The Impact of Non-Gaussian Line Spread Functions on Stellar Kinematic Recovery: Consequences for Dynamical Models

David A. Simon 1,2∗ · 2026

Read The Impact of Non-Gaussian Line Spread Functions on Stellar Kinematic Recovery: Consequences for Dynamical Models by David A. Simon 1,2∗ (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-30129.txt.

Introduction

David Simon, writing alone, examines how a spectrograph's line spread function distorts measurements of stellar motion. The line spread function describes how a single spectral line gets broadened by the instrument. Pipelines usually assume that profile is Gaussian in shape. Real integral field spectrographs show profiles with wings or boxy forms instead. Simon asks how much error that mismatch creates.

He tests recovery of stellar kinematics on a mock spectrum. Even at a high velocity dispersion of three hundred kilometers per second, the results shift noticeably. Non-Gaussian profiles cause up to seven percent uncertainty in the dispersion. Higher order shape moments can be biased by about a tenth. Simon's fix matches the template spectrum's profile to the target's profile. That matching cuts the dispersion bias below one percent. A public Python implementation accompanies the method.

Catalog record

CREATORDavid A. Simon 1,2∗
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE74 KB
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2606.30129

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

The Impact of Non-Gaussian Line Spread Functions on Stellar Kinematic Recovery: Consequences for Dynamical Models ∗ E-mail: [email protected] David A. Simon 1,2∗ Abstract The line spread function (LSF) of a spectrograph encodes the inherent broadening of a single spectral line. It is typically reported as a single number, the resolving power R = λ / Δ ​ λ R=\lambda/\Delta\lambda with Δ ​ λ \Delta\lambda the FWHM of the LSF. In standard pipelines for extracting stellar kinematics the LSF is assumed to be a wavelength dependent Gaussian. However, detailed LSF measurements from real integral field spectrographs reveal a variety of shapes, some close to Gaussian, others with large wings or that appear boxy. I have studied the impact that these non-Gaussian LSF profiles have on the recovery of the stellar kinematics of a mock spectrum and find that even in the high dispersion case of 300 km s -1 , there is up to a 7 percent uncertainty in the dispersion due to non-Gaussian LSF profiles. Additionally, higher order Gauss-Hermite moments h 3 h_{3} and h 4 h_{4} can be biased by up to ± \pm 0.1. To resolve this bias, I developed a method to match the LSF of the template spectra to the LSF of a target spectrum when the LSF of either one or both is non-Gaussian and show that it can reduce bias in the dispersion to less than a percent down to the instrumental resolution. A Python implementation of this method has been made publicly available. keywords galaxies: general – galaxies: kinematics and dynamics – instrumentation: spectrographs 1 Introduction 1.1 Background Standard approaches for extracting stellar kinematics from integral field data involve fitting a template spectrum to a galaxy or target spectrum by applying a velocity shift and broadening to the template spectrum (e.g. 8 ; 9 ; 10 ; 59 ; 12 ; 46 ; 35 ). However, kinematics are not the only source of broadening. Another key source is the spectral point spread function, also known as the line spread function (LSF). The LSF encodes the broadening of single spectral lines at each wavelength of the spectrum. In order to ensure that the kinematics measured with a spectral fitting code are accurate, it is necessary to first ensure that the template spectra and target spectrum have the same LSF. The LSF is typically reported as a single number in terms of the resolving power of the spectrograph, defined as R=\frac{\lambda}{\Delta\lambda} (1) where \Delta\lambda is the full width at half maximum (FWHM) of the LSF. Most measurements of stellar kinematics are made assuming that the intrinsic shape of the LSF is Gaussian, and relate the FWHM to the standard deviation of a Gaussian using the relationship \Delta\lambda=2\sqrt{2\ln 2}\sigma_{\lambda}\approx 2.355\sigma_{\lambda} (2) Under this assumption, the LSF of the template spectra is matched to the LSF of the target spectrum by taking a convolution of the