AN INTERFACIAL TENSIOMETER FOR UNIVERSAL USE.

du Noüy PL. · 1925

Read AN INTERFACIAL TENSIOMETER FOR UNIVERSAL USE. by du Noüy PL. (1925) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2140742.txt.

Introduction

Lecomte du Noüy, at The Rockefeller Institute for Medical Research, described a new instrument in a 1925 paper: an interfacial tensiometer for universal use. Interfacial tension is the skin-like pull where two liquids meet. Older methods measured pure liquids well, but the slow change of tension as substances adsorb at the boundary had gone unstudied for lack of technique.

His instrument reads interfacial tension in a few seconds, in any laboratory, to a fine degree of accuracy. It adapts the ring tensiometer his laboratory had introduced six years earlier. Since the ring pulls only upward, the design had to be reworked to reach measurements the older form barred. The paper gives the device and its handling.

Catalog record

CREATORdu Noüy PL.
YEAR1925
COLLECTIONPAPERS
FORMATTXT
FILE SIZE9 KB
LICENSEPublic Domain
RIGHTSPUBLIC DOMAIN
SOURCEEurope PMC

Source: https://europepmc.org/articles/PMC2140742

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

AN INTERFACIAL TENSIOMETER FOR UNIVERSAL USE By P. Lecomte du Noüy Published in: The Journal of General Physiology DOI: 10.1085/jgp.7.5.625 AN INTERFACIAL TENSIOMETER FOR UNIVERSAL USE. BY P. LECOMTE Du NOOY. (From the Laboratories of The Rockefeller Institute for Medical Research.) PLATE 5. (Acceptedfor publication, April 6, 1925.) The important and fundamental works of Quincke, Hardy, McC. Lewis, Morgan, and lately Harkins and his collaborators have thrown much light on the behavior of liquids at interfaces, and it may seem hardly necessary to develop a new method in order to study this phenomenon, as those existing have reached a high degree of accuracy. However, if the values of the interfacial tensions of pure liquids have been well established by these investigators and others, the changes of the interfacial tension due to adsorption in function of time--a phenomenon similar to that first studied in our laboratoryl--have not, to our knowledge, been studied so far, for lack of proper tech- nique. Consequently, considering the number of new phenomena which were brought to light by the use of the tensiometer first de- scribed in this Journal 6 years ago2we thought it might be of interest to devise a similar instrument with which measurements of interracial tension could be made in a few seconds, conveniently, in any labora- tory, to 0.1 dyne. Our first idea was to utilize the tensiometer as it actually exists on the market, with perhaps a slight modification of the platinum ring. However, as the ring can only be pulled upwards, it limits the measurements for water interfaces, to liquids floating on water; i.e., having a specific gravity < 1. In order to render the instrument universal, it was decided to fix the ring to a rigid support, so that it could be pressed down by means of the torsion wire, as well as pulled xdu Nbfiy, P. L., Papers I-X and XII, J. Exp. Mad., 1922-25,xxxv-xli; Paper XI, J. Gen. Physiol., 1923-24,vi, 625. 2du Notiy, P. L., 3".Gen. Physiol., 1918-19,i, 521. 625 The Journal of General Physiology -- ~.ll ~_..~r r..) i I I I o .~~. I ~ I" l , ~ I l'--* ~0 0 I .......... 0~ ............. q ~ ~, gz~ I I -E E _t. ...... O.q ...... ", .a_ . . . . . ~g ..... i . ~ . . . . . I , ! ' I 626 B P. LECOMTE DU NOUY 627 up. This rigid support is kept in its perpendicular position by means of an articulated parallelogram, K1F1K2F2as seen in Text-fig. 1. The length of both horizontal arms can be adjusted so as to change the moment of the force applied to the ring, and to make the instrument direct reading. The balance of the whole moving system is grossly obtained by a counterweight, B, and the finer adjustment of the zero is realized, as in the ordinary tensiometer, by twisting more or less the end of the torsion wire. The instrument is standardized with weights, in the usual way by considering that