Read The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population. by Illing RO, Kennedy JE, Wu F, ter Haar GR, Protheroe AS, Friend PJ, Gleeson FV, Cranston DW, Phillips RR, Middleton MR. (2005) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2361666.txt.
Introduction
Illing and colleagues reported early Western trials of focused ultrasound for liver and kidney tumors in 2005. The method, HIFU, beams high-intensity sound from outside the body to cook a small zone of tumor, with no cut at all. The device used was a Chinese system already in use in Asia since 1997.
Thirty patients had one treatment session under general anaesthesia, then scans 12 days later. Among 27 patients who could be assessed, 25 showed a clear killed zone in the tumor. Liver tumors responded every time, while kidney tumors succeeded in 67% of cases, a gap the authors reported plainly. Side effects compared well with more invasive methods. Some patients later had tumors removed, letting doctors confirm the scan findings in real tissue.
Catalog record
| CREATOR | Illing RO, Kennedy JE, Wu F, ter Haar GR, Protheroe AS, Friend PJ, Gleeson FV, Cranston DW, Phillips RR, Middleton MR. |
|---|---|
| YEAR | 2005 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 28 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population By R O Illing, J E Kennedy, F Wu, G R ter Haar, A S Protheroe, P J Friend, F V Gleeson, D W Cranston, R R Phillips, M R Middleton Published in: British Journal of Cancer DOI: 10.1038/sj.bjc.6602803 ABSTRACT Abstract High-intensity focused ultrasound (HIFU) provides a potential noninvasive alternative to conventional therapies. We report our preliminary experience from clinical trials designed to evaluate the safety and feasibility of a novel, extracorporeal HIFU device for the treatment of liver and kidney tumours in a Western population. The extracorporeal, ultrasound-guided Model-JC Tumor Therapy System (HAIFU™ Technology Company, China) has been used to treat 30 patients according to four trial protocols. Patients with hepatic or renal tumours underwent a single therapeutic HIFU session under general anaesthesia. Magnetic resonance imaging 12 days after treatment provided assessment of response. The patients were subdivided into those followed up with further imaging alone or those undergoing surgical resection of their tumours, which enabled both radiological and histological assessment. HIFU exposure resulted in discrete zones of ablation in 25 of 27 evaluable patients (93%). Ablation of liver tumours was achieved more consistently than for kidney tumours (100 vs 67%, assessed radiologically). The adverse event profile was favourable when compared to more invasive techniques. HIFU treatment of liver and kidney tumours in a Western population is both safe and feasible. These findings have significant implications for future noninvasive image-guided tumour ablation. Keywords: ablation, clinical, HIFU, kidney, liver Over the last decade, minimally invasive therapies have developed to provide a role in the ablation of solid tumour deposits in the liver and kidney. Radiofrequency waves (Gervais et al, 2003), cryotherapy (Sotsky and Ravikumar, 2002), lasers (Vogl et al, 2004), microwave energy (Shibata et al, 2002), ethanol injection (Livraghi et al, 1995) and high-intensity focused ultrasound (HIFU) (Kennedy, 2005) have all been used to ablate tumours; however, HIFU remains the only modality to be completely extracorporeal. Ultrasound may pass harmlessly through human tissue, yet when focused at high intensities, sufficient energy may be deposited to produce a well-demarcated volume of coagulation necrosis, independent of soft tissue type (Hill et al, 1994). This has been known since the 1940s (Lynn et al, 1942); however, it is only recently that advances in imaging have allowed accurate placement of the acoustic focus and thus its clinical exploitation (Kennedy et al, 2003). The most widely used clinical extracorporeal device is the Model-JC HIFU System (Chongqing HAIFU™ Company). The device has been used in China and the Far East since 1997 (Wu et al, 2004). Recent data suggest a survival advantage when it is used in combination with trans-arterial chemoembolisation (TACE) in patients with unresectable hepatocellular carcinoma (Wu et al, 2005a). There is also data to show that HIFU has a role to play in the relief of intractable pain relating to pancreatic cancer (Wu et al, 2005b). We report results from early phase II studies investigating the safety and feasibility of extracorporeal HIFU for the treatment of liver