Excess circulating angiopoietin-2 may contribute to pulmonary vascular leak in sepsis in humans.
Parikh SM, Mammoto T, Schultz A, Yuan HT, Christiani D, Karumanchi SA, Sukhatme VP. · 2006
Read Excess circulating angiopoietin-2 may contribute to pulmonary vascular leak in sepsis in humans. by Parikh SM, Mammoto T, Schultz A, Yuan HT, Christiani D, Karumanchi SA, Sukhatme VP. (2006) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc1334221.txt.
Introduction
Parikh and co-authors linked a vessel protein to lung leak in sepsis in 2006. Sepsis can trigger acute respiratory distress syndrome, a deadly lung failure. Vessel leak drives that failure, but its mediators were unclear. Angiopoietin-2 blocks a vessel-stabilizing receptor and was the suspect.
Blood levels of angiopoietin-2 ran significantly higher in sepsis patients. The elevation was clearest in patients with impaired oxygenation. Serum from those patients disrupted vessel cell architecture in dishes. Mouse and cell studies backed the human pattern. Parikh names angiopoietin-2 as a contributor to septic leak.
Catalog record
| CREATOR | Parikh SM, Mammoto T, Schultz A, Yuan HT, Christiani D, Karumanchi SA, Sukhatme VP. |
|---|---|
| YEAR | 2006 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 71 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Excess Circulating Angiopoietin-2 May Contribute to Pulmonary Vascular Leak in Sepsis in Humans By Samir M Parikh, Tadanori Mammoto, Aylit Schultz, Hai-Tao Yuan, David Christiani, S Ananth Karumanchi, Vikas P Sukhatme, Peter J Barnes Published in: PLoS Medicine DOI: 10.1371/journal.pmed.0030046 ABSTRACT Abstract Background Acute respiratory distress syndrome (ARDS) is a devastating complication of numerous underlying conditions, most notably sepsis. Although pathologic vascular leak has been implicated in the pathogenesis of ARDS and sepsis-associated lung injury, the mechanisms promoting leak are incompletely understood. Angiopoietin-2 (Ang-2), a known antagonist of the endothelial Tie-2 receptor, was originally described as a naturally occurring disruptor of normal embryonic vascular development otherwise mediated by the Tie-2 agonist angiopoietin-1 (Ang-1). We hypothesized that Ang-2 contributes to endothelial barrier disruption in sepsis-associated lung injury, a condition involving the mature vasculature. Methods and Findings We describe complementary human, murine, and in vitro investigations that implicate Ang-2 as a mediator of this process. We show that circulating Ang-2 is significantly elevated in humans with sepsis who have impaired oxygenation. We then show that serum from these patients disrupts endothelial architecture. This effect of sepsis serum from humans correlates with measured Ang-2, abates with clinical improvement, and is reversed by Ang-1. Next, we found that endothelial barrier disruption can be provoked by Ang-2 alone. This signal is transduced through myosin light chain phosphorylation. Last, we show that excess systemic Ang-2 provokes pulmonary leak and congestion in otherwise healthy adult mice. Conclusions Our results identify a critical role for Ang-2 in disrupting normal pulmonary endothelial function. INTRODUCTION Sepsis is characterized by a systemic inflammatory response to a microbial pathogen. In the United States, this illness accounts for 2%–3% of all hospital admissions (∼650,000 per year to major hospitals), carries a mortality of ∼30%, and has estimated annual direct costs in excess of $16 billion [1]. Although the mortality associated with sepsis has declined in the past 20 years [2], it remains a common and deadly condition. Among individuals with sepsis, those who develop shock and multi-organ dysfunction are at greatest risk of death [3]. Capillary permeability is a tightly regulated feature of microcirculation in all organ beds and is fundamentally altered in sepsis, resulting in net extravasation of fluid out of the vascular space and into tissues. A dramatic manifestation of this phenomenon is acute respiratory distress syndrome (ARDS), a complication that occurs in up to 40% of patients with sepsis and is marked by leakage of fluid out of pulmonary capillaries and into alveolar septa and air spaces [4]. Excess extravascular fluid in the lung impairs gas exchange across the alveolar membrane and decreases lung compliance. ARDS associated with sepsis has been correlated with adverse clinical outcomes, including ∼40% mortality [5–7]. Endothelial barrier integrity is thought to be a balance between (1) contractile forces within endothelial cells (ECs) that permit paracellular leakage by creating intercellular gaps and (2) adhesive forces between ECs that restrict such gaps. Myosin light chain (MLC), in its phosphorylated form (MLC-p), mediates