CNV-seq, a new method to detect copy number variation using high-throughput sequencing.
Xie C, Tammi MT. · 2009
Read CNV-seq, a new method to detect copy number variation using high-throughput sequencing. by Xie C, Tammi MT. (2009) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2667514.txt.
Introduction
Xie and Tammi presented in 2009 a method called CNV-seq for spotting copy number changes in DNA using fast modern sequencing. Such changes, where stretches of DNA are gained or lost, are a major source of human variation. The standard tool, a chip-based comparison method, has built-in limits on sharpness and cost.
Their approach counts how many short reads land in each stretch of the genome. A statistical model then calls gains and losses, with confidence values attached. Tests showed that the sheer number of reads matters, not their length, which suits the new machines that pour out millions of short reads. In simulations the method proved highly accurate across a wide range of coverage, and it worked on real data comparing two people's genomes.
Catalog record
| CREATOR | Xie C, Tammi MT. |
|---|---|
| YEAR | 2009 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 31 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
CNV-seq, a new method to detect copy number variation using high-throughput sequencing By Chao Xie, Martti T Tammi Published in: BMC Bioinformatics DOI: 10.1186/1471-2105-10-80 ABSTRACT Abstract Background DNA copy number variation (CNV) has been recognized as an important source of genetic variation. Array comparative genomic hybridization (aCGH) is commonly used for CNV detection, but the microarray platform has a number of inherent limitations. Results Here, we describe a method to detect copy number variation using shotgun sequencing, CNV-seq. The method is based on a robust statistical model that describes the complete analysis procedure and allows the computation of essential confidence values for detection of CNV. Our results show that the number of reads, not the length of the reads is the key factor determining the resolution of detection. This favors the next-generation sequencing methods that rapidly produce large amount of short reads. Conclusion Simulation of various sequencing methods with coverage between 0.1× to 8× show overall specificity between 91.7 – 99.9%, and sensitivity between 72.2 – 96.5%. We also show the results for assessment of CNV between two individual human genomes. BACKGROUND DNA copy number variation (CNV) has long been known as a source of genetic variation, but its importance has only been recognized recently [1,2]. In a landmark study in 2006, Redon and colleagues found that 1,447 CNV regions cover at least 12% of the human genome, with no large stretches exempt from CNV [3]. The CNV regions cover more nucleotide content per genome than single nucleotide polymorphisms (SNPs), suggesting the importance of CNV in genetic diversity [3]. A common way to detect CNV is to utilize microarray-based methods [4]. The most commonly used method, array comparative genomic hybridization (aCGH) was first used to detect CNV a decade ago [5,6]. Microarray-based methods have revolutionized the way of how large-scale genome studies are carried out. Today, the next-generation sequencing technologies are transforming biology research [7]. The rapid development of new sequencing technologies is continuously increasing the speed of sequencing and decreasing the cost. The next-generation sequencing, such as 454 [8], Solexa [9] and SOLiD [10] have already showed advantages over microarrays in several aspects. Apart from being rapid and cheap, data produced by sequencing can be re-used for varied purposes as opposed to data from microarray-based methods that can usually solely be used by one specific study. In addition, reproducibility has been one of the major challenges for microarray technology [11]. The once revolutionizing microarray-based ChIP-Chip technology is being replaced by ChIP-Seq, in which the DNA fragments are sequenced instead of being hybridized to an array [12]. Sequencing-based methods are also used to produce genome-wide DNA methylation profiles, detect SNP, study chromosome translocations and RNA transcriptome profiling [13-20]. Variation in sequencing coverage in genome assemblies has been used as an indicator for potential CNV between an assembled genome and shotgun data from another genome [21,22]. This is analogous to a comparison of copy number between microarray probes and a single set of DNA fragments. There are two major problems with this kind of approach. Given a certain hybridization condition, hybridization efficiency varies among microarray probes. Likewise, given a certain alignment threshold, sequencing errors in combination with differences between genomes may result in erroneous distribution of the reads. Secondly, the number of probes on a microarray does not represent the real copy number of probe sequences in a genome. Likewise, the copy number of DNA segments in an assembled genome may not represent the true one. Notably, the regions containing multiple copies are the most difficult to assemble correctly and is still the key unsolved problem in shotgun assembly [23]. Assembly errors like these cause false variation in the sequencing coverage and thus yield erroneous indication of CNV. In this paper we describe an efficient solution based on a robust model that combines the advantages of aCGH and high-throughput sequencing. We also assessed CNV between two individuals (Dr. J. Craig Venter [24], Dr. James Watson [21]). An implementation of our method is freely available at http://tiger.dbs.nus.edu.sg/CNV-seq. RESULTS AND DISCUSSION The Model We have developed a method to detect CNV by shotgun sequencing, CNV-seq. The method is based on a robust statistical model that allows confidence assessment of observed copy number ratios and is conceptually derived from aCGH (Figure 1). The microarray-based procedure, aCGH involves a whole genome microarray where two sets of labeled genomic fragments are hybridized. Instead of a microarray, CNV-seq uses a sequence as a template and two sets of shotgun reads, one set from each target individual, X and Y (Figure 1). The two sets of shotgun reads are mapped by sequence alignment on a template genome. We use a sliding window approach to analyze the mapped regions and CNVs are detected by computing the number of reads for each individual in each of the windows, yielding ratios. These observed ratios are assessed by the computation of a probability of a random occurrence, given no copy number variation. [Figure: A comparison of the conceptual steps in aCGH and CNV-seq methods. 1. Starting material in both cases is genomic fragments from two genomes. 2. In CNV-seq the fragments are samples and sequenced. 3. Genomic fragments are directly hybridized on to an array. In CNV-seq the mapping is performed by sequence alignment. 4. In microarray the light intensities reflect the number of hybridized fragments. In CNV-seq the number of mapped reads are counted directly. 5. Data analysis, including estimation of copy number ratios, confidence values, etc. 6. Output of the results.] The random sampling in shotgun sequencing results in uneven coverage that may lead to observed coverage ratios that falsely imply CNV. Therefore, a statistical model is essential for the assessment of the probability of false positive ratios. The average number of reads in a region of a genome is dependent on the total number of reads sampled, the length of the genome and the length of the region. We use this relationship to compute a minimum sliding window size to achieve a desired minimum confidence level of the observations. The mean number of reads for X and Y genomes in a sliding window determines the distribution of the ratios. The number of reads in a window is approximately distributed according to Poisson, Po(λ), where the mean number of reads per window is λ, given by [formula: (1)λ=NWG] where N is the total number of sequenced reads, G is the size of the genome and W is the size of the sliding window, and W < <G. We use the Gaussian distribution to approximate the Poisson distribution with mean and variance λ = μ = σ2. This approximation is good when the mean number of reads per window is greater than 10 with continuity correction. The predicted copy number ratio, r in each sliding window can be computed by [formula: (2)r=z×NYNX] where z is the ratio of read counts in the window and NX and NY are the total number of reads in the genomes X and Y respectively. Assuming an independent distribution of the read counts, we can obtain a probability, p of a copy number ratio being r or divergent from 1:1 ratio by a random chance. For this purpose, we need the distribution of the read count