THE OXYGEN CONSUMPTION OF LUMINOUS BACTERIA.
Harvey EN. · 1928
Read THE OXYGEN CONSUMPTION OF LUMINOUS BACTERIA. by Harvey EN. (1928) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2141004.txt.
Introduction
Glowing bacteria use oxygen as they shine, and E. Newton Harvey sets out in 1928 to measure exactly how much. He checks two methods against each other: a Thunberg micro respirometer, and the time a bacterial emulsion in sea water takes to dim once nearly all dissolved oxygen is gone.
The two methods agree exactly, which strengthens the numbers that follow. At about 21.5 degrees Celsius the average use is tiny per bacterium, and Harvey also gives rates per weight and per surface area. He argues fair comparisons across organisms need oxygen use per unit weight, with plenty of oxygen present. His diffusion estimates suggest oxygen enters a bacterium far more slowly than it crosses gelatin.
Catalog record
| CREATOR | Harvey EN. |
|---|---|
| YEAR | 1928 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 13 KB |
| LICENSE | Public Domain |
| RIGHTS | PUBLIC DOMAIN |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
THE OXYGEN CONSUMPTION OF LUMINOUS BACTERIA By E. Newton Harvey Published in: The Journal of General Physiology DOI: 10.1085/jgp.11.5.469 ABSTRACT Oxygen consumption of luminous bacteria determined by the Thunberg micro respirometer and by the time which elapses before the luminescence of an emulsion of luminous bacteria in sea water begins to dim, when over 99 per cent of the dissolved oxygen has been consumed, agree exactly. Average values for oxygen consumption at an average temperature of 21.5°C. are 4.26 x 10–11 mg. O2 per bacterium; 2.5 x 104 mg. per kilo and 5.6 mg. O2 per sq. m. of bacterial surface. The only correct comparison of the oxygen consumption of different organisms or tissues is in terms of oxygen used per unit weight with a sufficient oxygen tension so that oxygen consumption is independent of oxygen tension. Measurement of the oxygen concentration which just allows full luminescence, compared with a calculation of the oxygen concentration at the surface of a bacterial cell just necessary to allow the observed respiration throughout all parts of the cell, indicates that oxygen must diffuse into the bacterium much more slowly than through gelatin or connective tissue but not as slowly as through chitin. THE OXYGEN CONSUMPTION OF LUMINOUS BACTERIA. B~ E. NEWTONHARVEY. (From the Marine Biological Laboratory, Woods Hole, and the Physiological Laboratory, Princeton University, Princeton.) (Acceptedfor publication, January 18, 1928.) In a previous paper (1925) I have published some figures on the total efficiencyof luminous bacteria, regarded as machines for light produc- tion, which give the ratio of the light emitted to the total energy input, expressed in the same energy units (calories per second). The energy input was calculated by a method of indirect calorimetry, from the oxygen consumption of the bacteria. The oxygen consumed would liberate a definite amount of heat when used to burn the food of the bacteria, a mixture of 40 per cent peptone and 60 per cent glycerol. Since luminescence of the bacteria is dependent on dissolved oxygen, the oxygen consumption was measured by finding the time necessary for an emulsion of the bacteria in sea water to use up the dissolved oxygen to the point where the luminescence just begins to fade. From the solubility of oxygen in sea water one can then calculate the oxygen consumption, provided the bacteria use equal amounts of oxygen in equal times. Experiment shows that the dimming point represents utilization of at least 99.5 per cent of the dissolved oxygen, a change from the dissolved oxygen in equilibrium with air (21 per cent) to that in equilibrium with < 0.5 per cent oxygen, and that the luminescence intensity of the bacteria is unaffected by different oxygen tensions until the tension falls to < 0.5 per cent oxygen.1 The oxygen con- sumption is probably also independent of the oxygen tension until approximately this same value is reached. The time for dimming for an undisturbed tube of bacterial emulsion is proportional to the num- ber of bacteria present, and also approximately proportional to the oxygen tension with which the bacterial emulsion is brought into equili- ! Unpublishedexperiments. 