Finite-Shot Sensitivity for Moment Estimation in Quantum Metrology
Shaowei Du, Shuheng Liu, Weidong Li, Luca Pezzè, Augusto Smerzi, Qiongyi He · 2026
Read Finite-Shot Sensitivity for Moment Estimation in Quantum Metrology by Shaowei Du, Shuheng Liu, Weidong Li, Luca Pezzè, Augusto Smerzi, Qiongyi He (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-25920.txt.
Introduction
Shaowei Du and colleagues work in quantum metrology, the science of measuring physical quantities with quantum sensors. The famous quantum Cramér-Rao bound states the best precision possible, but only in the limit of endlessly many measurements. It says nothing about how many measurements a real estimator needs. Real work happens far from that ideal limit.
Method-of-moments estimation, which infers a parameter from the average of one measured quantity, is the setting Du's team analyzes for finite measurement counts. Curved calibration responses bias the simple estimator. The team builds a corrected version whose bias shrinks much faster. Their formulas give the corrections beyond the usual leading term. They also give a condition under which the first correction vanishes entirely. Concrete thresholds show when the textbook limiting sensitivity becomes visible in practice.
Catalog record
| CREATOR | Shaowei Du, Shuheng Liu, Weidong Li, Luca Pezzè, Augusto Smerzi, Qiongyi He |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 50 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.25920
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Finite-Shot Sensitivity for Moment Estimation in Quantum Metrology Shaowei Du, Shuheng Liu, Weidong Li, Luca Pezzè, Augusto Smerzi, Qiongyi He Abstract The quantum Cramér–Rao bound can be saturated only asymptotically and does not specify how many measurements are needed for a concrete estimator to approach it. We develop a finite-measurement theory for method-of-moments estimation, where the parameter is inferred from the sample mean of a calibrating observable rather than from the full likelihood. For general quantum statistical models, the expansion is written in terms of the calibration curve and the central moments of the measured observable. Nonlinear calibration curves make the usual moment estimator biased at finite measurement number; we construct a bias-corrected estimator with bias O ( ν − 3 ) O(\nu^{-3}) . This gives sensitivity corrections beyond the leading error-propagation term of the chosen moment protocol. We identify a general density-matrix condition under which the full 1 / ν 2 1/\nu^{2} correction vanishes. In unitary examples, the leading residual correction appears at order 1 / ν 3 1/\nu^{3} , is governed by calibration curvature, and can be reduced or cancelled by higher-rank components of the same measured observable. The resulting thresholds quantify how many measurements are needed before the asymptotic sensitivity of a moment-estimation protocol is operationally visible. Introduction— Precision measurements play a central role in modern physics Ye and Zoller 2024 , with applications ranging from gravitational-wave detection Aasi et al. 2013 ; Tse et al. 2019 and atomic clocks Pedrozo-Peñafiel et al. 2020 ; Ye and Zoller 2024 to magnetometry Wasilewski et al. 2010 ; Wolfgramm et al. 2010 and bioimaging Taylor and Bowen 2016 ; Ahmed et al. 2026 . Quantum sensing and metrology provide the framework for exploiting quantum states and measurements to estimate physical parameters with sensitivities beyond classical limits Paris 2009 ; Giovannetti et al. 2011 ; Degen et al. 2017 ; Pezze et al. 2018 . The field is usually organized around asymptotic local benchmarks. For a quantum statistical model \rho_{\theta} , the quantum Cramér–Rao bound (QCRB) gives the best leading precision attainable by locally unbiased estimators after optimizing over measurements Helstrom 1969 ; Holevo 2011 ; Braunstein and Caves 1994 . This benchmark underlies quantum-enhanced sensing and the use of quantum Fisher information as a witness of metrologically useful multipartite entanglement and squeezing Pezzé and Smerzi 2009 ; Hyllus et al. 2012 ; Tóth 2012 , and continues to guide recent schemes based on nonlinear dynamics and optimized metrological protocols Imai et al. 2025 ; Du et al. 2022 ; Zhao et al. 2020 ; Kong et al. 2026 . A complementary question, which is central in practice, is how a concrete measurement-and-estimator scheme approaches the QCRB when only a finite number of measurements is available. Reaching the leading bound requires both suitable measurements and appropriate estimator conditions Pezzè and Smerzi 2014 ; Gessner and Smerzi 2023 . Although optimal measurements are known to exist for single-parameter estimation in ideal settings Liu et al. 2020 ; Kurdziałek and Demkowicz-Dobrzański 2023 ; Zhou et al. 2020 , their implementation may be limited by experimental imperfections such as measurement noise Datta et al. 2011 ; Len et al. 2022 ; Zhou et al. 2023 . Moreover, standard strategies including maximum-likelihood Polino et al. 2019 ; Hervas et al. 2025a ; Hervas et al. 2025b , method-of-moments Gessner et