Read All-directional gamma-ray imaging using a ๐๐š๐ˆ โก ( ๐“๐ฅ ) \mathrm{NaI(Tl)} scintillator with double-sided SiPM readout by Anzori Sh. Georgadze (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-29411.txt.

Introduction

Georgadze presents a compact detector that can tell which direction gamma rays, a very energetic form of light, come from. Instead of heavy collimators, meaning metal parts that block most rays, or complex Compton cameras, the design uses one sodium iodide crystal. Silicon photomultipliers, small light sensors, sit on both faces of that crystal. Light patterns from the two faces reveal where each ray struck inside.

Simulations with the GEANT4 toolkit tested rays from a caesium source. Georgadze reports an energy resolution near seven percent and sharp direction estimates. One method, called active masking, uses the crystal itself to block low energy rays. Another uses Compton scattering, where a ray bounces inside the crystal, for higher energies. Background radiation from below fell by a factor of about 320 in two minutes. The design also meets a standard for handheld radionuclide identification devices, which name radioactive materials.

Catalog record

CREATORAnzori Sh. Georgadze
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35 KB
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2606.29411

Browse the full library ยท About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

All-directional gamma-ray imaging using a ๐๐š๐ˆ โก ( ๐“๐ฅ ) \mathrm{NaI(Tl)} scintillator with double-sided SiPM readout Anzori Sh. Georgadze Abstract Gamma-ray imaging systems capable of determining the direction of incident radiation are essential for homeland security, nuclear non-proliferation, environmental monitoring, and radiological emergency response. Conventional directional detectors typically rely on heavy mechanical collimators, coded apertures, or complex multi-layer Compton cameras, resulting in significant trade-offs between detection efficiency, system weight, and complexity. This work presents a compact, high-efficiency omnidirectional gamma-ray imaging concept based on a monolithic cylindrical 2 ร— 2 2\times 2 inch NaI(Tl) scintillation crystal coupled to dual-ended 16 ร— 16 16\times 16 Silicon Photomultiplier (SiPM) matrices. The system exploits scintillation light distributions collected from both crystal faces to reconstruct three-dimensional interaction positions and depth-of-interaction (DOI). Detailed GEANT4 Monte Carlo simulations ( 4.0 ร— 10 8 4.0\times 10^{8} primary histories) incorporating full optical photon transport were performed for 662 keV gamma rays from a 137 Cs source. The simulated energy resolution is 6.69 % ยฑ 0.31 % 6.69\%\pm 0.31\% FWHM at the photopeak. A hybrid directional reconstruction framework is implemented, combining volumetric self-attenuation (active masking) for robust low-energy localization with intra-crystal Compton imaging for higher energies. With approximately 40,000 accumulated photopeak counts, the active-masking algorithm achieves angular resolutions of FWHM elev โ‰ˆ 5.7 โˆ˜ {}_{\rm elev}\approx 5.7^{\circ} and FWHM az โ‰ˆ 3.7 โˆ˜ {}_{\rm az}\approx 3.7^{\circ} . The system fully complies with the EN IEC 62327 standard for handheld radionuclide identification devices. Under the required 120-second acquisition window, it suppresses terrestrial background (NORM) from the lower hemisphere by a factor of โ‰ˆ \approx 320, improving to โ‰ˆ \approx 980 with 300-second integration. These results demonstrate that a monolithic dual-ended NaI(Tl) detector can transform a conventional scalar spectrometer into a sensitive, real-time directional imaging instrument suitable for portable field use and automated cargo inspection. 1 Introduction Gamma-ray imaging systems capable of determining the direction of incident radiation are essential in numerous fields, including homeland security, nuclear safeguards, environmental monitoring, astrophysics, and medical imaging [ 1 , 2 ] . Unlike conventional detectors that provide only count rate or spectroscopic information, directional systems enable source localization and radiation-field mapping in complex environments [ 3 , 4 ] . Current gamma-ray imaging technologies rely primarily on mechanical collimation, coded apertures, or Compton scattering reconstruction [ 5 , 6 ] . Each approach involves fundamental trade-offs between angular resolution, detection efficiency, field of view, and system complexity. Mechanically collimated and coded-aperture systems typically suffer from low efficiency or heavy shielding requirements, while conventional Compton cameras often require multi-layer segmented detectors, leading to increased complexity, dead space, and parallax effects [ 7 , 8 ] . Hybrid approaches combining active masking with Compton imaging have recently gained attention as a means to overcome these limitations [ 9 , 10 ] . Active masking exploits self-attenuation within the detector volume to provide directional sensitivity at lower energies, while Compton kinematics extends performance at higher