Noninvasive detection of lung cancer by analysis of exhaled breath.

Bajtarevic A, Ager C, Pienz M, Klieber M, Schwarz K, Ligor M, Ligor T, Filipiak W, Denz H, Fiegl M, Hilbe W, Weiss W, Lukas P, Jamnig H, Hackl M, Haidenberger A, Buszewski B, Miekisch W, Schubert J, Amann A. · 2009

Read Noninvasive detection of lung cancer by analysis of exhaled breath. by Bajtarevic A, Ager C, Pienz M, Klieber M, Schwarz K, Ligor M, Ligor T, Filipiak W, Denz H, Fiegl M, Hilbe W, Weiss W, Lukas P, Jamnig H, Hackl M, Haidenberger A, Buszewski B, Miekisch W, Schubert J, Amann A. (2009) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2761408.txt.

Introduction

Bajtarevic and co-authors tested in 2009 whether exhaled breath analysis can detect lung cancer noninvasively. Lung cancer is a leading cause of death in Europe, and diagnosis often comes late because cheap, sensitive screening is lacking. Breath is painless to collect, so marker compounds in breath could offer early warning if they reliably separate patients from healthy people.

Using two mass spectrometry methods on breath from hundreds of patients and volunteers, they found the common breath compounds isoprene, acetone, and methanol ran slightly lower in patients. A second method found over fifty compounds differing between groups. Panels of marker compounds detected patients with perfect specificity in their sample, though sensitivity stayed moderate, reaching about eighty percent with the largest panel.

Catalog record

CREATORBajtarevic A, Ager C, Pienz M, Klieber M, Schwarz K, Ligor M, Ligor T, Filipiak W, Denz H, Fiegl M, Hilbe W, Weiss W, Lukas P, Jamnig H, Hackl M, Haidenberger A, Buszewski B, Miekisch W, Schubert J, Amann A.
YEAR2009
COLLECTIONPAPERS
FORMATTXT
FILE SIZE60 KB
LICENSECC BY 4.0
RIGHTSCC BY
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC2761408

