Mass spectrometry-based label-free quantitative proteomics.
Zhu W, Smith JW, Huang CM. · 2010
Read Mass spectrometry-based label-free quantitative proteomics. by Zhu W, Smith JW, Huang CM. (2010) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2775274.txt.
Introduction
Zhu, Smith, and Huang reviewed in 2010 mass spectrometry-based label-free quantitative proteomics, methods that compare protein amounts across samples without chemical tags. Studying how protein levels change in complex mixtures needs fast, reproducible, and accurate measurement. Labeling with isotopes or fluorescent dyes works, but many researchers now prefer label-free shotgun approaches for simpler, cleaner workflows.
The review sorts label-free methods into two families. One measures chromatographic ion intensity, such as peptide peak areas or heights. The other counts spectra matched to each protein, more matches meaning more protein. They discuss the technologies behind both, the statistics used to judge real changes, and the software available. Applications in complex proteomics studies round out the survey. Their aim is a practical map for researchers choosing how to quantify proteins without labels.
Catalog record
| CREATOR | Zhu W, Smith JW, Huang CM. |
|---|---|
| YEAR | 2010 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 30 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Mass Spectrometry-Based Label-Free Quantitative Proteomics By Wenhong Zhu, Jeffrey W Smith, Chun-Ming Huang Published in: Journal of Biomedicine and Biotechnology DOI: 10.1155/2010/840518 ABSTRACT Abstract In order to study the differential protein expression in complex biological samples, strategies for rapid, highly reproducible and accurate quantification are necessary. Isotope labeling and fluorescent labeling techniques have been widely used in quantitative proteomics research. However, researchers are increasingly turning to label-free shotgun proteomics techniques for faster, cleaner, and simpler results. Mass spectrometry-based label-free quantitative proteomics falls into two general categories. In the first are the measurements of changes in chromatographic ion intensity such as peptide peak areas or peak heights. The second is based on the spectral counting of identified proteins. In this paper, we will discuss the technologies of these label-free quantitative methods, statistics, available computational software, and their applications in complex proteomics studies. 1. INTRODUCTION Mass spectrometry plays a central role in proteomics [1]. In addition to global profiling of the proteins present within a system at a given time, information on the level of protein expression is increasingly required in proteomics studies [1, 2]. Protein separation and comparison by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE), followed by mass spectrometry (MS) or tandem mass spectrometry (MS/MS) identification is the classical method for quantitative analysis of protein mixtures [3]. In this method, the intensity of the protein stain is used to make a determination regarding the quantity of a particular protein. The development of 2D Fluorescence Difference Gel Electrophoresis (2D-DIGE) gives more accurate and reliable quantification information of protein abundance because the samples to be compared are run together on the same gel, eliminating potential gel-to-gel variation [4]. However, spots on a given 2D gel often contain more than one protein, making quantification ambiguous since it is not immediately apparent which protein in the spot has changed. In addition, any 2D gel approach is subject to the restrictions imposed by the gel method, which include limited dynamic range, difficulty handling hydrophobic proteins, and difficulty detecting proteins with extreme molecular weights and pI values. The development of non-gel-based, “shotgun” proteomic techniques such as Multidimensional Protein Identification (MudPIT) has provided powerful tools for studying large-scale protein expression and characterization in complex biological systems [5, 6]. Non-gel-based quantitative proteomics methods have, therefore, also been developed significantly in recent years. Because the chemical and physical properties of isotope labeled compounds are identical to properties of their natural counterparts except in mass, isotope labeled molecules were incorporated into mass spectrometry-based proteomics methods as internal standards or relative references. A number of stable isotope labeling approaches have been developed for “shotgun” quantitative proteomic analysis. These include Isotope-Coded Affinity Tag (ICAT), Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC), 15N/14N metabolic labeling, 18O/16O enzymatic labeling, Isotope Coded Protein Labeling (ICPL), Tandem Mass Tags (TMT), Isobaric Tags for Relative and Absolute Quantification (iTRAQ), and other chemical labeling [7, 8]. These stable isotope labeling methods have provided valuable