Polariton spectroscopy at the diamond K-edge via X-ray parametric down-conversion
Fridtjof Kerker, Dietrich Krebs, Xenia Brockmüller, Ankita Negi, Christoph J. Sahle, Blanka Detlefs, Christina Bömer · 2026
Read Polariton spectroscopy at the diamond K-edge via X-ray parametric down-conversion by Fridtjof Kerker, Dietrich Krebs, Xenia Brockmüller, Ankita Negi, Christoph J. Sahle, Blanka Detlefs, Christina Bömer (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-02619.txt.
Introduction
Kerker and co-authors probe polaritons at the diamond carbon K-edge with X-rays. X-ray parametric down-conversion gives access to high-energy polaritons. These arise when down-converted photons hybridize with electronic excitations. The team studies the effect with spectral resolution. The setting is the K-shell absorption edge in diamond.
Clear signatures of polaritonic hybridization appear. A polariton spectral map visualizes them. Theoretical modeling supports the analysis. Coupling at this edge is much stronger than in a prior non-resonant case. It reaches well into the strong-coupling regime. The measurements also yield the refractive index of bulk diamond. It is extracted at high spectral resolution around the carbon K-edge. The work opens a spectroscopic window on light-matter hybrids at X-ray energies.
Catalog record
| CREATOR | Fridtjof Kerker, Dietrich Krebs, Xenia Brockmüller, Ankita Negi, Christoph J. Sahle, Blanka Detlefs, Christina Bömer |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 39 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.02619
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Polariton spectroscopy at the diamond K-edge via X-ray parametric down-conversion Fridtjof Kerker, Dietrich Krebs, Xenia Brockmüller, Ankita Negi, Christoph J. Sahle, Blanka Detlefs, Christina Bömer Abstract It has recently been shown that x-ray parametric down-conversion (XPDC) provides access to high-energy polaritons, resulting from the hybridization of down-converted photons with electronic excitations in a nonlinear medium. Here, we present a spectrally resolved study of this effect around the K-shell absorption edge in diamond. Our results exhibit pronounced signatures of polaritonic hybridization, which we visualize by introducing a polariton spectral map and analyze by help of theoretical modelling. We find that the hybridization at this absorption edge results in substantially higher coupling strength than previously reported for a non-resonant case and reaches well into the strong-coupling regime. In addition, we demonstrate how our measurements of polaritonic XPDC allow us to extract the refractive index for bulk diamond at high spectral resolution around the carbon K-edge. Introduction Nonlinear optics has given rise to a plethora of processes for up- and down-conversion of light [ 8 , 19 , 1 , 23 , 2 , 38 , 22 , 3 ] , which have - in turn - found broad application across science and technology [ 41 , 34 , 61 , 63 , 16 ] . Among these processes, spontaneous parametric down-conversion (SPDC) holds a special place given its fundamentally quantum nature and the unique access to non-classical states of light and matter that it enables: First of all, SPDC provides a source of entangled photon pairs [ 32 , 47 ] , ubiquitously used in quantum technology today [ 59 , 36 , 11 , 37 ] - yet in addition, it also provides a gateway to the quantum hybridization of light with matter resulting in polaritons [ 26 , 6 ] . The intimate connection of parametric down-conversion and light-scattering by polaritons was originally identified by Klyshko at optical wavelengths [ 29 ] and recently transferred to the EUV-regime using x-ray parametric down-conversion (XPDC) [ 30 ] . This development allows for unprecedented studies of strong-coupling phenomena in the EUV to soft x-ray range, where other methods to this end were entirely missing previously. Here, we extend this work further and demonstrate that the analogy with optical polaritons runs deeper still - even allowing for the transfer of techniques like polariton k-spectroscopy [ 14 , 31 , 4 , 12 ] from optical to x-ray wavelengths. Following a brief introduction to our experimental setup for momentum-resolved detection of XPDC, we present down-conversion measurements at the carbon K-edge in diamond. Visualizing these in a two-dimensional polariton spectral map - inspired by optical k-spectroscopy - we find rich features that we address with subsequent theoretical modelling. Finally, we use our model to gain new insights on strong coupling in the soft x-ray regime and demonstrate how it can be used to extract the refractive index of otherwise inaccessible bulk