Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities
Mihael Makek, Ana Marija Kožuljević, Tomislav Bokulić, Darko Grošev, Zdenka Kuncic, Siddharth Parashari, Luka Pavelić · 2026
Read Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities by Mihael Makek, Ana Marija Kožuljević, Tomislav Bokulić, Darko Grošev, Zdenka Kuncic, Siddharth Parashari, Luka Pavelić (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-25804.txt.
Introduction
PET scanners image the body from pairs of gamma rays born when positrons annihilate. Those two photons are quantum entangled, their polarisations locked at right angles. Mihael Makek and colleagues built a demonstrator in 2026 that reads that correlation through Compton scattering. It uses single layer scintillator polarimeters. The question: do entangled events sharpen the picture? They imaged germanium line sources at clinical activities, plus a standard NEMA phantom filled with a gallium solution. Single pixel events set the reference image quality.
Single pixel resolution came out at about two and a half millimetres. Polarisation correlated Compton events resolved between roughly three point six and four point nine millimetres, depending on selection cuts, but carried up to twenty percent more signal over random background. The phantom scan combined both event types. The team estimate up to ten percent more sensitivity is available from the entangled events while keeping image quality high.
Catalog record
| CREATOR | Mihael Makek, Ana Marija Kožuljević, Tomislav Bokulić, Darko Grošev, Zdenka Kuncic, Siddharth Parashari, Luka Pavelić |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 29 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.25804
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities Mihael Makek, Ana Marija Kožuljević, Tomislav Bokulić, Darko Grošev, Zdenka Kuncic, Siddharth Parashari, Luka Pavelić Abstract In Positron Emission Tomography, a potential, yet unutilized enhancement, may come from exploiting the quantum entanglement of the annihilation quanta, inscribed in the correlation of their polarizations. To investigate this, we built a PET demonstrator capable of measuring polarization correlations of annihilation quanta by their Compton scattering, based on single-layer scintillator polarimeters. We present a detailed study of the imaging of two 68 Ge line sources, 45 MBq each, to extract the spatial resolution and assess image quality. The results show that a spatial resolution of 2.5 ± \pm 0.1 mm is obtained using single-pixel events, while resolutions obtained with polarization-correlated Compton events range from 3.6 ± \pm 0.3 mm to 4.9 ± \pm 0.3 mm, depending on data selection criteria. We also found that the polarization-correlated Compton events exhibit up to 20% higher average signal to random background ratio compared to the single-pixel events. We also present the first imaging of the NEMA NU-4 phantom filled with a 68 Ga solution of 378 MBq initial activity, successfully combining polarization-correlated events with conventional single-pixel event selection. Based on the extracted spatial resolution, signal-to-background, signal-to-noise, contrast, and contrast-to-noise ratio, we estimate that up to 10% sensitivity increase may be attained by exploiting the polarization-correlated events, while preserving a high image quality. Keywords: Positron Emission Tomography; quantum entanglement; photon polarization; NEMA NU-4 phantom; spatial resolution; image quality Introduction Positron emission tomography (PET), an irreplaceable diagnostic tool for medical imaging, is based on the coincident detection of two gamma photons originating from positron annihilation in patient’s body. The gamma photons are typically detected by scintillation detectors capable of measuring photon energy, time of arrival and hit position. PET has been continuously improved in terms of sensitivity and image quality by advancing both detector components and image reconstruction methods, leading to shorter acquisition times, using lower doses of radiopharmaceuticals and setting ground for imaging radiotracer kinetics 16 ; 24 . In the past decade, the correlation of the polarizations of the gamma rays from positron annihilation has gained interest, initiated by simulation studies suggesting a possibility of enhancing PET 12 ; 15 ; 27 ; 28 . This correlation is a consequence of quantum mechanical properties of the \mathrm{e^{+}e^{-}} system. Conservation of angular momentum and parity following its decay, requires the polarizations of the annihilation quanta to be orthogonal 4 . Moreover, it was postulated 21 ; 25 and confirmed experimentally 30 ; 13 ; 7 that the annihilation quanta represent a quantum-entangled system 2 . This property, not previously utilized in PET, presents an additional opportunity independent of energy criteria, to discriminate true coincidences from random coincidence events, where no correlation is present. The method to determine the polarization plane of a gamma photon is to let it undergo Compton scattering and measure its azimuthal scattering angle, which is related to the initial polarization plane. In the particular case of the back-to-back gamma rays from positron annihilation, where both of them undergo Compton scattering, the joint cross-section is given by 21 , \mathrm{\frac{d^{2}\sigma}{d\Omega_{1}\!d\Omega_{2}}\!