A simple technique for quantifying apoptosis in 96-well plates.
Ribble D, Goldstein NB, Norris DA, Shellman YG. · 2005
Read A simple technique for quantifying apoptosis in 96-well plates. by Ribble D, Goldstein NB, Norris DA, Shellman YG. (2005) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/europmc-pmc1142306.txt.
Introduction
Ribble, Goldstein, Norris, and Shellman present a simple plate-based method to count dying cells in this 2005 paper. Apoptosis is programmed cell death, a routine measure in biological studies. Existing counting methods involve multiple, sometimes cell-damaging steps and cannot score live, dead, and apoptotic cells at once. False positives add further error.
Their modified stain assay runs entirely in a 96-well plate, a standard lab tray with many small wells. It adapts a classic two-dye method using ethidium bromide and acridine orange. The team compared it with the conventional method on suspension cells and adherent cells, under normal and death-inducing conditions. Results matched the conventional method for both cell types. The authors conclude the plate format keeps accuracy while removing transfer steps that damage cells.
Catalog record
| CREATOR | Ribble D, Goldstein NB, Norris DA, Shellman YG. |
|---|---|
| YEAR | 2005 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| LICENSE | CC BY 4.0 |
| RIGHTS | CC BY |
| SOURCE | Europe PMC |
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A simple technique for quantifying apoptosis in 96-well plates By Deborah Ribble, Nathaniel B Goldstein, David A Norris, Yiqun G Shellman Published in: BMC Biotechnology DOI: 10.1186/1472-6750-5-12 ABSTRACT Abstract Background Analyzing apoptosis has been an integral component of many biological studies. However, currently available methods for quantifying apoptosis have various limitations including multiple, sometimes cell-damaging steps, the inability to quantify live, necrotic and apoptotic cells at the same time, and non-specific detection (i.e. "false positive"). To overcome the shortcomings of current methods that quantify apoptosis in vitro and to take advantage of the 96-well plate format, we present here a modified ethidium bromide and acridine orange (EB/AO) staining assay, which may be performed entirely in a 96-well plate. Our method combines the advantages of the 96-well format and the conventional EB/AO method for apoptotic quantification. Results We compared our method and the conventional EB/AO method for quantifying apoptosis of suspension cells (Jurkat) and adherent cells (A375) under normal growth and apoptosis-inducing conditions. We found that our new EB/AO method achieved quantification results comparable to those produced using the conventional EB/AO method for both suspension and adherent cells. Conclusion By eliminating the detaching and washing steps, our method drastically reduces the time needed to perform the test, minimizes damage to adherent cells, and decreases the possibility of losing floating cells. Overall, our method is an improvement over the currently available techniques especially for adherent cells. BACKGROUND Apoptosis, a type of programmed cell death, is an active process. It is a normal component of the development and health of multicellular organisms. The study of apoptosis is an important field of biological inquiry since a deficiency or an excess of apoptosis is one of the causes for cancers, autoimmune disorders, diabetes, Alzheimer's, organ and bone marrow transplant rejection, and many other diseases. Accordingly, a quick and easy assay for quantification of apoptosis would be very useful for many biological researchers. Currently, methods available to help detect apoptosis in vitro include several morphological staining methods (such as ethidium bromide and acridine orange (EB/AO) [1,2], DAPI (4; 6-diamidino-2phenylidole) [2], Hoechst staining [2], and etc), Annexin V staining [3-6], DNA ladder [7,8], TUNEL (Terminal deoxynucleotidyl transferase mediated dUTP Nick End Labeling) [9-11], Caspase-3/7 activity [12-16], and ssDNA staining [17-22]. However, these methods have at least one of the following limitations: 1) Involvement of multiple steps All current staining methods, Annexin V, and DNA laddering assays require detaching, washing and transferring the cells. These procedures might damage the cell membranes and change the cell population distribution of live, apoptotic and/or necrotic cells. Procedures with multiple steps also require more time to perform the assay, and more materials allowing for loss of the cells through the procedures. 2) Lack of the ability to quantify live, apoptotic and necrotic cells at the same time DAPI staining, caspase-3/7 activity, DNA laddering, and ssDNA staining methods only detect increase of apoptotic signals, and can not easily quantify percentage of live, apoptotic, and necrotic cells. 