A Sensorised Lattice Footplate for a Semi-Active Prosthetic Foot
Jinze Ge, Jingcheng Sun, Chengxu Zhou · 2026
Read A Sensorised Lattice Footplate for a Semi-Active Prosthetic Foot by Jinze Ge, Jingcheng Sun, Chengxu Zhou (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-25966.txt.
Introduction
Jinze Ge, Jingcheng Sun, and Chengxu Zhou ask whether the sole of a prosthetic foot can feel as well as carry weight. Their prototype hides magnetic pressure sensors inside a 3D-printed lattice footplate, the springy load-bearing part of a semi-active prosthetic foot built at low cost. A servo-driven hydraulic damper, whose settings map to measured damping levels, adds adjustable resistance at the ankle.
Compression tests confirm the lattice stiffness can be tuned as designed. Under repeated loading, the buried sensor tracks the test machine's reference force closely, showing ground pressure can be estimated without a separate insole. Standing trials at roughly body weight separate front-foot and rear-foot loading cleanly across four set postures. A feedforward damping schedule follows a reference ankle motion through early and mid stance, though a purely damping device cannot supply push-off power.
Catalog record
| CREATOR | Jinze Ge, Jingcheng Sun, Chengxu Zhou |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 28 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.25966
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Sensorised Lattice Footplate for a Semi-Active Prosthetic Foot Jinze Ge, Jingcheng Sun, Chengxu Zhou Abstract This paper investigates whether magnetic plantar sensing can be embedded directly inside the load-bearing compliant element of a low-cost semi-active prosthetic foot. We present a prototype integrating a sensorised 3D-printed lattice footplate, a servo-adjustable hydraulic damper, and a reduced-order ankle model. The damper is experimentally characterised to relate adjustment angle to damping coefficient. Controlled compression tests show tunable lattice stiffness, while cyclic normal loading shows that the embedded sensor tracks the testing-machine reference force, supporting plantar-force estimation without an external insole layer. Static-posture trials under approximately body-weight loading show that forefoot and rearfoot loading distributions are separable across four prescribed stance configurations, providing a preliminary check of the sensing pipeline. A feedforward damping schedule approximates the dorsiflexion trend of a reference ankle trajectory through early-to-mid stance, while exposing the expected limitation that a purely dissipative mechanism cannot generate active push-off. Together, these results demonstrate that sensing can be embedded inside the load-bearing compliant element of a prosthetic foot and used to drive semi-active damping. I Introduction Lower-limb prosthetic feet are required to provide stable load support, impact attenuation, rollover assistance, and energy return during walking. The need for practical and affordable prosthetic solutions is increasing, as approximately 50,000 people currently live with lower-limb loss in the United Kingdom [ 9 ] , while the number of individuals with major lower-limb loss in the United States is projected to increase substantially by 2050 [ 19 ] . Among existing prosthetic foot technologies, passive energy-storing-and-returning (ESR) feet remain widely used because of their robustness, low mass, and relatively low cost [ 17 , 7 ] . However, their stiffness and damping characteristics are largely fixed after manufacture and alignment, which limits their ability to adapt to gait phase, walking speed, terrain, and user loading conditions. This can lead to reduced terrain adaptability, limited push-off assistance, compensatory gait strategies, and increased loading on the intact limb [ 15 , 1 ] . In addition, the reliance on carbon-fibre composite structures may increase manufacturing cost and raise sustainability concerns [ 11 ] . Fig. 1: Overview of the proposed semi-active prosthetic foot. (a) CAD assembly showing the articulated ankle mechanism, hydraulic damper, and 3D-printed elastic footplate. (b) Servo-driven damping adjustment module. (c) Gear transmission used to amplify servo rotation for damper adjustment. The human ankle–foot complex provides phase-dependent mechanical behaviour during walking, including controlled plantar flexion, controlled dorsiflexion, and powered plantar flexion [ 17 , 1 ] . A key feature of the biological ankle is its ability to modulate quasi-stiffness according to walking speed, body mass, and terrain. Powered ankle–foot prostheses have therefore been developed to reproduce biological ankle torque and power more closely, particularly during late stance push-off [ 1 , 10 ] . Nevertheless, the motors, transmissions, batteries, sensors, and embedded control systems required for active power delivery increase device mass, cost, and structural complexity, which may reduce socket comfort and daily clinical practicality [ 8 ] . Quasi-passive and semi-active prostheses provide an alternative approach