energies. This dual-mode strategy offers the potential for wide dynamic range within a single compact detector. In this work, we investigate an omnidirectional gamma-ray imaging concept based on a monolithic cylindrical NaI(Tl) scintillator with dual-ended Silicon Photomultiplier (SiPM) matrix readout. The cylindrical geometry provides near- 4\pi coverage while maintaining mechanical simplicity. Simultaneous readout from opposing crystal faces enables reconstruction of both transverse position and depth-of-interaction (DOI) through analysis of scintillation light distributions. The detector performance is evaluated using detailed GEANT4 Monte Carlo simulations incorporating full optical photon transport. A 2^{\prime\prime}\times 2^{\prime\prime} NaI(Tl) crystal coupled to 16\times 16 SiPM arrays on both ends is modeled and irradiated with 662 keV gamma rays from a 137 Cs source. Particular attention is given to compliance with the international standard EN IEC 62327 for handheld radionuclide identification devices. This paper presents the detector concept, simulation methodology, reconstruction algorithms (active masking and Compton back-projection), and quantitative directional performance results. The proposed architecture demonstrates the feasibility of compact, high-efficiency directional gamma-ray detection without mechanical collimation. 2 Materials and methods 2.1 GEANT4 modeling of a NaI(Tl) scintillation detector The detector consists of a monolithic cylindrical NaI(Tl) crystal with dimensions \varnothing 2 inch \times 2 inch ( 50.8\,\mathrm{mm}\times 50.8\,\mathrm{mm} ) as shown in figure 1 . The crystal is housed in a light-tight aluminum enclosure internally coated with MgO powder (reflectivity \approx 97\% ). Both end faces are sealed with borosilicate glass windows, and 16\times 16 SiPM arrays are optically coupled to each window using optical grease. This configuration yields 256 channels per face and 512 channels in total. Figure 1 : (a) Schematic of the dual-ended readout NaI(Tl) detector showing the coordinate system and SiPM array placement. (b) Example GEANT4 visualization of a 662 keV 137 Cs interaction. Light green lines represent optical photon trajectories propagating toward the top and bottom SiPM arrays. The resulting light distribution on each array encodes the three-dimensional position of the interaction. The detector response was modeled using the GEANT4 Monte Carlo simulation toolkit [ 11 ] , incorporating full electromagnetic, optical photon transport, and boundary physics. The simulated geometry consists of a 2\times 2 inch cylindrical NaI(Tl) crystal enclosed in an aluminum housing. The top and bottom faces are coupled to borosilicate glass windows, while the lateral surfaces are lined with MgO reflective material. Key optical parameters for NaI(Tl) at the emission peak ( \lambda=415 nm) include: density 3.67 g/cmยณ, scintillation yield 38{,}000 photons/MeV, decay time 230 ns, and refractive index n=1.85 , bulk absorption length 50 cm. Optical photons are transported using the G4OpticalPhysics module with the GLISUR model for boundary processes [ 12 , 13 ] . The MgO reflector is modeled as a diffuse (groundbackpainted) surface with reflectivity 0.98, and the aluminum housing as a polished surface with reflectivity 0.88. Optical coupling between the crystal, glass window, and SiPM is realized via a thin layer of optical grease ( n=1.47 ). A Hamamatsu S13360-series SiPM was used as a reference photodetector. The effective photon detection efficiency (PDE), weighted by the NaI(Tl) emission spectrum, was set to approximately 40%. Electromagnetic interactions were simulated using the G4EmLivermorePhysics list. A total of 4.0\times 10^{8} primary 137 Cs gamma-ray histories were generated to accumulate sufficient statistics in the photopeak and Compton continuum. For each event, the integrated charge in all 512 SiPM channels (256 top + 256 bottom) was recorded and served as input to the subsequent energy- and position-reconstruction algorithms. 3 Gamma source direction determination 3.1 Compton imaging via intra-crystal two-interaction reconstruction A key innovation of the proposed architecture is its ability to perform Compton imaging entirely within a single monolithic NaI(Tl) crystal. This is accomplished by identifying and reconstructing two-interaction sequences โ€” a primary Compton scatter followed by photoelectric absorption โ€” using high-granularity SiPM readout. For a valid Compton event, the two interaction sites produce distinct scintillation light pools. These overlapping distributions are decomposed using a two-component Gaussian-mixture model (or non-linear least-squares fit of light response functions) applied to the summed top+bottom SiPM response (Figure 2 ). Figure 2 : Example of a multi-interaction event in the monolithic scintillator. (a) 3D light distribution. (b) 2D projection on the SiPM plane. A two-component Gaussian mixture model is used to resolve the positions and relative energies of the two interaction sites. The Compton scattering

Read the complete text