3) Non-specific detection The TUNEL assay is widely used for detecting apoptotic cells. However, it has been shown to provide false positive signals in some necrotic cells [18,21,22]. Despite the many characteristics of apoptotic cells analyzed by current methods, chromatin condensation and nuclear fragmentation remain the hallmarks of apoptotic cells [1,23-25]. It has been suggested that as a rule, classification of cell death in a given model should always include morphological examination coupled with at least one other assay [26]. Fluorescence light microscopy with differential uptake of fluorescent DNA binding dyes (such as EB/AO staining) is a method of choice for its simplicity, rapidity, and accuracy. In such an assay, apoptotic index and cell membrane integrity can be assessed simultaneously and there is no cell fixation step, thus avoiding a number of potential artifacts [26]. Acridine orange (AO) permeates all cells and makes the nuclei appear green. Ethidium bromide (EB) is only taken up by cells when cytoplasmic membrane integrity is lost, and stains the nucleus red. EB also dominates over AO. Thus live cells have a normal green nucleus; early apoptotic cells have bright green nucleus with condensed or fragmented chromatin; late apoptotic cells display condensed and fragmented orange chromatin; cells that have died from direct necrosis have a structurally normal orange nucleus [26]. A 96-well plate format is ideal for examining multiple cell types and performing multiple assays while using very small amounts of materials. It is also a suitable format for high throughput drug screening. To overcome the shortcomings of current methods that quantify apoptosis in vitro, and to take advantage of the 96-well plate format, we present here an improved EB/AO staining assay performed entirely in a 96-well plate. RESULTS AND DISCUSSION We modified the conventional EB/AO method by centrifuging the cells in a 96-well plate to bring down all the cells, including floaters, to the bottom of the plate. Using this method, we obtained quantification of live, necrotic, and apoptotic cells for both suspension cells (Jurkat, Figure 1), and adherent cells (A375, Figure 2), under normal growth and apoptosis-inducing conditions that was comparable to the conventional EB/AO method. [Figure: Comparison of a 96-well-based and the conventional EB/AO method for Jurkat suspension cells. Jurkat cells were treated with 6 μM camptothecin for induction of apoptosis. (A) -Images of the cells. Yellow arrows next to "L" point to live cells; white arrows next to "A" indicate apoptotic cells; and red arrows next to "N" indicate necrotic cells. (B) Quantification of untreated live, necrotic, and apoptotic cells. (C) Quantification of live, necrotic, and apoptotic cells treated with camptothecin. p-values from chi-square tests were marked on the bottom of each graph.] [Figure: Comparison of a 96-well-based and the conventional EB/AO method for A375 adherent cells. A375 cells were treated with 6 μM camptothecin for induction of apoptosis. Symbols and labels are used in the same way as in Figure 1.] Figure 1 compares the results from our method and the conventional EB/AO methods for both control and treated Jurkat cells. Figure 1A exemplifies cell morphology obtained using both methods. We note that the definition is sharper by eye through the microscope than in the photos. In addition, the pictures obtained using the conventional method, which uses microscope slides, were sharper than those produced using the 96-well based method. This might be due to the relatively poor optical quality of the plastic bottom of 96-well plates. However, this did not encumber the quantification of live, apoptotic, and necrotic cells using the 96-well based method. Further, if high optical clarity is desirable, one may use glass-bottom 96-well plates to eliminate this possible limitation, or use a microscope with Hoffman modulation contrast to increase the optical quality of the plastic [27]. Determining the live, apoptotic and necrotic cells was comparable between these two methods for Jurkat cells: A) live cells have normal nuclei staining which present green chromatin with organized structures; B) apoptotic cells contain condensed or fragmented chromatin (green or orange); C) necrotic cells have similar normal nuclei staining as live cells except the chromatin is orange instead of green. Overall, quantification of live, necrotic, and apoptotic control and treated Jurkat cells was quite comparable using both methods (Figure 1B and 1C). The chi-square tests showed that the