images can be computed from the parameters S 0, m 2, b 1, b 2, b 3, X 0, Y 0, F, d 1, d 2, d 3, ϕ0 and Δϕ. In addition, knowledge of the shape and extent of the diffraction spots is required for accurate estimations of their intensities. This can be achieved by a Gaussian model involving two parameters: the standard deviations of the reflecting range, σM, and of the beam divergence, σD (see §2.3). This leads to an integration region around the spot defined by the parameters δM and δD, which are typically chosen to be 6–10 times larger than σM and σD, respectively. Spot prediction 2.2. Let denote any arbitrary reciprocal-lattice vector if the crystal has not been rotated, i.e. at rotation angle ϕ = 0°. Depending on the diffraction geometry, may be rotated into a position fulfilling the reflecting condition. The required rotation angle ϕ and the coordinates X, Y of the diffracted beam at its intersection with the detector plane can be found from as follows. can be expressed by its components with respect to the orthonormal goniostat system as Rotation by ϕ around axis m 2 changes into , The incident-beam and diffracted-beam wavevectors, S 0 and S, have their termini on the Ewald sphere and satisfy the Laue equations If ρ = denotes the distance of from the rotation axis, solutions for and ϕ can be obtained in terms of as In general there are two solutions according to the sign of ·m 1. If ρ2 < (·m 3)2 or > the Laue equations have no solution and the reciprocal-lattice point is in the ‘blind’ region. If F S·d 3 > 0 the diffracted beam intersects the detector plane at the point which leads to a diffraction spot recorded at detector co­ordinates Standard spot shape 2.3. A reciprocal-lattice point crosses the Ewald sphere by the shortest route only if the crystal happens to be rotated about an axis perpendicular to both the diffracted-beam and incident-beam wavevectors, the ‘β axis’ e 1 = S × S 0/|S × S 0|, as introduced by Schutt & Winkler (1977 ▶). Rotation around the fixed axis m 2, as enforced by the rotation camera, thus leads to an increase in the length of the shortest path by the factor 1/|e 1·m 2|. This motivated the introduction of a coordinate system {e 1, e 2, e 3}, specific for each reflection, which has its origin on the surface of the Ewald sphere at the terminus of the diffracted beam wavevector S, The unit vectors e 1 and e 2 are tangential to the Ewald sphere, while e 3 is perpendicular to e 1 and = S − S 0. The shape of a reflection, as represented with respect to {e 1, e 2, e 3}, then no longer contains geometrical distortions resulting from the fixed rotation axis of the camera and

Read the complete text