flexibility while using quantitative proteomic techniques to study protein changes in complex samples. However, most labeling-based quantification approaches have potential limitations. These include increased time and complexity of sample preparation, requirement for higher sample concentration, high cost of the reagents, incomplete labeling, and the requirement for specific quantification software. Moreover, so far only TMT and iTRAQ allow the comparison of multiple (up to 8) samples at the same time. The other labeling methods can only compare the relative quantity of a protein between 2 and 3 different samples. There has, therefore, been increased interest in label-free shotgun proteomics techniques in order to address some of the issues of labeling methods and achieve faster, cleaner, and simpler quantification results [7, 9–11]. 2. LABEL-FREE QUANTITATIVE PROTEOMICS Regardless of which label-free quantitative proteomics method is used, they all include the following fundamental steps: (i) sample preparation including protein extraction, reduction, alkylation, and digestion; (ii) sample separation by liquid chromatography (LC or LC/LC) and analysis by MS/MS; (iii) data analysis including peptide/protein identification, quantification, and statistical analysis. In protein-labeling approaches, different protein samples are combined together once labeling is finished and the pooled mixtures are then taken through the sample preparation step before being analyzed by a single LC-MS/MS or LC/LC-MS/MS experiment (Figure 1(a)). In contrast, with label-free quantitative methods, each sample is separately prepared, then subjected to individual LC-MS/MS or LC/LC-MS/MS runs (Figure 1(b)). Protein quantification is generally based on two categories of measurements. In the first are the measurements of ion intensity changes such as peptide peak areas or peak heights in chromatography. The second is based on the spectral counting of identified proteins after MS/MS analysis. Peptide peak intensity or spectral count is measured for individual LC-MS/MS or LC/LC-MS/MS runs and changes in protein abundance are calculated via a direct comparison between different analyses. [Figure: General approaches of quantitative proteomics. (a) Shotgun isotope labeling method. After labeling by light and heavy stable isotope, the control and sample are combined and analyzed by LC-MS/MS. The quantification is calculated based on the intensity ratio of isotope-labeled peptide pairs. (b) Label-free quantitative proteomics. Control and sample are subject to individual LC-MS/MS analysis. Quantification is based on the comparison of peak intensity of the same peptide or the spectral count of the same protein.] 2.1. Relative Quantification by Peak Intensity of LC-MS In LC-MS, an ion with a particular m/z is detected and recorded with a particular intensity, at a particular time. It has been observed that signal intensity from electrospray ionization (ESI) correlates with ion concentration [12]. The label-free quantification of peptide/protein via peak intensity in LC-MS was first studied by loading 10 fmol–100 pmol of myoglobin digests to nano-LC and analyzing by LC/MS/MS [13]. When the chromatographic peak areas of the identified peptides were extracted and calculated, the peak areas were found to increase with increased concentration of injected peptides. After the peak areas of all identified myoglobin peptides were combined and plotted against the protein amount, the peak area was found to correlate linearly to the concentration of protein (r2 = 0.991). The strong correlation between chromatographic peak areas and the peptide/protein concentration remained when myoglobin was spiked into a complex mixture (human serum) and its digests were detected by LC-MS/MS. The results of quantitative profiling were further improved by normalizing the calculated peak areas [13, 14]. Although these early studies showed that the relative quantification of the peptides could be achieved via direct comparison of peak intensity of each peptide ion in multiple LC-MS datasets, applying this method for the analysis of changes in protein abundances in complex biological samples had some practical constraints. First, even the same sample can result in differences in the peak intensities of the peptides from run to run. These differences are caused by experimental variations such as differences in sample preparation and sample injection. Normalization is required to account for this kind of variation. Second, any experimental drifts in retention time and m/z will significantly complicate the direct, accurate comparison of multiple LC-MS datasets. Chromatographic shifts may occur as a result of multiple sample injections onto the same reverse-phase LC column. Unaligned peak comparison will result in large variability and inaccuracy in quantification. Thus, highly reproducible LC-MS and careful chromatographic peak alignment are required and critical in this