Read Distributed Air-Gap Flux and Rotor-Current Fusion for Operating-Regime Identification in a 10-MW Kaplan Hydrogenerator by Eduardo Jr Piedad, Rafel Roig, Xavier Escaler, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-27800.txt.

Introduction

Monitoring a hydroelectric generator means reading both its load and its magnetic field. Eduardo Piedad and four colleagues study the Porjus U9 generator in 2026. It is a ten-megawatt Kaplan unit. Synchronised measurements came from ten stator-mounted Hall probes and six rotor-current channels. Seven steady guide-vane settings were recorded. Each record was sliced into one-second windows.

Features describe the air-gap field's spatial pattern and each probe's time behaviour. Three classifiers were tested on identifying the guide-vane state. Spatial flux features alone separated the states poorly, with test accuracy below twenty-seven percent. Rotor-current features alone reached about eighty-four to eighty-five percent. Combining both sources worked far better. A support-vector classifier with a radial basis kernel reached ninety-nine point five percent test accuracy. Current features track the loading axis, while flux features add imbalance and distortion information.

Catalog record

CREATOREduardo Jr Piedad, Rafel Roig, Xavier Escaler, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE26 KB
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2606.27800

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Distributed Air-Gap Flux and Rotor-Current Fusion for Operating-Regime Identification in a 10-MW Kaplan Hydrogenerator Eduardo Jr Piedad, Rafel Roig, Xavier Escaler, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt Abstract Reliable monitoring of hydroelectric generators requires descriptors that capture both electrical loading and electromagnetic field behavior. This work investigates operating-regime identification in the Porjus U9 10-MW Kaplan hydrogenerator using synchronized measurements from ten stator-mounted Hall probes and six rotor-current channels. Seven steady guide-vane-opening settings are considered, and each 300 s record is divided into 1 s windows. The resulting windows are represented by spatial Fourier descriptors of the circumferential air-gap field, probe-wise temporal flux indicators, and channel-wise RMS rotor-current features. Correlation analysis and principal component analysis are used to examine how the feature groups vary with the operating point, and Random Forest, radial-basis-function support vector classification, and multilayer perceptron models are evaluated for supervised identification of the guide-vane-opening state. The analysis shows that RMS rotor-current features mainly track the loading axis, while the magnetic-flux features reveal complementary information associated with spatial imbalance, waveform distortion, and weak low-frequency modulation. Spatial descriptors alone provide limited separability, yielding test accuracies below 27%, whereas rotor-current features alone reach about 84–85%. Combining flux and current information gives the most discriminative representation; the SVC-RBF model achieves 99.5% test accuracy and macro-F1 score. The results indicate that distributed air-gap magnetic sensing, when fused with rotor-current measurements, can support accurate and interpretable data-driven monitoring of Kaplan hydrogenerator operating regimes. K eywords Air-gap flux \cdot hydrogenerator monitoring \cdot operating-regime identification \cdot rotor current \cdot machine learning 1 Introduction Hydropower is a key source of dispatchable renewable energy, and its role is increasingly important as power systems accommodate greater variability from renewable generation. This requires hydroelectric units to operate over wider hydraulic and electrical ranges, increasing the need for reliable condition monitoring under changing operating conditions. In Kaplan turbine-generator units, variations in guide vane opening (GVO) affect generator loading and may influence air-gap flux distortion, modulation, and spatial non-uniformity. These effects motivate signal-processing and machine-learning methods that can characterize operating states from measured generator signals. Data-driven condition monitoring has been widely applied to hydropower and rotating machinery for anomaly detection, predictive maintenance, and operating-regime identification [ 3 , 6 , 1 , 7 ] . Although deep learning has received significant attention, recent work has shown that simpler machine-learning methods can outperform deep models in motor fault detection when informative signal features are available [ 4 ] . This supports the use of physically interpretable feature extraction combined with supervised classifiers, especially when transparency and compact representations are important. For hydrogenerators, rotor-current measurements provide useful loading information but do not fully describe the spatial distribution of the air-gap magnetic field. Distributed magnetic sensing offers a more direct view of electromagnetic asymmetry, rotor eccentricity, field distortion, and air-gap non-uniformity. Previous studies have demonstrated the diagnostic relevance of air-gap flux measurements in hydrogenerators and synchronous generators [ 2 , 8 ] . However, the combined use of spatially distributed flux probes and rotor-current features for operating-state classification remains less explored. This paper presents a spatiotemporal analysis and data-driven classification framework for a 10-MW Kaplan turbine generator using synchronized air-gap flux-density and rotor-current measurements. Ten stator-mounted Hall probes characterize the spatial and temporal behavior of the air-gap field, while six rotor-current channels provide loading-related information. From 1 s steady-state windows, spatial Fourier indicators, probe-resolved temporal flux features, and channel-wise RMS current features are extracted. Correlation analysis and PCA are used for interpretation, while supervised classifiers are used to evaluate GVO separability. The objective of this work is to assess how spatial flux structure, temporal flux distortion, and rotor-current loading information contribute to the classification of Kaplan turbine generator operating conditions. The results show that current features primarily represent electrical loading, while flux-based features provide complementary spatial and modulation information. Their combination provides an effective representation for data-driven GVO classification and supports the use of distributed magnetic sensing for hydrogenerator condition monitoring. 2 The 10-MW Generator This study uses measurements from the actual Porjus U9 Kaplan turbine generator. The generator configuration defines the spatial arrangement of the flux measurements, while the operating regimes provide labeled steady-state conditions for data-driven analysis. 2.1 Generator Configuration The Porjus U9 unit is a three-phase synchronous generator. Its main parameters are summarized in Table 1 . The machine has 10 poles and operates at a reference speed of 600 rpm, corresponding to a 50 Hz electrical frequency. The stator has 120 slots, an outer diameter of 3050 mm, an inner diameter of 2000 mm, and an axial length of 1450 mm. These parameters define the electromagnetic periodicity of the machine and provide the spatial reference for interpreting air-gap flux measurements around the stator. Spatial magnetic measurements are particularly relevant for this generator because air-gap flux density is sensitive to non-uniform magnetic conditions around the machine circumference. Prior electromagnetic simulations under eccentric operation [ 5 ] indicate that voltage and flux-linkage waveforms are only weakly affected, whereas air-gap flux density, stator tooth forces, and torque show more evident asymmetry. This motivates the use of distributed flux measurements, together with rotor-current sensing, for monitoring operating-state behavior. Table 1: Key parameters of the Porjus U9 synchronous generator. Parameter Value Unit Machine type Three-phase synchronous – Number of poles 10 – Reference speed 600 rpm Electrical frequency 50 Hz Stator outer diameter 3050 mm Stator inner diameter 2000 mm Stator axial length 1450 mm Number of stator slots 120 – Stacking factor 0.97 – Stator steel type U9_stator – 2.2 Flux and Current Measurements The dataset consists of synchronized air-gap flux-density and rotor-current signals acquired under steady-state operation. Flux density was measured using ten stator-mounted Hall-effect probes uniformly distributed around the stator, giving an angular spacing of 36^{\circ} ; hence, the probe locations are defined as \theta_{k}=36^{\circ}(k-1) , for k=1,\dots,10 . Six rotor-current channels were recorded simultaneously to capture the corresponding excitation-current behavior. All channels were sampled at 250 Hz for seven guide vane opening (GVO) conditions, \{14^{\circ},16^{\circ},18^{\circ},20^{\circ},22^{\circ},24^{\circ},26^{\circ}\} . Each operating condition contains a 300 s steady-state record. For subsequent analysis, each record is segmented into non-overlapping 1 s windows, corresponding to T=250 samples per window. The flux signal from Hall probe k is denoted by B_{k}(t) , and the rotor-current signal from channel j is denoted by i_{j}(t) . 3 Methodology A signal-processing and learning framework shown in Fig. 1 is used to convert the synchronized flux-density and rotor-current measurements into features for GVO classification. Each 1 s window is processed through parallel flux and current branches. Flux signals are used to extract spatial and temporal indicators, while rotor-current signals are converted into channel-wise RMS features. The resulting features are analyzed using correlation analysis and PCA, and are then evaluated using supervised classifiers. Measurements B_{k}(t),\,i_{j}(t),\,\mathrm{GVO} 1 s windowing Flux and current branches Spatial FFT B_{1} , SNI Welch PSD A_{1,k} , FTDI, FMI RMS current I_{\mathrm{RMS},j} Feature combinations Correlation PCA RF, SVC, MLP Figure 1: The spatiotemporal analysis and classification framework. 3.1 Window-Level Representation Each 300 s steady-state record is divided into non-overlapping 1 s windows. Let w denote a window containing T=250 samples. The windowed flux-density and rotor-current signals are denoted by \displaystyle B_{k}^{(w)}(t),\quad k=1,\dots,10, (1) \displaystyle i_{j}^{(w)}(t),\quad j=1,\dots,6,\quad t=1,\dots,T. Each window inherits the GVO

Read the complete text