Nanosecond-resolved 266 nm Mach-Zehnder interferometry for electron-density measurements of dense plasmas generated in supercritical fluids

Kyusang Cho, Juho Lee, Gunsu Yun · 2026

Read Nanosecond-resolved 266 nm Mach-Zehnder interferometry for electron-density measurements of dense plasmas generated in supercritical fluids by Kyusang Cho, Juho Lee, Gunsu Yun (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-25327.txt.

Introduction

Measuring how dense a laser made plasma is, while it lives for only billionths of a second, takes a probe that barely touches it. Kyusang Cho, Juho Lee, and Gunsu Yun built such a diagnostic in 2026 around an ultraviolet interferometer working at a wavelength of two hundred sixty six nanometres. A laser pulse fires into helium held as a supercritical fluid at one hundred bar, and a split probe beam records phase shifts that reveal electron density frame by frame.

Reconstructing the phase maps and unwrapping the densest shot gave a peak local electron density around two and a half times ten to the eighteenth per cubic centimetre. Careful error checks on absorption, beam bending, and collision effects showed the inferred values could not be off by more than an order of magnitude. The setup proves ultraviolet interferometry works for dense plasmas in high pressure fluids.

Catalog record

CREATORKyusang Cho, Juho Lee, Gunsu Yun
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE37 KB
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2606.25327

