On-Sky Single-photon Time resolution of 35 ps with White Rabbit synchronization: towards the measurement of the size of a White Dwarf star

Federico Izraelevitch-Patitucci, Sarah Tolilla, Ilian Ellafi, Jean-Pierre Rivet, Mathilde Hugbart, Guillaume Labeyrie, Olivier Lai, Andreas Zmija, William Guerin, Robin Kaiser · 2026

Read On-Sky Single-photon Time resolution of 35 ps with White Rabbit synchronization: towards the measurement of the size of a White Dwarf star by Federico Izraelevitch-Patitucci, Sarah Tolilla, Ilian Ellafi, Jean-Pierre Rivet, Mathilde Hugbart, Guillaume Labeyrie, Olivier Lai, Andreas Zmija, William Guerin, Robin Kaiser (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-25817.txt.

Introduction

Sirius B, the white dwarf companion of the brightest star in the sky, packs a Sun's mass into an Earth sized body. Nobody has measured its diameter directly. Federico Izraelevitch-Patitucci and colleagues in the IC4Stars project aim to do it in 2026 with intensity interferometry. The method matches flickers in starlight between far apart telescopes. It demands single photon timing at tens of picoseconds, across instruments a kilometre apart. This report covers the project's latest milestones, from bench tests to sky.

In the laboratory the team tested their photon detectors, timing converters, and sync electronics. On sky, two converters locked together through the White Rabbit protocol over thirty metres of fibre. The achieved time resolution stayed below thirty five picoseconds. A new pipeline records raw time tags and computes the correlation function. Each milestone closes one gap toward resolving a white dwarf for the first time.

Catalog record

CREATORFederico Izraelevitch-Patitucci, Sarah Tolilla, Ilian Ellafi, Jean-Pierre Rivet, Mathilde Hugbart, Guillaume Labeyrie, Olivier Lai, Andreas Zmija, William Guerin, Robin Kaiser
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE21 KB
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2606.25817