contraction in a wide variety of cells, including the microvascular endothelium. An increase in contractile force within ECs—via MLC-p—is associated with increased permeability [8,9]; conversely, blockade of MLC-p reduces trans-endothelial permeability [10]. Angiopoietin-1 (Ang-1) and angiopoietin-2 (Ang-2) are peptide ligands that bind the Tie-2 receptor tyrosine kinase found primarily on ECs. They were first identified as an agonist/antagonist pair necessary for embryonic vascular development [11,12]. Ang-1 appears to promote vessel stability [12,13] by recruiting pericytes to nascent blood vessels [14] and preserving cell–cell contacts [15]. Ang-1 may also have an anti-inflammatory action by signaling the down-regulation of surface-adhesion molecules such as VCAM-1 and E-selectin [16]. Ang-1, expressed in supraphysiologic concentrations, appears to function as an anti-permeability agent in rodent dermal capillaries [17]. Disruptions in the Tie-2 signaling pathway can occur in developmental lung disorders [18], and expression of Tie-2 in quiescent adult tissues is highest in the lung [19,20]. Together these reports suggested (a) that an imbalance in Tie-2 signaling could arise in the inflammatory milieu of sepsis, and (b) that, should such an imbalance arise, the lung might be preferentially affected. We therefore hypothesized that excess Ang-2 signaling may occur in sepsis, promoting pulmonary vascular leak through up-regulation of MLC-p. We explored this question in several settings: (1) humans with sepsis in whom circulating Ang-2 levels were measured, (2) EC monolayers in which signaling and structural responses to sepsis serum from humans and recombinant human Ang-2 were assessed, and (3) a rodent model in which vascular leak was quantified. METHODS Patients Every weekday during a 2-mo period, all patients admitted during the preceding 24 h to the medical intensive care unit at Beth Israel Deaconess Medical Center were screened for study eligibility. Participants were identified by the parameters used to define sepsis [21]. Evidence of infection (e.g., positive cultures, typical clinical syndrome) must have been accompanied by two of the following four criteria: (1) temperature < 36 °C or > 38 °C; (2) heart rate > 90 bpm; (3) respiratory rate > 20 bpm or PaCO2 < 32 mmHg; (4) white blood cell count > 12,000 cells/mm3, <4,000 cells/mm3, or >10% immature forms. In a prospective fashion, discarded serum samples and clinical data were collected on this cohort as well as from a randomly selected control group of patients hospitalized on the general medical service with a variety of illnesses that did not meet criteria for sepsis. All identifying information was removed; study specimens from patients and clinical data were encoded to protect the privacy of patients. Serum collected from the clinical laboratory was aliquoted in a sterile fashion and stored in cryo-vial tubes at −80 °C. The institutional review board of Beth Israel Deaconess Medical Center approved this study. ELISA Ang-2 levels were measured in serum samples from patients by sandwich ELISA using the reagents and protocol supplied with the human Ang-2 ELISA kit (R&D Systems, Minneapolis, Minnesota, United States). Preliminary experiments confirmed the stability of Ang-2 in serum for 6–12 h at room temperature as well as its stability through several freeze–thaw cycles. Chemicals We purchased human recombinant Ang-1 and Ang-2 from R&D Systems. The RhoA-associated protein kinase inhibitor Y27632 and endothelial cell myosin light chain kinase (EC MLCK) inhibitor ML-7 were purchased from EMD Biosciences (San Diego, California, United States). Other reagents used in the experiments were obtained from Sigma (St. Louis, Missouri, United States). Animals Female FVB mice (obtained from Charles River, Wilmington, Massachusetts, United States) weighing 18–25 g were used throughout the study. All protocols were approved by the Beth Israel Deaconess Medical Center Animal Committee. They were acclimated to the animal facilities for at least 1 wk before the beginning of any experiment. Cell Culture Human microvascular endothelial cells (HMVECs) from neonatal dermis (Cambrex Bio Science, Walkersville, Maryland, United States) were cultured in EBM-2 (Cambrex Bio Science) supplemented with 5% fetal bovine serum (FBS) and growth factors according to the manufacturer's instructions. Serum starvation was performed by incubation in 0.25% FBS/EBM-2 for 24 h. Evans Blue Permeability Assay Mice were injected with 10 μg of Ang-2 or vehicle intraperitoneal, and, after 16 h, were anesthetized with Avertin (2,2,2-Tribromoethanol). 2% Evans blue (50 μl) was then injected into the retro-orbital sinus. (In preliminary experiments with control mice, n =