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Nanosecond-resolved 266 nm Mach-Zehnder interferometry for electron-density measurements of dense plasmas generated in supercritical fluids Kyusang Cho, Juho Lee, Gunsu Yun Abstract We developed a nanosecond-resolved 266 nm Mach-Zehnder interferometer for electron-density measurements of dense laser-produced plasmas generated in 100-bar supercritical-fluid (SCF) helium. A 1064 nm pump pulse was focused into the SCF helium medium, and the plasma-induced phase shift of a 266 nm UV probe beam was recorded using an ICCD-based interferometric imaging system. Plasma-arm-only and reference-arm-only images were used to normalize raw interferograms and improve the effective fringe visibility. The corrected interferograms were analyzed using a two-dimensional Fourier-transform method to reconstruct phase-shift maps, which were converted into line-integrated electron-density distributions through the plasma dispersion relation. Assuming cylindrical symmetry, Abel inversion was applied to the plasma with the largest line-integrated electron density, yielding a maximum local electron density of approximately 2.5 × 10 18 ​ cm − 3 2.5\times 10^{18}~\mathrm{cm^{-3}} . The measurement fidelity was evaluated by considering free-free absorption of the probe beam, probe-beam refraction by plasma electron density gradients, and effect of finite-collision-frequency effects on the plasma dielectric response. These estimates indicate that the inferred electron density is not altered by more than an order of magnitude under the present experimental conditions. The present system demonstrates the applicability of 266 nm UV interferometry to nanosecond-resolved density diagnostics of dense plasmas in high-pressure supercritical fluids. I Introduction High-energy-density physics (HEDP) is the study of matter under extreme conditions, where the energy density, pressure, and temperature are sufficiently large that ordinary descriptions of ideal plasmas are no longer adequate Drake 2006 . In its 2003 report, the National Research Council identified the exploration of matter under such extreme conditions as one of the major frontiers of contemporary physics National Research Council 2003 . Under these conditions found in Jovian planetary interiors Ichimaru 1982 , white dwarfs Saumon, Blouin, and Tremblay 2022 , and solar photosphere Ichimaru 1977 ; Van Horn 1991 , most materials are ionized and exist as dense plasmas. Unlike ideal plasmas, dense plasmas can enter non-ideal regimes such as strongly coupled plasmas in which the Coulomb interaction energy becomes larger than the thermal energy, and degenerate plasmas in which the Fermi energy exceeds the thermal energy Ichimaru 1977 . These regimes are commonly characterized by the Coulomb coupling parameter, \Gamma=\frac{e^{2}}{4\pi\epsilon_{0}ak_{B}T_{e}}, (1) and the degeneracy parameter, \Theta=\frac{k_{B}T_{e}}{E_{F}}, (2) where a is the Wigner-Seitz radius, k_{B} is the Boltzmann constant, T_{e} is the electron temperature, \epsilon_{0} is the vacuum permittivity, and E_{F} is the Fermi energy. In these regimes, ionization balance, transport, opacity, and equation of state can deviate substantially from those of ideal plasmas Ichimaru 1982 . Recent advances in high-power lasers, pinch experiment facilities, and accelerators have made it possible to generate high-energy-density matter under controlled laboratory conditions, opening new opportunities for experimental studies of dense plasma physics. Despite these advances, accurate diagnosis of dense plasmas remains challenging. The relevant plasma state is often generated only transiently, typically on time scales shorter than a nanosecond, and the plasma can exhibit high temperature, high density, and significant opacity. These conditions make it difficult to determine the fundamental plasma parameters, such as electron temperature and density. Therefore, time-resolved and quantitatively reliable diagnostics of electron temperature and electron density are essential for experimentally determining plasma states. In dense plasmas, direct diagnostics using probes are generally not applicable because of the transient and dense plasma conditions. As a result, non-intrusive optical diagnostics are commonly used, including optical emission spectroscopy, Thomson scattering Swadling et al. 2014 , and interferometry Harilal and Tillack 2004 . Among these methods, interferometry is a representative electron-density diagnostic. A probe beam passing through a plasma experiences a phase shift caused by the plasma refractive index, and this phase shift can be converted into a line-integrated electron density using the plasma dispersion relation. Interferometric systems can be implemented in various optical geometries, such as Mach-Zehnder Chan et al. 2018 ; Lee et al. 2023a , and Sagnac configurations, and pulsed laser probes enable density measurements with nanosecond or shorter temporal resolution, enabling the probing of transient events. For high-density plasma diagnostics, the probe wavelength is a critical parameter. The critical density of a probe beam is n_{c}=\frac{\epsilon_{0}m_{e}\omega_{\mathrm{0}}^{2}}{e^{2}}=\frac{4\pi^{2}c^{2}\epsilon_{0}m_{e}}{e^{2}\lambda_{\mathrm{0}}^{2}} (3) where \omega_{\mathrm{0}} and \lambda_{\mathrm{0}} are the probe angular frequency and wavelength, respectively. Since n_{c}\propto\lambda_{\mathrm{0}}^{-2} , shorter wavelengths allow higher-density plasmas to be diagnosed before the probe approaches the cutoff condition Da Silva et al. 1995 . A 266 nm UV probe beam has a critical density of approximately 1.6\times 10^{22}~\mathrm{cm^{-3}} , which is sixteen times larger than that of a 1064 nm laser. This motivates the use of a 266 nm UV probe beam to measure dense helium laser-produced plasmas in high-pressure supercritical fluids. In this work, we develop a nanosecond-resolved 266 nm UV Mach-Zehnder interferometer for dense plasmas generated in 100-bar supercritical-fluid (SCF) helium. The diagnostic system combines UV imaging optics, pump-probe synchronization, fringe correction, and Abel inversion. In addition, we evaluate the fidelity of the inferred electron density against probe absorption, probe refraction, and high collision-frequency effect. II 266 nm UV Mach-Zehnder interferometer II.1 Experimental apparatus Figure 1: Schematic layout of the UV Mach-Zehnder interferometer and experimental conditions. a. Schematic of the 266 nm UV Mach-Zehnder interferometer. A 1064 nm pump laser and a 266 nm probe laser were synchronized to conduct nanosecond-resolved interferometry. The probe beam was separated into two arms: the plasma arm passed through the plasma, whereas the reference arm propagated through air. b. Summary of the experimental parameters, including the medium conditions, imaging conditions, and laser parameters. The experimental procedure consists of two main steps: preparation of the high-pressure SCF medium and laser-plasma generation and pump-probe diagnostics. The medium conditions, imaging conditions, and laser parameters are summarized in figure 1 (b). In the present experiment, 100-bar SCF helium was used as the medium. Helium was chosen because, even if the medium is assumed to be fully ionized without considering physical compression such as radiation compression or shock compression, the corresponding electron density of 4.66\times 10^{21}~\mathrm{cm^{-3}} remains below the critical density of the 266 nm UV probe beam. The 5 bar helium gas was pressurized into a high-pressure chamber up to 100 bar using a compressor. After pressurization, the system was left for at least 30 min before the experiment in order to minimize changes in plasma characteristics caused by non-uniformity of the SCF medium Lee et al. 2022 . Once the 100-bar SCF helium was prepared, pump-probe laser plasma generation and diagnostics were performed. A 1064 nm pump laser with a pulse energy of 600 mJ was focused into the chamber using a plano-convex lens (f = 50 mm). At focus, the beam waist was w_{0}=37~\mu m , corresponding to a peak focal irradiance of approximately 2.5 TW/cm 2 . The focused 1064 nm pump pulse generated a dense helium laser-produced plasma. A 266 nm UV probe beam was synchronized with the 1064 nm pump pulse on a nanosecond timescale using a delay generator. The probe beam was split by a 266 nm beam splitter into two arms: a plasma arm passing through the high-pressure chamber and a reference arm passing through air. The two beams were then recombined by another beam splitter

Read the complete text