Data analysis methods for powder x-ray diffraction intensity under laser-driven dynamic compression at Omega and NIF laser facilities
Marius Millot, Federica Coppari, Amy Lazicki, Jon H. Eggert · 2026
Read Data analysis methods for powder x-ray diffraction intensity under laser-driven dynamic compression at Omega and NIF laser facilities by Marius Millot, Federica Coppari, Amy Lazicki, Jon H. Eggert (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-23602.txt.
Introduction
Millot, Coppari, Lazicki, and Eggert improve how diffraction data from laser driven compression shots are turned into reliable intensities, in a 2026 paper on high pressure physics. Powder x-ray diffraction reveals a material's atomic structure while a laser shock crushes it toward a terapascal of pressure. Two platforms do this work: PXRDIP at the Omega laser and TARDIS at the National Ignition Facility. Extracting faithful intensities from their image plates is delicate.
The authors present analysis methods built into a data package and illustrate them on shock compressed diamond near one terapascal. One trick uses the signal from a collimating pinhole, or from an uncompressed layer in the sample, as an in situ intensity reference. They also detail how to compare data taken with different x-ray sources. A final method corrects for thermal damping, the fading of signal in hot material, when comparing against ambient references.
Catalog record
| CREATOR | Marius Millot, Federica Coppari, Amy Lazicki, Jon H. Eggert |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 62 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.23602
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Data analysis methods for powder x-ray diffraction intensity under laser-driven dynamic compression at Omega and NIF laser facilities Marius Millot, Federica Coppari, Amy Lazicki, Jon H. Eggert Abstract Powder x-ray diffraction (PXRD) under laser-driven dynamic compression is a powerful tool to investigate material response to extreme pressure, temperature and strain rates. Robust PXRD platforms have been developed at kJ and MJ laser facilities worldwide including the Powder X-Ray Diffraction Image Plate (PXRDIP) at the Omega Laser Facility at the Laboratory for Laser Energetics (LLE) and the TARget Diffraction In Situ (TARDIS) at the National Ignition Facility (NIF). Here we present further developments of data analysis methods focused towards improving the fidelity of the PXRD intensity determination for these platforms. We illustrate these methods by discussing how they can be implemented in a data analysis package and applied to shock compression data on diamond near 1 TPa. We discuss using the XRD signal from the collimating pinhole or a layer of un-compressed material in the sample package as in-situ references for XRD intensity. We detail how to compare data collected with different x-ray sources and how to account for thermal damping of XRD signal when comparing XRD from a shock-compressed, hot material with the reference material at ambient. I Introduction The Powder X-Ray Diffraction Image Plate (PXRDIP) platform 30 was initially developed at the Omega 60 Laser Facility at the Laboratory for Laser Energetics (LLE), in Rochester, NY. It was later adapted to the LLE Omega EP Laser Facility and has now been fielded in more than 250 shot-days combining Omega 60 and EP. The TARget Diffraction In Situ 31 ; 32 (TARDIS) at the National Ignition Facility (NIF) in Livermore, CA has been used in more than 200 NIF experiments. Important results obtained with the PXRDIP platform include the discovery of superionic water ice XVIII 24 , of the B2 phase of MgO 4 and studies on the melting line of Ta 18 and MgO 41 . TARDIS highlights include documenting the melting on iron near 1 TPa 19 and the persistence of the diamond structure of carbon under ramp compression to 2 TPa 22 . Figure 1: X-ray diffraction experimental configuration with the PXRDIP diagnostic at the Omega EP laser facility. ( A ) Time-integrated photograph of a steady shock experiment. ( B ) Simplified 3D model. Here, one beam (purple) drives the sample package while up to three beams (blue) are tightly focused onto the secondary target (24 mm away, \sim 23 degrees from normal incidence) to produce an x-ray flash. Image plate detectors line the interior walls of the \rm 50mm\times 50mm\times 75mm PXRDIP shielding box to record the x-ray diffraction pattern. An aperture in the back of the box provides a line of sight for the VISAR velocimetry (VISAR) and pyrometry (SOP) measurements. The standard PXRDIP platform configuration sets the 1D