469 The Journal of General Physiology 470 OXYGEN CONSUMPTION O1~ LUMINOUS BACTERIA brium, provided of course this is above the critical value (0.5 per cent oxygen). The method would therefore appear to be justified, but requires confirmation, which is the subject of this communication. The actual figures obtained (Harvey, 1925) for oxygen consumption of the bacteria in seven experiments at temperatures ranging from 18 to 23C. varied from 6.65 to 17.67 x 10-15 rag. O3 per bacterium per second, with an average of 11.84 X 10-is rag. for an average tem- perature of 21.5C. These values are 10 per cent too low, since it was believed, at the time the experiments were made, that 2 per cent oxygen was the point at which dimming occurred. In order to check this method I have recently made determinations of oxygen consumption in the Thunberg-Winterstein respirometer as used by Fenn ~1927) for experiments on oxygen consumption by nerve.2 The two chambers were of approximately 22 cc. capacity and the capillary held 0.403 gm. of mercury in a length of 153 ram. Since the oxygen consumption in this apparatus is twice the volume movement of the capiUary, each ram. movement of the oil drop in the capillary was equivalent to the consumption of 0.000388 cc. 02. The chambers contained small vessels for the solution of KOH to absorb CO2. Two cc. of bacterial emulsion in sea water was placed i~ one chamber and 2 cc. sea water was placed in the other, both in equilib- rium with air. The whole apparatus was immersed in a thermostat of running sea water at 21C. which changed less than 0.01C. over a period of 2 hours. The readings of the oil droplet movements plotted against time are given in Fig. 1, together with three determinations of the time for another sample of the same emulsion of luminous bacteria to dim, when standing undisturbed at the same temperature. From Fig. 1 it will be seen that the rate of oxygen consumption is practically independant of rate of shaking and that 2 cc. of bacterial emulsion used 0.0272 cc. 02 in 1950 seconds or 0.0000139 cc. 02 per second. One cc. of emulsion would use 0.00000695 cc. per second. Over the same time interval, at 21C., it took 12.5 minutes or 750 seconds (time indicated by arrows) for the luminescence of a similar bacterial emulsion to dim. At 21C. each cc. of sea water will dis- 21 am greatly indebted to Dr. W. O. Fenn for the micro respirometer used in these experiments and to Mr. C. S. Shoup for growing the luminous bacteria and for assistance with the experiments. E. NEWTON HARVEY 471 solve 0.0052 cc. O~ (,Fox, 1909), at least 99.5 per cent of which is con- sumed when dimming occurs. Hence the bacteria in 1 cc. sea water emulsion used 0.0052 - 750 or 0.00000693 cc. O~ per second, a value in perfect agreement with the micro respirometer. I conclude that the dimming method gives a very good index of the oxygen consump- tion of the bacteria. It is interesting to compare the oxygen consumption of luminous bacteria with that of other bacteria. Of the numerous papers on 7 // // / / / / i/2,m. / 13Ira. ~,5~. io. o I.oo 11.7o 11, 0 11.so n. o 1I. o Fig. 1. Readings of index drop scale of micro respirometer in cm. plotted against time in minutes. Below the mark, (A), the respirometer was shaken 98 times per minute; above, (B), at 120 times per minute. The horizontal arrow lines indicate the times for bacterial emulsions to use dissolved oxygen, as determined by the dlmming method. respiration of bacteria (cf. Stephenson and Whetham (1924), Novy and Sonle (1925), Brooks (1918-1922), Callow (1924) and Ptttter (1924)), only Callow and Piitter give values which can be properly compared, namely, oxygen consumption per weight or volume of bacteria. The luminous bacterium used by me in efficiency studies was a cylinder averaging 2.2g long by 1.1g in diameter with rounded ends. Its surface area was 7.6~~ and its volume 1.695~L When 472 OXYGEN CONSUMPTION OF