Variation in surface properties as error sources in dynamic temperature measurements
Akin, Minta · 2026
Read Variation in surface properties as error sources in dynamic temperature measurements by Akin, Minta (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/doe-osti-3028322-variation-in-surface-properties-as-error.txt.
Description
M C Akin of Lawrence Livermore National Laboratory studies a quiet error source in LLNL-TR-2011344, dated September 2025: when temperature is measured fast and from a distance, the surface itself can lie. Optical temperature readings depend on how the surface emits and reflects, and those properties vary with finish, oxidation, and coating. Under dynamic conditions, that variation becomes measurement error.
The report works the problem numerically. Tables sweep surface emissivity settings from five hundredths to nine tenths against true temperatures of 6000 and 7000. The computed apparent readings swing widely, from about 5085 to 6195 in the 7000 rows as the second parameter runs from five hundredths to two tenths. Rows like these are the point: two surfaces at one real temperature can report very different temperatures unless their properties are pinned down.
Catalog record
| CREATOR | Akin, Minta |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 40 KB |
| LICENSE | Public Domain |
| RIGHTS | PUBLIC DOMAIN |
| SOURCE | DOE OSTI |