by regulating stiffness, damping, or joint configuration without continuously injecting net positive work. Variable-stiffness and semi-active designs have demonstrated improved ankle motion, energy storage and return, slope adaptation, and reduced contralateral loading in different walking conditions [ 6 , 16 , 4 ] . However, many of these systems still rely on specialised mechanisms, costly materials, or limited sensing integration [ 16 , 4 ] . Beyond ankle-level impedance control, prosthetic foot performance is also strongly affected by the compliance of the footplate and sole. Biomimetic and additively manufactured designs can improve distributed compliance, reduce material usage, and enable patient-specific geometry [ 12 , 5 ] . However, most of these structures remain passive and provide limited gait-dependent damping modulation. Adaptive prosthetic control also requires reliable information about foot–ground interaction. Plantar sensing can support gait-event detection, load estimation, and damping regulation [ 13 ] . However, insole-based sensing remains external to the main load-bearing structure. Recent magnetic tactile sensing approaches show that deformation-induced magnetic-field changes within compliant structures can be used for contact localisation and force estimation [ 14 ] . Embedding this sensing principle directly into a load-bearing prosthetic lattice could hence provide compact plantar force estimation while avoiding a separate external sensing layer. This paper investigates whether magnetic plantar sensing can be embedded directly into the load-bearing compliant element of a low-cost prosthetic foot, and whether the resulting force readout is informative enough to support a preliminary semi-active damping strategy under controlled prototype conditions. To answer these questions, we design and characterise an integrated prototype, shown in Fig. 1 , that combines a sensorised 3D-printed lattice footplate, a servo-adjustable hydraulic damper, and a reduced-order linkage model of the articulated ankle. The main contributions are: • A sensorised lattice footplate that integrates magnetic plantar sensing inside the load-bearing compliant element, eliminating a separate insole sensing layer. • A reduced-order articulated-ankle model coupled with experimental damper characterisation, providing a simulation framework for the proposed mechanism. • Mechanical, sensing, and prototype-level characterisation, including a stance-phase simulation against a literature reference and a static-posture preliminary check of the end-to-end sensing pipeline. The remainder of this paper is organised as follows. Section II describes the system design and modelling framework. Section III presents the experimental validation, simulation results, and discussion. Section IV concludes the paper and outlines future work. II System Design and Modelling II-A Mechanical Architecture of the Proposed Design The proposed prosthesis combines an articulated load-bearing frame, an adjustable hydraulic damper, and a 3D-printed elastic footplate, as shown in Fig. 1 (a). A standard pyramid adapter connects the device to the prosthetic socket and transfers body weight to the main frame. The upper, ankle, and front hinges constrain motion mainly to the sagittal plane, enabling controlled ankle rotation during stance while maintaining structural support for body-weight transmission. A hydraulic damper is mounted obliquely between the upper frame and the anterior distal linkage. In the intended stance-phase operation, ankle rotation changes the damper length through the linkage, generating a velocity-dependent resisting force that can regulate the angular response of the ankle. To enable adjustable damping for semi-active modulation, the damper is coupled to a servo-driven gear transmission. As illustrated in Fig. 1 (b) and (c), approximately 120^{\circ} of servo rotation is converted into approximately 270^{\circ} of damper adjustment, increasing the available damping range while keeping the actuation module compact. The distal footplate is fabricated as a compliant 3D-printed lattice rather than a conventional monolithic carbon-fibre spring. This structure provides distributed deformation under plantar loading, contributing to shock attenuation, load redistribution, and controlled rollover during stance. The lattice geometry also allows the footplate stiffness to be tuned through unit-cell size and material selection. In the overall design, the articulated damper modulates joint-level resistance, whereas the elastic lattice footplate provides localised foot–ground compliance. By combining these functions, the proposed architecture integrates load-bearing support, adjustable ankle damping, and compliant plantar interaction within a compact semi-active prosthetic-foot platform. II-B Plantar Sensing Module Fig. 2: Embedded plantar sensing module. (a) Assembly of the lattice sensing body, embedded magnets, and magnetometer PCB. (b) Design and fabrication workflow showing lattice generation, magnet-layer integration, and the PEBA 3D-printed sensing