Radiation effects and noise evolution in NewAthena WFI flight-production sensors
Valentin Emberger, Johannes Müller-Seidlitz, Luisa Ostler, Wolfgang Treberer-Treberspurg, Robert Andritschke, Annika Behrens, Günter Hauser, Peter Lechner, Astrid Mayr, Leonie Sommer · 2026
Read Radiation effects and noise evolution in NewAthena WFI flight-production sensors by Valentin Emberger, Johannes Müller-Seidlitz, Luisa Ostler, Wolfgang Treberer-Treberspurg, Robert Andritschke, Annika Behrens, Günter Hauser, Peter Lechner, Astrid Mayr, Leonie Sommer (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-30169.txt.
Introduction
Valentin Emberger and nine colleagues bombard flight-grade X-ray sensors to predict their end-of-life behavior in orbit. The sensors serve the Wide Field Imager on ESA's NewAthena observatory. Their depleted p-channel transistor design promises very low readout noise. Radiation damage in space could erode that quality steadily. The team measures how noise components evolve under dose.
One module was irradiated with energetic protons at an Austrian accelerator. It stayed biased and cold, running as in flight, throughout the exposure. The dose equals a standard mission equivalent for these sensors. A second module received a similar dose much faster, probing annealing. Ionizing dose effects were tested in a separate run with molybdenum X-rays. Readout noise, dark current, and threshold voltage all shifted measurably. Results are compared with an earlier pre-flight sensor campaign. Required operating temperature and end-of-life state are reassessed accordingly.
Catalog record
| CREATOR | Valentin Emberger, Johannes Müller-Seidlitz, Luisa Ostler, Wolfgang Treberer-Treberspurg, Robert Andritschke, Annika Behrens, Günter Hauser, Peter Lechner, Astrid Mayr, Leonie Sommer |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 33 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.30169
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Radiation effects and noise evolution in NewAthena WFI flight-production sensors Valentin Emberger, Johannes Müller-Seidlitz, Luisa Ostler, Wolfgang Treberer-Treberspurg, Robert Andritschke, Annika Behrens, Günter Hauser, Peter Lechner, Astrid Mayr, Leonie Sommer Abstract The Wide Field Imager (WFI), one of the two instruments on ESA’s next large X-ray observatory NewAthena, is designed for imaging spectroscopy in the 0.2–15 keV range, combining a large field of view with high count-rate capability. Its focal plane is equipped with back-illuminated DEPFET (Depleted p-channel field-effect transistor) sensors that offer high radiation tolerance and provide near Fano-limited energy resolution. Achieving this performance requires an exceptionally low readout noise, with about 3 electrons ENC expected at beginning of life. Consequently, the devices are highly sensitive to radiation-induced changes in noise behavior. In this work, we investigate the impact of both total non-ionizing dose (TNID) and total ionizing dose (TID) on the relevant noise components, including their temperature dependence. A detector module containing a 64 × \times 64-pixel sensor from a flight-production wafer was irradiated with 62.4 MeV protons at the MedAustron accelerator facility in Wiener Neustadt to a total dose equivalent to 2.6 ⋅ \cdot 10 9 10-MeV-protons/cm². The detector was fully biased and operated throughout the irradiation and subsequent measurements, maintaining the nominal operating temperature of 213 K. To study short-term annealing behavior at low temperature, a second, identical module was exposed to a comparable proton dose within a much shorter timescale by exploiting the available high beam flux. TID effects were investigated separately by irradiating another device with 17.4 keV Mo-K α \alpha X-rays to a total dose of 15 Gy. We report the resulting changes in readout noise, dark current, and threshold voltage, and compare them with results from an earlier irradiation campaign using pre-flight sensors. Implications for the instrument’s required operating temperature and its expected end-of-life performance are discussed. a]Max-Planck-Institute for Extraterrestrial Physics, Giessenbachstr 1, 85748 Garching, Germany b]Semiconductor Laboratory of the Max-Planck-Society , Isarauenweg 1, 85748 Garching, Germany c]Univ. of Applied Sciences Wiener Neustadt, Johannes-Gutenberg-Straße 3, 2700 Wiener Neustadt, Austria keywords Athena WFI, DEPFET, Silicon detector, X-ray camera, Dark current, Radiation test, TNID, Displacement damage † † authorinfo: Send correspondence to V. Emberger 1 INTRODUCTION The focal plane of the WFI [ 2 ] instrument for NewAthena [ 5 ] will consist of DEPFET sensors. The current detector design, together with recent results from electrical and performance characterization, is described in Refs. [ 4 , 3 , 16 , 17 ] . As the mission approaches adoption, the WFI team aims to demonstrate the performance of the instrument subsystems under representative environmental conditions. For