\!=\!\!\frac{r_{0}^{4}}{16}\left[F(\theta_{1}\!)F(\theta_{2}\!)-\!G(\theta_{1}\!)G(\theta_{2}\!)cos(2(\phi_{1}-\phi_{2}))\right]} (1) where \mathrm{r_{0}} is the classical electron radius, \mathrm{d\Omega_{1,2}} are the solid angles, \mathrm{\theta_{1,2}} are the Compton scattering angles, and \phi_{1} and \phi_{2} are the azimuthal scattering angles of photon 1 and 2, respectively. The latter of the kinematic factors \mathrm{F(\theta_{1,2})\!=\!\frac{2+(1-cos\theta_{1,2})^{3}}{(2-cos\theta_{1,2})^{3}}} and \mathrm{G(\theta_{1,2})\!=\!\frac{sin^{2}\theta_{1,2}}{(2-cos\theta_{1,2})^{2}}} can be identified as the analyzing powers of polarimeter 1 and 2, respectively, and their product: \mu=\mathrm{G(\theta_{1})G(\theta_{2})} (2) is labeled the modulation factor. Since the measurement of polarization correlations of annihilation quanta is not currently utilized in clinical imaging with PET, the key question is how to implement it cost-effectively. Compton polarimeters need to determine energy and position of the recoil electron and the scattered photon, which is typically achieved using two position sensitive detector layers. However, using multiple detector layers on a large scale, as in the case of a clinical PET camera, would considerably increase the complexity and cost of the apparatus. To avoid this, we implemented the concept of a single-layer detector in which a single segmented scintillator matrix is used as the gamma-ray polarimeter, acting as both the Compton scatterer and the absorber. The feasibility of the concept to measure polarization correlation of annihilation quanta was previously demonstrated under laboratory conditions 14 , and further optimized 11 ; 19 . A similar crystal-based concept investigated the utilization of polarization correlations for PET imaging under laboratory conditions 8 . Other approaches to include quantum-entangled Compton events in PET imaging are under investigation using plastic scintillators 17 , and concepts based on Cadium-Zinc-Telluride detectors 23 . This work reports the performance of demonstrational setup, based on the single-layer concept for implementing polarization measurement in PET, and for the first time, presents the corresponding PET images of source distributions with clinically relevant activities, obtained by utilizing polarization-correlated Compton events. Further, we compare these to images obtained by conventional single-pixel event selection in terms of spatial resolution, signal-to-background, signal-to-noise, contrast, and contrast-to-noise, and estimate a sensitivity gain by exploiting the polarization-correlated inter-crystal scatter events. Methods Experimental setup The experimental setup comprised two detector modules based on segmented scintillators coupled to silicon photomultiplier (SiPM) arrays and front-end readout electronics (Figure 1 (a)). Each module had a dedicated cooling device that served a dual purpose of venting the ASICs in the front-end boards and of maintaining stability of the SiPMs’ temperature. The modules were mounted on an aluminum ring supported by mechanical construction, with a sliding platform to position the investigated object in the field of view (Figure 1 (b)). Each module contained 256 GAGG:Ce scintillator crystals with 3.2 mm pitch, assembled from four 8\times 8 detector matrices. The length of the crystals was 20 mm, and their cross sections were 3.0 mm x 3.0 mm in one and 2.9 mm x 2.9 mm in the other module. The 8\times 8 matrices were read out by SiPM arrays (Hamamatsu Photonics, model S13361-3050AE-08), with one pixel of the detector matching one in the SiPM. All modules were tested in the laboratory using a point source as reported by Parashari et al. 19 . The modules were placed on opposite sides of the ring so they could collect annihilation photons in coincidence. The mean energy resolution of the modules at 511 keV was found to be (9.3\pm 2.2) % and (8.1\pm 1.1) %, respectively 19 . Figure 1: Schematic illustration of (a) one detector module consisting of four 8\times 8 crystal matrices, SiPMs, and front-end boards and (b) the experimental setup. The mechanical support structure was engineered to provide a reliable foundation necessary for the imaging process, as well as to enable future upgrades of the system (Figure 1 (b)). It features the gantry, which rotates during the scan to emulate a full ring of detectors. The gantry is supported by four polytetrafluoroethylene (PTFE) rollers and an additional roller is connected to a stepper motor, ensuring precise rotation. The objects (sources) are placed on the platform, which can slide into the field of view. The detector arms mounted on the gantry allow fine tuning of the module position, and they can