Self-Supervised Calibration of Scientific Instruments Using Physical Consistency Constraints
M. Rejmund, A. Lemasson · 2026
Read Self-Supervised Calibration of Scientific Instruments Using Physical Consistency Constraints by M. Rejmund, A. Lemasson (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-29466.txt.
Introduction
Rejmund and Lemasson present a way for lab tools to calibrate themselves, without expert tuning or labelled data. Calibration, the step that aligns a tool's readings with known values, usually needs set procedures and hand labels. Their method is self-supervised and guided by physics. It learns hidden calibration values and task predictions together from raw readings. Known physical rules create pseudo-labels, rough stand-in labels, in repeated rounds.
They test the method on the VAMOS++ spectrometer, which sorts ions by charge. The model learns the settings of a segmented ion chamber while inferring ionic charge states at the same time. Starting from a weak guess about the mean charge, the rounds steadily sharpen the predictions. The learned values also track gain drift, pressure changes, and detector aging. The authors frame this as a step toward tools that can monitor and correct themselves during use.
Catalog record
| CREATOR | M. Rejmund, A. Lemasson |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 46 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.29466
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Self-Supervised Calibration of Scientific Instruments Using Physical Consistency Constraints M. Rejmund, A. Lemasson Abstract Calibration remains one of the principal obstacles to the deployment of machine learning in scientific instrumentation because it typically relies on expert intervention, dedicated procedures, and manually labelled data. We introduce a physics-informed self-supervised framework that jointly learns latent detector calibration parameters and task-specific predictions directly from raw measurements without requiring pre-calibrated signals or external labels. The method exploits known physical constraints to generate pseudo-labels iteratively, transforming calibration into a self-supervised optimization problem. The approach is demonstrated for ionic charge-state determination in the VAMOS++ magnetic spectrometer, where the calibration of a segmented ionization chamber and the inference of ionic charge states are learned simultaneously. Starting from a weak prior on the mean ionic charge state, the model progressively refines its predictions through iterative fractional pseudo-labelling driven by the discrete nature of atomic masses. Beyond accurate ionic charge-state reconstruction, the inferred calibration coefficients provide a compact representation of the detector state that enables automated monitoring of gain drifts, pressure variations, and detector aging. The resulting labels can subsequently be transferred to specialized models that quantify detector imperfections and track their spatial and temporal evolution. These results establish a general paradigm for self-calibrating and self-monitoring scientific instruments and represent a step toward intelligent experimental systems capable of autonomous calibration, analysis, and performance optimization. [orcid = 0009-0009-8626-8756] [orcid =0000-0002-9434-8520] keywords self-supervised learning ,latent calibration ,physics-informed machine learning ,scientific machine learning ,intelligent instrumentation , 1 Introduction Modern scientific instruments generate increasingly large volumes of complex, high-dimensional data. From particle detectors and astronomical observatories to medical imaging devices and industrial sensor networks, extracting reliable information from these measurements relies critically on accurate detector calibration. Calibration procedures establish the relationship between raw detector signals and physically meaningful quantities, enabling quantitative interpretation of experimental observations. Despite recent advances in machine learning, calibration remains one of the principal obstacles to the deployment of artificial intelligence in scientific instrumentation. Conventional calibration procedures are typically expert-driven, experiment-specific, and require dedicated measurements, iterative corrections, and extensive human intervention. In many applications, the generation of labelled training data itself depends on approximate calibration procedures, creating a circular dependency between calibration and inference. As a consequence, supervised learning approaches often suffer from limited scalability, reduced reproducibility, and poor adaptability to evolving experimental conditions. These limitations have motivated increasing interest in self-supervised and physics-informed machine learning approaches, where prior knowledge is incorporated directly into the learning process. In scientific domains, physical laws, conservation principles, and consistency constraints can provide powerful sources of supervision, reducing or eliminating the need for manually labelled data. Rather than treating calibration as a prerequisite for data analysis, an alternative paradigm is to formulate calibration itself as a learning problem constrained by known physical relationships. Such an approach enables a broader transition from static calibration procedures toward intelligent instrumentation. In this emerging paradigm, detector systems continuously infer their own calibration state from incoming data, monitor their performance over time, identify deviations from optimal operating