and kidney tumours in a Western population using this system. PATIENTS AND METHODS All trials were approved by the Oxfordshire Clinical Research Ethics Committee and conformed to GCP guidelines. Patients included both surgical and nonsurgical candidates and each patient had one or more solid tumour deposits in either the liver or kidney (see Figure 1). All patients were over 18 years old and gave written informed consent to take part in the study. Previous surgery, chemo- and biological therapy were permitted provided that they had recovered from any related side effects. No patients had received radiotherapy to the target region in the preceding 12 months. Patients were required to have normal bone marrow function (haemoglobin ⩾10 g dl−1, absolute neutrophil count ⩾1500 mm−3, platelet count ⩾100 000 mm−3), renal function (urea and creatinine <2.5 times upper limit of laboratory normal (ULN) range) and adequate hepatic reserve (prothrombin time ⩽1.5 times ULN, activated partial thromboplastin time ⩽1.5 times ULN, total bilirubin <1.5 times ULN, AST ⩽3 times ULN, alkaline phosphatase <2 times ULN, unless arising from the bone). All patients required an American Society of Anaesthesiologists grade of ⩽2, and a World Health Organization performance status of ⩽1. [Figure: Patient disposition.] General exclusion criteria for all trials included: women who were pregnant or nursing, clinical evidence of brain metastases, subjects with tumours lying <5 mm from vital structures, concurrent antiarrhythmic, anticoagulant or immunosuppressive medication, permanent implanted pacemakers and those who had previously documented severe intra-abdominal adhesions. The Model-JC HIFU System (Chongqing HAIFU™ Company) was used in all cases and has been described previously (Kennedy et al, 2004). Briefly, the device has a 12 cm diameter, single element, piezo-ceramic transducer fronted by acoustic lenses of varying focal lengths, driven at 0.8 or 1.6 MHz. An AU3 US imaging device (Esaote, Genoa, Italy) is mounted coaxially with the high-energy transducer allowing treatment to be guided in real time. Patients received gadolinium contrast-enhanced (CE) magnetic resonance imaging (MRI), baseline blood tests and symptom review prior to HIFU therapy. Each patient received a single HIFU treatment session under general anaesthesia; a double lumen endotracheal tube allowed single lung ventilation, thus minimising organ movement during respiration. Treatment consisted of a combination of single and multiple overlapping ultrasonic pulses directed to the target tumour. According to the trial protocols, a single tumour, or part of a single tumour, was selected for ablation. Grey scale changes visualised on B-mode diagnostic ultrasound during treatment allowed assessment of tissue response. At the time of HIFU treatment, the estimated dimensions of the ablated region were recorded in the anteroposterior (AP), transverse and cranial–caudal dimensions. This provided the reference value by which both radiological and histological observations were assessed. Radiological follow-up for all patients was at 12 days (or within 3 days of day 12) with a further CE-MRI. The MRI sequences used in the evaluation and quantification of ablation varied according to the target organ. Liver tumours were assessed using the reformatted FAME (Fast Acquisition, Multiple Excitation) sequences 1 min postinjection of intravenous gadolinium contrast agent. Kidney tumours were assessed using subtraction films, where the FAME precontrast series was taken from the 1 min postcontrast series. Repeat blood analyses and symptom reviews took place on days 1, 2 and 12. Surgical resection of the tumours in groups 2 and 4 took place within 14 days of HIFU treatment. Patients in groups 1 and 3 had a symptom review on day 30 after treatment. Primary end points of the study were adverse events and variations in clinical laboratory data during the first 28 days following treatment (or until surgical resection). Device-related adverse events were graded according to the Common Toxicity Criteria (Version 2, Final 1/30/98) where applicable. Secondary end points were radiological and histological assessment of response. Radiological response was evaluated in terms of the presence and accuracy of ablation within the target tumour. ‘Accuracy’ was assessed from the 12-day post-HIFU MRI images. Where ablation was seen, the Radiologist commented on whether the zone fell within the target tumour (‘good’) or outside the target tumour (‘poor’). The size of any zone of coagulation necrosis was measured