form \text{LSF}_{\rm Template}*G=\text{LSF}_{\rm Target} (3) where G is the function that matches the template LSF to the target LSF. In the case that both \text{LSF}_{\rm Template} and \text{LSF}_{\rm Target} are Gaussian, G can be solved for exactly and is a Gaussian with a standard deviation given by \sigma=\sqrt{\sigma_{\rm Target\ LSF}^{2}-\sigma_{\rm Template\ LSF}^{2}} (4) In general this standard deviation is wavelength dependent and is applied to the template spectrum with a wavelength dependent convolution code (see 10 , Algorithm 1). This expression also implies that this matching convolution can only be performed when \sigma_{\rm Target\ LSF}>\sigma_{\rm Template\ LSF} . Otherwise the target spectrum must be broadened to match the template spectrum. 1.2 Origins of the LSF There are strong theoretical reasons to expect that the LSF may not be described as a perfect Gaussian. For slicer-based integral field spectroscopy (IFS), the LSF, to first order, can be described as a convolution of four separate terms: the slit, the diffraction grating dispersion, the instrument PSF (also called the camera PSF), and a pixel wide top hat function (this converts the output to something measured on a pixelated detector). If the slit is uniformly illuminated then the contribution from it is a top hat function with width equal to the slit width (typically 2-3 times the size of a spectral pixel). The case where the slit is not uniformly illuminated gives rise to the so-called classical slit effect and can result in significant uncertainties (e.g. section 2 of 3 ). However, in the case of studies of galaxies and stellar kinematics the slit is likely to be close to uniformly illuminated so this is not likely to be a significant contributor to the LSF shape. Convolving the slit with the pixel top hat then gives a trapezoid. The diffraction grating dispersion is typically a fraction of a pixel wide, and thus small compared to the other terms 1 1 1 Though in some cases, such as for SINFONI, it can be significant ( 22 ) . . The convolution with the instrumental PSF is the last step in determining the (first order) shape of the LSF. For a Gaussian instrumental PSF, this will produce a boxy LSF. For an instrumental PSF with wide wings, this can produce an LSF with wings. Fiber based IFS and lenslet based IFS are similar to this, except the convolution with the slit is replaced by a convolution with the projected fiber core, or a convolution with the exit micro-pupil respectively. These effectively remove any uncertainty from the slit effect. Therefore, in each of the major varieties of IFS there is freedom in the final shape of the LSF depending on the specific characteristics of the instrument (see 4 Sec. 8.2 for more details). 1.3 Empirical LSFs In general, making detailed measurements of the LSF for real instruments is difficult. Integral field spectrographs are typically designed to just satisfy the Nyquist-Shannon sampling criterion ( 40 ; 50 ) , making detailed LSF profiles difficult to measure in a single observation with the spectrograph. Several techniques have been devised to measure detailed LSF profiles. One approach is to take multiple observations of standard spectral lines while manually shifting the diffraction grating by a fraction of a pixel, thus super-sampling the LSF ( 52 ; 30 ; 34 ) . This provides significant control over how much over-sampling is performed, but its feasibility depends on the design of the instrument 2 2 2 29 proposes a method to perform hyperspectral sampling without making any internal modifications to the spectrograph using a Fabry-Pérot etalon. . Another approach is to use slit or line curvature ( 31 ; 30 ; 36 ) . Curvature refers to the fact that single spectral lines (e.g. from calibration lamps), will have different centroid locations within a pixel at different areas on a detector. This is effectively the same as manually shifting the grating though the shift is set by the instrument design and does not always uniformly sample the LSF ( 30 , Fig. 10) . A final approach when neither of those options are available is to directly measure the width of observed lines by fitting either a Gaussian or Gauss-Hermite series. This does not allow for detailed profiles of the LSF to be determined, but it does allow sufficient generality for non-Gaussian features to

Read the complete text