the WFI camera head, which is centered around a DEPFET sensor, the dominant degradation mechanism in orbit is expected to be an increase in dark current caused by displacement damage from high-energy protons. To limit the resulting radiation-induced noise contribution to acceptable levels, the DEPFET sensors must be operated at low temperatures. The current baseline foresees an operating temperature of 213 K at the beginning of the mission (Beginning of Life, BOL), with the capability to reduce the temperature to 193 K by the end of the nominal mission (End of Life, EOL). This operating range addresses two competing requirements: maintaining a sufficiently high temperature to minimize contamination of the sensor during the early phase of the mission, while keeping the temperature low enough to suppress thermally generated charge in the large sensitive volume of the device. The effects of proton irradiation were investigated using two sensors from an NewAthena flight-production wafer. The irradiation campaign is described in Section 3 . Previous radiation studies have shown that DEPFET sensors respond to TID not only through shifts in threshold voltage but also through an increase in read noise. However, the physical origin of this additional noise contribution has remained unclear. Proton irradiation inevitably introduces both TNID and TID. However, the proton energy spectrum available at irradiation facilities cannot exactly reproduce the spectrum expected in orbit. Consequently, the relative contributions of TNID and TID differ from those encountered in the space environment. Furthermore, the temporal evolution and temperature dependence of the corresponding noise contributions are markedly different. Therefore, a dedicated TID irradiation campaign is required in addition to the proton irradiation study. The TID test, performed with a separate sensor from the flight production, is presented in Section 4 . Since this irradiation introduces only ionizing damage, it allows the effects of TID to be isolated from those of TNID. Combining the results of both irradiation campaigns provides a more complete understanding of the sensor response to the space radiation environment and enables predictions of the detector performance throughout the mission lifetime. A particular focus of both irradiation studies is the identification of the noise components affected by radiation damage and the characterization of their evolution with time and temperature over the relevant operating range. Sections 3.3 and 4.3 discuss the post-irradiation evolution of the individual noise components and assess the detector performance expected for the WFI on NewAthena. 2 THEORY The WFI instrument is supposed to achieve a very low readout noise of \sim 3 electrons Equivalent Noise Charge (e - ENC) across the complete readout chain. There are three main contributors to the total read noise, the detector, the Detector Electronics (DE) and, the Ground Segment (GS): \sigma_{total}^{2}=\sigma_{detector}^{2}+\sigma_{DE}^{2}+\sigma_{GS}^{2} (1) These can be divided into numerous sub components, estimations for each have been derived from measurements or analysis. A detailed budget is presented in Ref. [ 15 ] . Here we focus only on the detector noise that is composed of three components: \sigma_{detector}^{2}=\sigma_{darkcurret}^{2}+\sigma_{depfet}^{2}+\sigma_{asic}^{2} (2) The dark current noise is the shot noise due to the thermal generation of charge carriers that occurs in the silicon bulk of the sensor. It is a crucial component because it is expected to experience the strongest change during the mission. It is equal to the square root of the number of generated electrons per readout cycle. \sigma_{darkcurrentl}=\omega\sqrt{g\cdot t}\,, (3) with frame time t, generation rate g and mean electron hole pair creation energy \omega . Here \omega = 3.71 eV is used [ 14 ] . With the measurement setup in this experiment the detector noise is measured and the three components of the detector noise can be determined individually. When the source to drain voltage of the DEPFET is set to 0 V the current flow from the sensor to the readout ASIC is switched off. The remaining noise measured with the readout system is approximately equal to \sigma_{asic} (with some additional minor contributions of the ADCs and a buffer between the readout ASIC and the ADCs). The dark current noise \sigma_{darkcurrent} is measured by varying the frame time in the range from 0.25 to 9 ms and fitting the measured total noise according to equation 3 . The DEPFET noise is then obtained by subtracting the dark current noise and asic noise from the total detector noise according to equation 2 . Figure 1 : Left: Picture of a detector module like the ones that were used for the irradiation tests. Right: Setup with vacuum chamber that was used. In orbit the dark current noise increases due to lattice defects that are introduced through particle radiation, i.e. the Total Non Ionizing