al. 2019 ; Gessner et al. 2020 , and Bayesian estimation Li et al. 2018 ; Rubio and Dunningham 2019 ; Han et al. 2024 generally approach their asymptotic benchmarks only in the large-sample limit. Classical statistics already provides stronger finite-sample benchmarks beyond the Cramér–Rao bound Barankin 1949 ; Abel 2002 ; Gebhart et al. 2024 , and quantum extensions have led to hierarchies of few-measurement bounds and to global-estimation approaches in both frequentist and Bayesian settings Gessner and Smerzi 2023 ; Shi and Smerzi 2026 ; Mukhopadhyay et al. 2025 . Recent higher-order likelihood theory, built on classical asymptotic statistics Rao 1965 ; Braunstein 1992 , has shown that measurements and states that are equivalent at the QCRB level can differ at finite sample size Hervas et al. 2025a ; Hervas et al. 2025b . Such likelihood-based methods, however, typically require calibration of the full outcome distribution as a function of the unknown parameter Pezzè and Smerzi 2014 . Many quantum-metrology experiments instead use only a few low-order moments of a measured signal, inferring the parameter from the sample mean of a calibrated observable without reconstructing the full likelihood Gessner et al. 2019 ; Gessner et al. 2020 ; Fadel et al. 2025 . Given such a moment estimator, how many repetitions are needed before the asymptotic sensitivity is operationally reached? The answer depends on finite-measurement corrections that are invisible at leading order. We formulate this finite-measurement problem directly at the level of measured moments. First, for arbitrary quantum statistical models \rho_{\theta} , we derive the bias-corrected method-of-moments expansion in terms of the calibration curve f(\theta)=\mathrm{Tr}[\rho_{\theta}M] and the central moments \mu_{n}(\theta)=\mathrm{Tr}[\rho_{\theta}(M-f(\theta)\mathbb{I})^{n}] . Second, we identify the general condition under which the 1/\nu^{2} correction to the bias-corrected mean-square error vanishes. Third, we illustrate the result in effective qubits, qudits with higher-rank measurement components, and continuous-variable models with linear calibration. The qudit case shows explicitly how measurement components that are invisible at leading order can reduce, and in suitable cases cancel, the leading residual 1/\nu^{3} correction. Moment estimation— We consider a real parameter encoded in a density matrix \rho_{\theta} . In the method of moments (MoM) estimation protocol, a Hermitian observable M is measured independently \nu times, producing outcomes M_{1},\ldots,M_{\nu} and sample mean \bar{M}=\frac{1}{\nu}\sum_{k=1}^{\nu}M_{k} . Provided the calibration curve f(\theta)=\mathrm{Tr}[\rho_{\theta}M] of nonzero first-order derivative, the usual MoM estimator is \hat{\theta}_{0}:=f^{-1}(\bar{M})\equiv g(\bar{M}). (1) We define the single-shot central moments \mu_{n}(\theta)=\mathrm{Tr}\!\left[\rho_{\theta}\bigl(M-f(\theta)\mathbb{I}\bigr)^{n}\right] . Expanding g(\bar{M}) around the calibrated mean \mathrm{Tr}[\rho_{\theta}M] gives the leading error-propagation formula of the mean square error (MSE) {\rm MSE}(\hat{\theta}_{0})=\frac{1}{\nu}\frac{\mu_{2}}{(f^{\prime})^{2}}+O(\nu^{-2}). (2) The above coefficient is the leading sensitivity achieved by measuring the chosen observable M . Throughout the paper, the primes are used to denote derivatives with respect to \theta . At finite \nu , this estimator is generally biased. Let \delta\bar{M}=\bar{M}-f(\theta) and expand the inverse calibration function around f(\theta) : g(f+\delta\bar{M})=\theta+\sum_{r\geq 1}\frac{g^{(r)}(f)}{r!}\,\delta\bar{M}^{r}. (3) Here g^{(r)} denotes the r -th derivative of g with respect to its argument, evaluated at f(\theta) . Using the mapping of central moments from single-shot to i.i.d. mean, we formulate the moments of the sample mean fluctuation, i.e. E[\delta\bar{M}^{n}] , into the powers of 1/\nu and obtains a series expansion of the bias of \hat{\theta}_{0} with respect to the true value \mathbb{E}_{\theta}[\hat{\theta}_{0}]-\theta=\frac{b_{1}(\theta)}{\nu}+\frac{b_{2}(\theta)}{\nu^{2}}+O(\nu^{-3}), (4) with b_{1}(\theta)=\frac{1}{2}g^{(2)}(f)\mu_{2}, and b_{2}(\theta)=\frac{1}{6}g^{(3)}(f)\mu_{3}+\frac{1}{8}g^{(4)}(f)\mu_{2}^{2}. See SM appendix S1 for details. As demonstrated in Eq. ( 4 ), the usual MoM estimator \hat{\theta}_{0} is asymptotically consistent, but a nonlinear calibration curve produces a finite-measurement bias. Consequently, the MSE of MoM estimator is corrected in this regime in the form of 1/\nu -series {\rm MSE}(\hat{\theta}_{0})=\frac{A}{\nu}+\frac{V_{0}}{\nu^{2}}+O(\nu^{-3}), (5) where we call A:={\mu_{2}}/{(f^{\prime})^{2}} , V_{0}:=-{\mu_{3}f^{\prime\prime}}/{(f^{\prime})^{4}}+{\mu_{2}^{2}}\left(15(f^{\prime\prime})^{2}/4-f^{\prime}f^{\prime\prime\prime}\right)/{(f^{\prime})^{6}} . As seen from Eq. ( 5 ), the finite- \nu bias does not change the leading 1/\nu sensitivity, but it should be removed to be locally unbiased for comparison with Cramér–Rao-type benchmarks beyond leading order. See SM appendix S1 for details. Bias-corrected estimation protocol— Consequently,