STUDIES IN EXPERIMENTAL EXTRACORPOREAL THROMBOSIS : I. A METHOD FOR THE DIRECT OBSERVATION OF EXTRACORPOREAL THROMBUS FORMATION.
Rowntree LG, Shionoya T. · 1927
Read STUDIES IN EXPERIMENTAL EXTRACORPOREAL THROMBOSIS : I. A METHOD FOR THE DIRECT OBSERVATION OF EXTRACORPOREAL THROMBUS FORMATION. by Rowntree LG, Shionoya T. (1927) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc2131252.txt.
Introduction
Leonard Rowntree and Takuji Shionoya, at the Mayo Clinic in Rochester, Minnesota, opened a 1927 series on clotting outside the body. Postoperative lung embolism, a clot that travels to the lungs, drove the work, since it caused a clear share of deaths after surgery at their clinic. Part one presents a method, not yet results on causes.
Blood is run through an artificial loop outside the body while staying alive in the circuit, so clot formation can be watched directly. Many conditions in the loop can be held or changed at will. The setup also lets the team study white clots and fibrin deposits apart from each other. The two may form as separate processes, the authors note.
Catalog record
| CREATOR | Rowntree LG, Shionoya T. |
|---|---|
| YEAR | 1927 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 13 KB |
| LICENSE | Public Domain |
| RIGHTS | PUBLIC DOMAIN |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
STUDIES IN EXPERIMENTAL EXTRACORPOREAL THROMBOSIS By Leonard G. Rowntree, Takuji Shionoya Published in: The Journal of Experimental Medicine DOI: 10.1084/jem.46.1.7 ABSTRACT A new method has been described for the study in vivo of thrombus formation in blood circulating extracorporeally in an artificial loop. This method permits of control of many factors, and hence of intensive study of thrombus formation under many and varied conditions. It admits of separate study of the formation of white thrombi and of the deposition of fibrin, which may apparently be independent processes. STUDIES IN EXI~]~RIMENTAL EXTRACORPOREAL THROMBOSIS. I. A METHOD FOR THE DIRECT OBSERVATION OF EXTRACORPOREAL THROMBUS FORMATION. BYLEONARDG. ROWNTREE,M.D.,AI~ TAKUJISHIONOYA.* (Fromthe Division of Medicine, Mayo Clinic, and the Mayo Foundation,Rochester, Minnesota.) (Receivedfor publication,April 6, 1927.) Pulmonary embolism is one of the problems still a challenge to medi- cine and surgery. In the Mayo Clinic, the necropsy records show that it has been responsible for 7.3 per cent of the postoperative deaths during the last 10 years. Its annual toll throughout the world must be very large, and is probably much greater than is generally accepted, or than most statistics indicate, since pulmonary embolism is readily overlooked at necropsy unless sought for as a routine and specifically. Because of its important bearing on surgical mortality (2-11) we are making a study of thrombosis with the hope that eventually some means may be found whereby postoperative pulmonary embolism may be avoided or prevented. In connection with this problem, one of us recalls some earlier studies carried on with John J. Abel, in which a dialyzing apparatus or an artificial kidney was used for the removal of diffusible substances from the circulating blood of living animals. In those experiments it was necessary to combat thrombosis constantly despite the fact that hirudin was employed in generous quantities as an anticoagulant. From this experience, it was thought that a similar, but simpler, apparatus might be employed advantageously in the study of the various stages of formation of thrombi, particularly that of white thrombi. *FeUowof the RockefellerFoundation. 7 8 EXTRACORPOREAL TIIROM'BOSIS. I Principle of the Method. The method is simple: it consists in the introduction into the cir- culation of an extracorporeal vascular loop. By means of a cannula, the artery of the animal is attached to a collodion dialyzing tube, immersed in physiologic solution of sodium chloride, or other form of solution, and the blood is returned to the animal's body by another cannula attached to the vein. Before the instrument is attached to the vessds, the tubes and cannulas are completelyfilled with a solution of sodium chloride which approximates in its salt content the plasma of the animal, and this fluid is displaced into the body when the circu- lation through the apparatus is established. During the experiment, the blood flows in a perfectly enclosed sys- tem and is returned to the body within a few