conditions, and provide information for corrective actions. Calibration parameters are no longer viewed merely as intermediate quantities required for data analysis but become detector-state observables that characterize the health and performance of the instrument. In this work, we introduce a physics-informed self-supervised framework that jointly learns detector calibration parameters and task-specific predictions directly from raw measurements without requiring pre-calibrated signals or externally provided labels. The approach combines weak physical priors, iterative fractional pseudo-labelling, and domain-specific consistency constraints to progressively refine both the detector calibration and the inferred quantities of interest. We demonstrate the proposed framework using the VAMOS++ large-acceptance magnetic spectrometer ( 13 , 19 ) at Grand Accélérateur National d’Ions Lourds as a challenging case study. VAMOS++ is widely used in nuclear physics experiments for the identification of reaction products produced in heavy-ion collisions. Accurate reconstruction of the ionic charge state is essential for determining the atomic mass of detected ions. However, ionic charge-state identification depends critically on the calibration of a segmented ionization chamber, whose response may vary with detector gain, gas pressure, operating conditions, and local detector imperfections. Previous machine-learning approaches applied to VAMOS++ have demonstrated substantial improvements in ion trajectory reconstruction and particle identification. Nevertheless, these methods relied on approximate online calibrations to generate partially labelled datasets. The requirement for labelled data remains a major limitation for the broader deployment of AI-based analysis pipelines. The present work addresses this challenge by eliminating the dependence on pre-calibrated detector signals. Instead, detector calibration coefficients and ionic charge-state assignments are jointly inferred from raw detector observables using only weak physical priors and physically motivated consistency constraints. Specifically, the discrete nature of atomic masses is exploited to generate pseudo-labels iteratively, transforming detector calibration into a self-supervised optimization problem. Beyond enabling automatic label generation, the inferred calibration coefficients provide a compact representation of the detector state and can therefore be monitored as a function of time, operating conditions, or detector coordinates. Variations in these coefficients may reveal gain drifts, pressure fluctuations, aging effects, or other changes in detector response. Furthermore, the automatically generated labels can be transferred to specialized models designed to account for detector non-uniformities and higher-order effects, enabling the spatial and temporal characterization of detector imperfections. The present work makes four primary contributions: 1. We formulate detector calibration as a physics-informed self-supervised learning problem. 2. We introduce an iterative fractional pseudo-labelling framework that jointly estimates latent calibration parameters and task-specific predictions directly from raw measurements. 3. We demonstrate that physical consistency constraints can be used to infer calibration parameters directly from raw measurements. 4. We establish a pathway toward intelligent instrumentation by integrating calibration, analysis, and detector diagnostics within a unified framework. Although demonstrated on a nuclear-physics detector, the proposed framework is applicable to a broad range of scientific instruments for which calibration parameters are latent variables and physical consistency constraints are available. Examples include particle detectors, astronomical instrumentation, medical imaging systems, fusion diagnostics, and industrial sensor networks. The proposed framework shares conceptual similarities with expectation-maximization algorithms, self-training methods, and physics-informed machine learning, while addressing the unique challenge of learning latent calibration parameters directly from raw detector measurements. These results establish a pathway toward self-calibrating and self-monitoring scientific instruments in which calibration, data analysis, and performance evaluation are integrated within a unified adaptive framework. 2 Related Work The increasing complexity and data throughput of modern scientific instruments have stimulated growing interest in artificial intelligence methods for calibration, and data analysis. However, most existing approaches assume that detector calibration has already been performed and that labelled datasets are available for training. 2.1 Machine Learning for Scientific Instrumentation Supervised learning methods have demonstrated remarkable performance for tasks such as event classification, particle identification, trajectory reconstruction, detector calibration, anomaly detection, and experimental control. In nuclear and particle physics, deep neural networks have been applied successfully to detector reconstruction pipelines, significantly improving processing speed and analysis reproducibility ( 14 , 10 , 3 , 1 ). Nevertheless, the deployment of supervised learning in scientific instrumentation remains limited by the cost and availability of labelled data. In many cases, labels are obtained through dedicated calibration procedures, simulations, or expert-driven analyses. Consequently, the generation of training datasets often depends on the very calibration procedures that machine learning