VISAR imaging direction along the x axis i.e. along the vertical axis of the target chamber. This means that VISAR documents the drive planarity along that direction, which corresponds to XRD data on the Up and Down panels (see Section IV.3 ). The z axis is along the VISAR line of sight, oriented towards the VISAR telescope. Although focusing about 10 kJ of ultra-violet laser light down to \sim 1 millimeter diameter enables spatially-uniform, well controlled dynamic compression on samples approximately 100 microns thick, conducting in-situ x-ray diffraction (XRD) measurements remains highly challenging. Among the many challenges to be addressed, one is to accurately determine the diffraction geometry, in other words the relative position of the source, sample, reference materials and each of the image plate detectors and account for the non-standard orientation of the image plate detectors with respect to the diffracted x-rays. In addition, PXRDIP raw data are usually dominated by strong, spatially variable background generated by the 10-50 ns long, high-intensity ( 10^{12-14}W/cm^{2} ) laser ablation drive used to achieve precisely controlled shock or ramp compression. Other difficulties are associated with laser-generated plasma x-ray sources: the significant bandwidth of the plasma line emission contributes to peak broadening, while weaker continuum emission may be bright enough to generate intense Laue diffraction spots if the sample package includes single crystals. Due to these challenges, most studies to date with the PXRDIP and TARDIS platforms focused on documenting the presence of Bragg peaks and determining the diffraction angles to infer the density. Here we build on the PXRDIP data analysis methods 30 as well as refinements developed for TARDIS 31 to improve the fidelity of the PXRD intensity determination. Better constraining XRD intensity determination from PXRDIP and TARDIS experimental data offer promising opportunities to study phase transformation and phase coexistence 25 and may enable identifying subtle phase changes such as isostructural transition to superionic behavior 6 . While several shock studies with PXRDIP or TARDIS have been reported 37 ; 18 ; 41 ; 29 ; 23 the previous descriptions of the PXRDIP and TARDIS platforms 30 ; 31 focused the discussion on ramp compression experiments. Here we illustrate these methods with an experiment on shock compressed diamond near 1 TPa collected at the Omega EP laser facility as an example and by describing in detail their implementation in our AnalyzePXRDIP data analysis package implemented in IgorPro . We note that although the discussion of the analysis methods focus on the PXRDIP experimental platform available at the Omega laser facility, methods are also applicable to the TARDIS diagnostic available at the NIF and should be easily transferable to XRD experiments at the Laser Fusion Research Center (LFRC) 34 . This article is organized as follows. We describe the experimental configuration for Powder X-ray diffraction at Omega EP in Sec. II , and an example dataset on shock compression of diamond near 700 GPa in Sec. III . Sec. IV describes the PXRDIP data analysis workflow, beginning with a discussion of the geometry and raw data (Sec. IV.1 ) and including a discussion of projections of the data into diffraction versus azimuth angle (Sec. IV.2 ) and into diffraction angle versus scattering radius (Sec. IV.3 ). We then discuss XRD intensity corrections applied before background subtraction (Sec. V ), SNIP background subtraction and further intensity corrections (Sec. VI ). Next we describe our post-processing and x-ray diffraction intensity analysis (Sec. VII ) including a discussion on intensity lineouts and fits (Sec. VII.1 ) and XRD intensity scaling by the compressed sample volume (Sec. VII.2 ), by the x-ray source brightness(Sec. VII.3 ) and (Sec. VII.4 ). Finally, we discuss the possibility of using an uncompressed reference layer such as the unshocked layer in a shock compression experiment (Sec. VII.5 ). Note that in this last section we restrict the discussion to the simple case of a monoatomic cubic crystal such as diamond, with an initially polycrystalline material. II Experimental configuration for Powder X-ray diffraction at Omega EP Figure 2: PXRDIP fluorescence shield and x-ray filters. ( A ) Photograph of the Down image plate (IP) before insertion into the PXRDIP box, revealing the presence of a flat, 125 \mu m thick black Kapton filter covering the IP, and a Ta shield positioned to block x-ray fluorescence induced in the IP’s phosphor layer by the intense direct