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Noninvasive detection of lung cancer by analysis of exhaled breath By Amel Bajtarevic, Clemens Ager, Martin Pienz, Martin Klieber, Konrad Schwarz, Magdalena Ligor, Tomasz Ligor, Wojciech Filipiak, Hubert Denz, Michael Fiegl, Wolfgang Hilbe, Wolfgang Weiss Published in: BMC Cancer DOI: 10.1186/1471-2407-9-348 ABSTRACT Abstract Background Lung cancer is one of the leading causes of death in Europe and the western world. At present, diagnosis of lung cancer very often happens late in the course of the disease since inexpensive, non-invasive and sufficiently sensitive and specific screening methods are not available. Even though the CT diagnostic methods are good, it must be assured that "screening benefit outweighs risk, across all individuals screened, not only those with lung cancer". An early non-invasive diagnosis of lung cancer would improve prognosis and enlarge treatment options. Analysis of exhaled breath would be an ideal diagnostic method, since it is non-invasive and totally painless. Methods Exhaled breath and inhaled room air samples were analyzed using proton transfer reaction mass spectrometry (PTR-MS) and solid phase microextraction with subsequent gas chromatography mass spectrometry (SPME-GCMS). For the PTR-MS measurements, 220 lung cancer patients and 441 healthy volunteers were recruited. For the GCMS measurements, we collected samples from 65 lung cancer patients and 31 healthy volunteers. Lung cancer patients were in different disease stages and under treatment with different regimes. Mixed expiratory and indoor air samples were collected in Tedlar bags, and either analyzed directly by PTR-MS or transferred to glass vials and analyzed by gas chromatography mass spectrometry (GCMS). Only those measurements of compounds were considered, which showed at least a 15% higher concentration in exhaled breath than in indoor air. Compounds related to smoking behavior such as acetonitrile and benzene were not used to differentiate between lung cancer patients and healthy volunteers. Results Isoprene, acetone and methanol are compounds appearing in everybody's exhaled breath. These three main compounds of exhaled breath show slightly lower concentrations in lung cancer patients as compared to healthy volunteers (p < 0.01 for isoprene and acetone, p = 0.011 for methanol; PTR-MS measurements). A comparison of the GCMS-results of 65 lung cancer patients with those of 31 healthy volunteers revealed differences in concentration for more than 50 compounds. Sensitivity for detection of lung cancer patients based on presence of (one of) 4 different compounds not arising in exhaled breath of healthy volunteers was 52% with a specificity of 100%. Using 15 (or 21) different compounds for distinction, sensitivity was 71% (80%) with a specificity of 100%. Potential marker compounds are alcohols, aldehydes, ketones and hydrocarbons. Conclusion GCMS-SPME is a relatively insensitive method. Hence compounds not appearing in exhaled breath of healthy volunteers may be below the limit of detection (LOD). PTR-MS, on the other hand, does not need preconcentration and gives much more reliable quantitative results then GCMS-SPME. The shortcoming of PTR-MS is that it cannot identify compounds with certainty. Hence SPME-GCMS and PTR-MS complement each other, each method having its particular advantages and disadvantages. Exhaled breath analysis is promising to become a future non-invasive lung cancer screening method. In order to proceed towards this goal, precise identification of compounds observed in exhaled breath of lung cancer patients is necessary. Comparison with compounds released from lung cancer cell cultures, and additional information on exhaled breath composition in other cancer forms will be important. BACKGROUND Lung cancer is one of the leading causes of death in Europe and the western world. At present, diagnosis of cancer very often happens late in the course of the disease since available diagnostic methods are not sufficiently sensitive and specific. There is strong evidence to suggest that particulate cancers can be detected by molecular analysis of exhaled air [1-9]. Breath analysis represents a new diagnostic technique that is without risk for the patient even if repeated frequently and can provide information beyond conventional analysis of blood and urine [9-16]. It may even be applied with patients at an intensive care unit [17,18] or during surgery [19]. Also real-time analysis of exhaled breath during an ergometer test or during sleep are possible [15,20-22]. Current interest is not only focused on breath of lung cancer patients but also on emission of volatile organic compounds (VOCs) from lung cancer tissue and lung cancer cell cultures [23-26]. In our own investigations we observed the release (or consumption) of various compounds for the cancer cell lines A549, CALU-1 [25], NCI-H2087 [26] and NCI-H1066 (Sponring A, Filipiak W, Mikoviny T, Ager C, Schubert J, Miekisch W, Amann A, Troppmair J: Release of volatile organic compounds from the lung cancer cell line NCI-H1666 in vitro, submitted). It would be most interesting to investigate jointly the composition of exhaled breath of a particular patient and in vitro release of compounds from cancer cells obtained from the same patient (during a tumor resection). Different analytical techniques have been used for analysis of exhaled breath and headspace of cancer cell cultures. One of the most useful technique is gas chromatography and mass spectrometry (GCMS) [5,7,9,11,18,23,27-35]. This technique gives the most detailed analytical information. Other techniques, such as sensor arrays [36] and proton transfer reaction mass spectrometry (PTR-MS) [8] or selected ion flow tube mass spectrometry (SIFT-MS) [37-39] do not need any preconcentration step and can work in on-line mode, even in breath-to-breath resolution. In the present manuscript we present results obtained with GCMS with preconcentration by solid phase microextraction (SPME), and results obtained with PTR-MS. Both techniques have their advantages and shortcomings. PTR-MS measurements do not provide as much information as GCMS, but the technique is more easy to handle. Therefore the number of patients or volunteers investigated by PTR-MS in our laboratory is much higher than the number of persons investigated by GCMS. It has been stated by Phillips et al., that 3481 different compounds have been observed in exhaled breath. Some of these compounds arise in higher concentrations in inhaled air than in exhaled breath, having thus "negative alveolar gradient" [40]. A total of 1753 different compounds was described as having "positive alveolar gradient", i.e., arising in higher concentration in exhaled breath than in inhaled air. Michael Phillips et al. used adsorption of exhaled breath on adsorbents (solid phase extraction, SPE) with subsequent thermodesorption (TD) and GC-MS-analysis [5,7,27,41,42]. In their work, identification of the peaks has been done by spectral library match only without confirmation of retention time. Among sample preparation methods, solid phase microextraction (SPME) is one of the most frequently used. SPME offers a simple and inexpensive alternative to preconcentration on sorbent tubes followed by thermal desorption (SPE). SPME was developed in the late 1980s by Arthur and Pawliszyn [43,44]. This technique was successfully used in determination of volatile compounds in different matrices in environmental, toxicological, and pharmacological analysis. SPME has been also applied to analysis of VOCs in human breath [45]. For the validated identification of potential marker compounds, we prepared calibration mixtures of the respective pure compounds in order to determine the retention time and mass spectra. A particular focus of the present investigation was the comparison of smokers vs. non-smokers within the group of lung cancer patients, and the exclusion of smoking-related compounds from comparisons between lung cancer patients and healthy controls. We recently performed a PTR-MS investigation comparing healthy smokers with