materials. Results Accessing polaritons via XPDC In order to gain (spectroscopic) access to polaritons at EUV and soft x-ray wavelengths, we use the process of x-ray parametric down-conversion (XPDC). This nonlinear scattering process provides a unique mechanism to both launch and probe high-energy polaritons [ 30 ] , which is schematically illustrated across Fig. 1 . During XPDC, an x-ray pump photon ( \bm{k_{p}} ) spontaneously splits into a highly-correlated pair of lower-energy photons - the signal ( \bm{k_{s}} ) and the idler ( \bm{k_{i}} ). For highly asymmetric splitting ratios, the idler photon’s energy ( \hbar\omega_{i} ) can be within the soft x-ray regime, where it is readily absorbed by the surrounding sample. Subsequent re-emission and -absorption will lead the idler photon to hybridize with electronic excitations of its environment, forming a polaritonic state (illustrated by circular arrows in Fig. 1 a). While this idler polariton is ultimately lost to detection, signatures of its hybridization remain imprinted onto the scattered signal photon, owing to the strong correlation of the XPDC photon-pair [ 30 ] . These imprints are particularly pronounced, if the idler energy is tuned to electronic resonances or excitation edges, where the associated polaritonic signatures exhibit variegated features that we shall explore in detail for the carbon K-edge in diamond below. Figure 1 : Emergence and detection mechanism of polaritons via XPDC: (a) The pump photon ( \bm{k_{p}} ) spontaneously splits into a correlated photon pair of lower energies, the signal ( \bm{k_{s}} ) and idler ( \bm{k_{i}} ). Subsequent absorption and re-emission of the EUV-idler quantum within the material forms the polariton - a hybridization of photonic and electronically excited states. The higher-energy signal photon is diffracted and carries imprints of this polariton. (b) Phase matching condition for XPDC, with the pump photon ( \bm{k_{p}} ) diffracting nonlinearly off the reciprocal lattice vector ( \bm{G} ) and splitting into the signal ( \bm{k_{s}} ) and the idler ( \bm{k_{i}} ). Rotation symmetry causes emission into cones (green for the signal, purple for the idler). (c) The experimental realization of XPDC has the pump photon impinging on the diamond sample under an angle \Omega with respect to the selected lattice planes. The generated signal cone ( \bm{k_{s}} , green) is reflected by the analyzer, filtering at \hbar\omega_{s}=9.69 keV while suppressing scattering processes at other energies. The analyzer’s spherical shape preserves the momenta of the signal cone and images it onto a 2D detector positioned out-of-focus, thus resolving the scattering signature along both axis 2\theta and \chi . For the XPDC process to occur, energy has to be conserved among the produced photon pair \omega_{p}\Rightarrow\omega_{s}+\omega_{i} . Together with momentum conservation \bm{k_{p}}+\bm{G}=\bm{k_{s}}+\bm{k_{i}} , this constitutes the so-called phase-matching condition (cf. Fig. 1 b). Here, \bm{G} denotes a reciprocal lattice vector of the crystalline sample, on which the nonlinear scattering takes place. Furthermore, all photon energies are connected to their pertaining wave vectors via dispersion relations of the usual form \omega_{j}=\hbar c\,|\bm{k_{j}}|/n_{j} , wherein the refractive index is trivial for the hard x-ray photons ( n_{p}\approx 1\approx n_{s} ) but turns out to be influential for the soft x-ray idler photon. Combining the above conditions allows for signal and idler photons to be produced on opposing cones, as energy conservation only fixes their magnitudes |\bm{k_{s}}| and |\bm{k_{i}}| but leaves a rotational degree of freedom for the emitted wave vectors around the joint vector \bm{k_{s}}+\bm{k_{i}} (Fig. 1 b). Detecting the signal cone ( \bm{k_{s}} ) results in circular scattering patterns that are characteristic of XPDC and provide access to the underlying high-energy polariton. To image these signatures, we employ a momentum resolved detection scheme analogous to our previous work [ 30 ] . As visualized in Fig. 1 c, the scheme centers on a spherically-bent crystal analyzer (SBCA) used in combination with a 2D pixel detector. The signal cone is Bragg-reflected by the SBCA, which refocuses it and simultaneously acts as an energy filter. Here, we use a Si(660) SBCA, bent at 1 m radius and operating at a fixed backscattering energy of \hbar\omega_{s}=9.69\penalty\ \text{keV} . To image the energy-filtered signal, we position the detector before the analyzer’s focal plane and are, thus, able to record the full angular distribution of scattered photons [ 30 ] . In this scheme, we denote the in-plane scattering