the formula M.g .7= 2L in which M = mass in gin. (arbitrary) placed on the ring, g = 981, L = mean length of circumference of ring (6 cm., for instance), gives a value "r which must be the figure read on the dial, when the equilib- rium is attained. In case the figures do not coincide, the length of both arms, the upper one, K2, and the lower one, KI is slightly in- creased or shortened, according to the difference. The weights are then removed and the vernier is brought back to zero by means of the knob. If, in this position, the needle E on the lower arm, does not coincide with the index line on the post D, it is set by means of the torsion wire, and the operation must be repeated with weights. It takes usually less than 10 minutes to standardize the instrument perfectly. When this is done, it is, of course, standardized not only for upward pull (vernier on upper part of the scale) but also for downward push (vernier on lower part of the scale) and the readings are identical in both ways. The scale is graduated throughout the circumference of the dial. A few measurements were taken with substances studied by Harkins, Brown, and Davies (drop method).3 No attempt was made to secure pure liquids, our only aim being to check the soundness of the method. As Harkins and his collaborators took special pains in order to secure absolutely pure materials the discrepancies found Harkins, W. D., Brown, F. E., and Davies, E. C. H., J. Am. Chem. Soc., 1917, xxxix, 356. 628 INTERFACIAL TENSIOMETER between their values and the tensiometric values may be accounted for in this way for the substances spreading on water (Table I). However, the values disagree entirely for the liquids which do not spread on water, namely those having an interfacial tension greater TABLE I. Surface Tension and Interracial Tension agains~Water. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Liquid. Chloroform... Isoamyl alcohol Octyl alcohol..... Benzyl alcohol.. Ethyl iodide... Ethyl ether. Ethyl phthalate... Ethyl carbonate... Oleic acid. Benzene. Toluene .... m-xylene.. Castor oil. Olive oil... ]Dimethyl aniline. Diethyl aniline.. Turpentine.... "Non-spreading Carbon bisulfide............. liquids," accord- Paraffin oil.................. ding to Harkins. Carbon tetrachloride......... I~romoform................. Liquid petrolatum Squibbs... C. 25.0 27.5 27.9 +0.4 1.526 '123"524'2 4.4 --19.8 0.825 25.0 28.6 10.8 --17.8 0.837 25.043.3 4.8 --38.51.023 25.0 32 .3 36.~ +4.31.944 23.018.010.g --7.1 0.718 25.040.8 16.4 --24.4 1.126 25.029.~ ll.g --18.1 0.978 25.0 34.2 12.~ --21.4 0.708 25.0 29.0 32A +1.30.880 25.0 28.0 32.,= +4.5 0.882 23.0 30.0 35.( 9.878 23.0 36.4 15.~ C) .950 23.~ 33.0 17.( --16.01 26.G!38.4 21 .( --18.9iD.955 I 25.035.421., --14.1 25.0 29.2 13., --15.5 --0.2 1.259 +15.0 0.850 +12.0 1.608 -12.0 +16.0 than the difference between the surface tension of water and that of the liquid. In this case, no tension is greater than the sum of the other two, and a triangle of forces is possible and real, Nevertheless, and without questioning the accuracy of Harkins' values for the interracial tension between water and this special class P, LECOMTE DU NO~ 629 4~ eq co oo ,4,4 ~q cq e~ e~ oo e~ oO Lt~ * < r o "~ e~ 630 INTERFACIAL TENSIOMETER of substances, it might be pointed out that Quincke, 4using a catheto- metric method, gave, for the interfacial tension water-CS2, the value 42.6 dynes. As he finds 82.5 for the surface tension of water, while we find 72.8, one might think that it is permissible to reduce this value 82.5 42.6 in the ratio ~ and one obtains 37.4. Our value for water- CS2 is 33.8, and that of Harkins, 54.09. Quincke's method seems quite reliable, and his figures are in good agreement with Harkins' and ours for water-chloroform (26.5 corrected as above) and water- olive oil (18.2). The difference between the values of Harkins' and those of Quincke and ourselves is probably due to the fact that Harkins l~es 36 Wc~ep-ZS2 o. 35 .~o 34 4.a aa 31 5- J ,,~f L f- 3o * f

Read the complete text