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

On-Sky Single-photon Time resolution of 35 ps with White Rabbit synchronization: towards the measurement of the size of a White Dwarf star Federico Izraelevitch-Patitucci, Sarah Tolilla, Ilian Ellafi, Jean-Pierre Rivet, Mathilde Hugbart, Guillaume Labeyrie, Olivier Lai, Andreas Zmija, William Guerin, Robin Kaiser Abstract The IC4Stars (Intensity Correlation for Stars) project aims to measure the diameter of the white dwarf star Sirius B, using Intensity Interferometry. In this work we present our latest efforts and the milestones achieved in the last year. We report laboratory characterization of the single-photon detectors, TDC and synchronization electronics. We describe an observation campaign where we demonstrated on-sky time resolution below 35 ps RMS, synchronizing two TDCs using the White Rabbit protocol and a 30 m telecom fiber. We developed the data acquisition of the raw time tags, and an algorithm to compute the second-order correlation function. 1]Université Côte d’Azur, CNRS, Institut de Physique de Nice, France. 2]Instituto de Ciencias Físicas (ICIFI, UNSAM - CONICET), Argentina. 3]Universite Cote d’Azur, Observatoire de la Cote d’Azur, CNRS, Laboratoire Lagrange, France. keywords Intensity interferometry, Single-photon sensors, telescopes, White dwarf, Sirius B, Synchronization † † authorinfo: Corresponding author: Federico Izraelevitch-Patitucci, [email protected] 1 INTRODUCTION The IC4Stars (Intensity Correlation for Stars) project aims to measure the diameter of a white dwarf star for the fist time, using intensity interferometry. In particular, we aim to measure the closest white dwarf, Sirius B, the companion star of Sirius A. According to theoretical predictions, it is expected that Sirius B has approximately the size of the Earth and the mass of the Sun, which yields an angular diameter of \sim 30\,\mathrm{\upmu as} . To be able to resolve the star in the blue spectral range, a telescope separation of approximately one kilometer is needed. To be able to obtain a SNR of about 10 in a few nights of observation at 8-m-class telescopes [ [ 3 ] ], several technical challenges must be addressed. Among them, we can mention: • On-sky operation of single-photon detection with time resolution in the scale of tens of pico seconds. • The synchronization of two instruments coupled to different telescopes, separated \sim 1 km, with a precision better than the time resolution of the photon detectors. • The recording of the raw time tags measured by the instruments and the data management for on-line monitoring and analysis. • The development of a computing-efficient algorithm to calculate the second-order correlation function, g^{(2)} , on-the-fly and in a posterior analysis. • A wavelength multiplexing instrument, capable of separating the incoming star light in several wavelength channels, and to compute the second-order correlation function between wavelength-matching channels of the two instruments. In this work, we report our efforts in the first four technical fronts: time-resolution single-photon detectors, synchronization and clock distribution between two instruments, and data management and computing. In Sec. 2 we describe characterization tests performed on the detectors and on the Data Acquisition System (DAQ), in their respective subsection. In Sec. 3 we describe our setup during an on-sky acquisition campaign at the Epsilon Telescope, C2PU (Observatoire de la Côte d’Azur, Nice) in March 2026. Finally, we present the main conclusions and our future perspectives. 2 Laboratory characterization tests 2.1 Detector characterization Our current instrument prototype is based on the PhotonPix single-photon detectors (Photonscore) [ [ 4 ] ]. This photodetector is based on a photocathode to convert the incoming photons into photoelectrons, and a Microchannel Plate (MCP) as an electron multiplier. According to specifications, these detectors show jitters of some tens of pico seconds, Photon-Detection Efficiency (PDE) of \sim 30 % and a dark count rate below 100 Counts Per Second (CPS). In the MCP section of the detector, a high voltage generates a cascade of collisions inside microscopic channels. The high voltage sets the electric field strength across the MCP stack, directly controlling the gain and the speed of the electron avalanche. As the voltage is increased, the electron multiplication becomes faster and more efficient, which improves timing performance because the output pulses become steeper and more uniform. We studied the jitter of the detector as a function of the Bias Voltage (that can be adjusted via an internal code in the provided software), in a setup described below. One peculiar effect of these detectors is the local saturation. If one impinges a photon stream in a beam of small diameter, for example below 1 mm, a saturation occurs in the MCP at high fluxes. In this situation, the measured count rate is smaller than the number of impinging photons per unit time (times the PDE), and the jitter performance is degraded. Instead, if the same photon stream is broadened into a larger-diameter beam, illuminating the whole sensitive area, then the saturation occurs at a much higher photon flux and the measured count rate matches the number of photons per unit time in the stream (times the PDE). Figure 1 shows the schematic diagram of the characterization experiments. The setup is based on a 1560 nm pulsed laser (Toptica) with a pulse width of 50 fs, an output power of 140 mW, and a repetition rate of 100 MHz. A nonlinear crystal, MgO:PPLN (Covesion), was used to generate the second and third harmonics, 780 nm and 520 nm, respectively. The latter is sufficiently close to our working wavelength of 417 nm, and was our operating wavelength. Once isolated, the 520 nm beam was attenuated and its diamter was controlled using a set of lenses and an iris. With the set of lenses, the beam diameter was broadened to ensure to have an uniform beam at the detector. Figure 1: Characterization block diagram of the setup used to measure the Detector’s Jitter. A femtosecond-pulsed laser and a non-linear crystal are used to generate the probing beam. In Figure 2 , we show two plots. The left-hand side one is the Jitter as a function of the detector internal high-voltage parameter (Bias Voltage code, expressed in Analog-to-Digital Units, ADU). This measurement was performed using a collimated 6-mm-diameter laser beam at a count rate of approximately 2 MCPS. It can be seen that the Jitter decreases with an increasing voltage, and so we decided to operate at the highest bias voltage. The right-hand side plot shows the Jitter as a function of the impinging Beam Diameter, for different count rates, illustrating the local saturation effect previously mentioned. These curves were acquired at maximum bias voltage and at a constant photon stream (constant number of photons per unit time per unit area). As shown, when the beam is distributed in a larger area, the Jitter decreases. At high incident photon rates (above approximately 1.5 MCPS at large beam diameters) the detected count rate starts to drop towards small Beam Diameters. For example, when the curve of 3 MCPS reaches a beam diameter of 3 mm starting from a larger beam, the actual measured count rate is 1.9 MCPS (that is why we truncated the curve at this value). This characterization process was repeated for all the detectors used on-sky, and we report here a typical behavior. Figure 2: Left: Detector Jitter as a function of the bias voltage, expressed in Analog-to-Digital Units, ADU (an internal code of the software that controls the

Read the complete text