Read AN EXPERIMENTAL STUDY OF DIATHERMY : VI. CONDUCTION OF HIGH FREQUENCY CURRENTS THROUGH THE LIVING CELL. by Christie RV. (1928) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2131452.txt.
Introduction
Ronald Christie, at the Hospital of The Rockefeller Institute for Medical Research, wrote part six of the diathermy study series in 1928. Diathermy heats tissue with high frequency currents. Earlier parts dealt with whole limbs and organs. This part asks a finer question: does the current pass through the living cell itself, or only around it?
Christie describes a method to measure the relative impedance, the electrical opposition, of living cells to these currents. The current does enter the cell, so heat is made inside cells as well as between them. A small part of the cell's impedance makes no heat. He also warns that saponin raises the conductivity of a salt fluid, so it spoils such measurements on living material.
Catalog record
| CREATOR | Christie RV. |
|---|---|
| YEAR | 1928 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24 KB |
| LICENSE | Public Domain |
| RIGHTS | PUBLIC DOMAIN |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
AN EXPERIMENTAL STUDY OF DIATHERMY By Ronald V. Christie Published in: The Journal of Experimental Medicine DOI: 10.1084/jem.48.2.235 ABSTRACT 1. A method is described for measuring the relative impedance of living cells to diathermy currents. 2. The diathermy current penetrates the living cell, and heat production is intracellular as well as extracellular. 3. A small proportion of the impedance of living cells to the diathermy current seems not to lead to the production of heat. 4. Evidence is given that the addition of saponin produces an appreciable increase in the conductivity of an electrolyte. Its use is therefore contraindicated when electrical measurements are being made on biological material. 5. The currents used in diathermy behave as do high frequency currents of the pure sine wave form in respect to their passage through biological material. AN EXPERIMENTAL STUDY OF DIATHERMY. VI. CO~W~cTION OF HIGH FREQUENCY CURRENTS THI~OUGHTHE LIVING CELL. BY RONALD V. CHRISTIE, M.B., CraB. (From the Hospital of The Rockefeller Institute for Medical Research.) (Received for publication,.May 24, 1928.) In this paper an attempt will be made to correlate the investigations of biophysicists with those questions which are of fundamental impor- tance in a study of diathermy. A survey of the literature shows that the intimate relationship of these fields has not been appreciated. Biophysicists on the one hand have paid little attention to the phe- nomenon of heat production with the passage of high frequency cur- rents, while those studying diathermy have neglected the problem of cellular conduction and penetration. It is obviously of great impor- tance to know whether the diathermy current passes through the living cell, and if so, what are the effects produced. The only constant effect which is known to be produced by high frequency alternating currents is that of heat production. The chemical effects of electroly- sis disappear as the alternations exceed a frequency of 5,000 to 10,000 per second (1). The explanation for this fact lies in the rapidity of the reversal of the current which does not allow the chemical action of one phase to manifest itself before it is neutralized by the opposite phase (2). The absence of any exciting influence on the tissues through which the current passes is probably analogous to this absence of chemical effect. If the high frequency current is rectified so that it is not alternating in character, electrolysis and muscle excitation will be produced, even if the frequency of interruptions be as high as 500,000 per second (3). The complexity of living tissue makes determinations extremely difficult of the actual course and means of transportation of the current through it. Philippson (4), Fricke and Morse (5), and McClendon (6), in their work on muscle, liver, and blood cells, have shown that as the frequency of alternations is increased the impedance of the living cell decreases, meaning by impedance the sum of all the various hindrances to the passage of the current. At a frequency of 105 to 107 cycles per second a point is reached where the impedance of living and dead cells is in close agreement. Beyond this frequency, according to these authors, the 235 236 DIATHER~I, VI current passes in part at least through the cell, and not wholly through the extra- cellular fluid, as was formerly supposed. The red blood cell is surrounded by a very efficient dielectric layer, equal in thickness to a layer composed of approxi- mately 20 to 30 carbon atoms, and allowing little or no penetration of ions. The interior of the cellhas a coraparatively low resistance, equivalent to a 0.17per cent NaCI solution. The ,cell, therefore, acts as a condenser, which transmits the current by its capacitance. In the living body the various fascial layers also act as dielectrics (7) of varying degrees of efficiency. R, D G G R, R~ R~ R~ R, FIG. 1. Diagrammatic representation of the passage of highfrequencycurrents through the li~.ng cell. R1--Resistance of extracellular fluid. R~--Resistance of cell interior. R~---Dielectricloss. R4--Condenser leak. C --Capacitance of cell. D --Dielectric layer surrounding cell. It will be realized that the passage of high frequency currents through the living body is an extremely complex phenomenon. The whole system consists of resistances and capacitances, both in parallel and in series, some of which are stationary and some in motion. Fig. 1 represents in diagram the passage of the current through a single unit of this system--namely, the living cell. Even this representation is, of course, too simple, since the various phases in the colloidal system we call protoplasm must influence the passage of the current within RONALD V. CHRISTIE 237 the cell (8, 9) and the protoplasm itself is constantly changing in conductivity (10). One would expect these general principles to be applicable to the diathermy current. However, there are several differences between the currents used by the investigators mentioned and those used in diathermy which might render such an application fallacious. The diathermy current consists of pulses of impressed discontinuous oscil- latory trains which probably contain many harmonics. This type of current is not necessarily comparable to a high frequency current of the pure sine wave form. Also, impedance measurements with cur- rents of low and high voltage are not necessarily comparable (11). There are two characteristics of the passage through living cells of low voltage high frequency alternating currents of the pure sine wave form. These, as described by the authors referred to, manifest themselves in the fact that the impedance is not changed when the cell is broken down by lysis, and in the fact that with increase of cellular concentration the impedance increment is less than that found with continuous currents. The experiments described in this paper were planned for the pur- pose of finding out whether these two characteristics hold true with the currents used in diathermy. EXPERn~[RNTAL. Details of the apparatus used to produce the high frequency alter- nating current have been described elsewhere (12). The oscillatory current generated by the discharge of the condenser across the spark gap is of high voltage but low amperage. Owing to the high decre- ment of the circuit the oscillations are in the form of a series of discon- tinuous trains, each train being damped down before the next train commences. The frequency is 1.25 x 10s but the oscillations are not of the pure sine wave form, as harmonics are probably present. Since it is impossibleto make any accurate impedance measurements by the bridge method with this type of current, we were forced to approach the subject from a somewhat different angle from that which has been adopted by the investigators just mentioned. The experi- ments about to be described naturally fall into two groups, more or less independent of each other. They will, therefore, be described separately. 238 DIATHERMY. Vl I. Direct Measurement of Heat Production in Blood and Serum. The heat produced in blood and serum by the passage of a known quantity of current was measured by placing the blood or serum in a specially constructed glass cylinder, so arranged that temperature measurements could be made while the current was passing through it. The material used was defibrinated sheep blood, obtained fresh from the slaughter house. The cell volume