seconds without having been exposed to contact with the air. On the way, it passes through the collodion tube which permits of an interchange of diffusible sub- stances between the blood and the fluids in the outside container. Since the inner surface of the apparatus is a foreign surface, coagula- tion occurs rapidly in the normal animal, within 4 to 10 minutes, but coagulation of the blood may be delayed or prevented by paraffining the tubes or by the previous injection of anticoagulants, such as heparin and hirudin, into the vein. Despite the presence of these anticoagulants, white thrombi are formed and thrombosis eventually occurs. The rate of thrombus formation can be influenced by various substances introduced into the circulation directly, or indirectly, and especially locally by dialysis through the collodion membrane, and the factors affecting each stage of clot formation may thereby be analyzed and assayed. The apparatus lends itself readily to the study of the influence of the mechanical, physical and chemical factors affecting the process of thrombosis. The experiments are carried out under com- plete trichloro-tertiary-butylalcohol anesthesia and are usually inter- rupted within 3 or 4 hours. The proportion of blood in the extra- corporeal loop (about 2 cc.) is practically negligible so far as the physiology of the circulation of the animal is concerned. LEONARD G. ROWNTREE AND TAKUJI SHIONOYA The Apparatus. The apparatus (Text-fig. 1) is simply an artificial circulatory loop permitting of extracorporeal blood flow. It consists of two parts con- nected by a collodion tube, which is immersed in a tube used as a container for dialyzing solutions. A glass frame holds the apparatus in place. The centrifugal and centripetal parts of the apparatus are attached respectively to the carotid artery and jugular vein. For purposes of handling and cleansing, each part is made in three sections, which are connected by means of rubber tubing. An ordinary arterial glass cannula, a, (about 4.5 cm. in length) is attached to the vessel and connected with the side tube b, which is about 6 cm. long and curved slightly to facilitate its connection with the corner tube c (5 cm.), which is curved in two directions, horizontally to approach the collodion tube g, which connects it with the other half of the apparatus, and down- ward to provide for immersion of the collo- dion membrane in the solution of the out- side container h. The side tube and corner tube are paraffined. The collodion tube is attached to the two corner tubes by liga- tures. The containing jacket is a short, TExT-FIG. 1. Extracor- stoppered test-tube with an opening in the poreal loop. side, which permits the immersion of the collodion tube in the solution of the dialyzing system. When the experiment is in progress, the blood flows from the artery through the cannula, side tube and corner tube of the arterial part into the collodion tube, and then into the corner tube d, side tube e, and cannulaf, of the centripetal part back to the veins of the animal. Technic of the Experimenl. Rabbits, dogs or cats are suitable for such experiments, but through- out all our experiments rabbits have been employed; compared with dogs, they are more economical in the use of the anticoagulants. 10 EXTRACORPOREAL THROMBOSIS. I Anesthesia is induced by the intraperitoneal injection of a saturated solution of trichloro-tertiary-butylalcohol in olive oil (from 1.5 to 2 cc. for each kilo of body weight). The apparatus is prepared, the glass side tube and corner tube paraffined, the collodion tube tied in place and the whole apparatus filled with physiologic sodium chloride solution. The cannulas are introduced in the usual way, particular care being taken to produce as little trauma as possible. The vessels are clamped gently and carefully, to preserve, so far as possible, the integrity of the intima. With the cannulas tied in place, the cut wounds of the vessels are outside of the circuit, and hence, little, if any tissue juice or thromboplastic substance finds its way into the circulation in the extracorporeal loop. All the experiments are conducted under prac- tically identical conditions. If anticoagulants are administered, un- usual care must be exercised in the isolation and ligation of all vessels. This is necessary in the absence of dotting resulting from the anti- coagulants, otherwise large quantities of blood may be