First results of a high sensitivity and transportable Ring Laser Gyroscope
A. Basti 1,2 , G. Carelli 1 , G. Di Somma 2 , A.D.V. Di Virgilio 2 , F. Fuso 1 , R. Macchia 3 , E. Maccioni 1,2 , P. Marsili 1 , and A. Pasqualetti 3 · 2026
Read First results of a high sensitivity and transportable Ring Laser Gyroscope by A. Basti 1,2 , G. Carelli 1 , G. Di Somma 2 , A.D.V. Di Virgilio 2 , F. Fuso 1 , R. Macchia 3 , E. Maccioni 1,2 , P. Marsili 1 , and A. Pasqualetti 3 (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-02594.txt.
Introduction
Basti and co-authors report first results from TRIO, a transportable ring laser gyroscope. The work sits inside the GINGER project. GINGER plans an array of large ring laser gyroscopes at the Gran Sasso underground laboratory in Italy. The goals span fundamental physics tests and geophysics. A new design cuts spurious rotation of instrumental origin. Spacers let the cavity side grow from 1.5 up to 5 meters.
TRIO is the prototype, with a side length of 1.52 meters. It was conceived as a movable instrument. The team measures Earth's angular velocity with it. Results test both the prototype's performance and the design behind GINGER. Data are compared with older gyroscope prototypes. The large GINGERINO gyroscope, already running at Gran Sasso, is one reference. The readings support the path toward the full array.
Catalog record
| CREATOR | A. Basti 1,2 , G. Carelli 1 , G. Di Somma 2 , A.D.V. Di Virgilio 2 , F. Fuso 1 , R. Macchia 3 , E. Maccioni 1,2 , P. Marsili 1 , and A. Pasqualetti 3 |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 31 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.02594
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
First results of a high sensitivity and transportable Ring Laser Gyroscope A. Basti 1,2 , G. Carelli 1 , G. Di Somma 2 , A.D.V. Di Virgilio 2 , F. Fuso 1 , R. Macchia 3 , E. Maccioni 1,2 , P. Marsili 1 , and A. Pasqualetti 3 Abstract . Within the frame of the GINGER project, aimed at installing an array of large frame ring laser gyroscopes for fundamental physics tests and as part of a geophysics observatory located in the underground laboratory at Gran Sasso, Italy (LNGS-INFN), we are developing a ring laser gyroscope design to reduce spurious rotation of instrumental origin and the ability to extend the cavity perimeter from 1.5 up to 5m, thanks to the implementation of suitable spacers. The new design led to a prototype, called TRIO, with a side length of 1.52 m, conceived as a transportable instrument. The present paper reports on several preliminary measurements of the Earth angular velocity carried out with TRIO. Results have the twofold objective to assess the instrument performance in the present geometrical configuration and to test validity of the design in view of the GINGER project. To this aim, data obtained with TRIO are compared to typical data acquired with other, previously made, gyroscope prototypes, including the large frame GINGERINO already in operation at the Gran Sasso underground site. 1 Introduction Knowledge of absolute angular velocity is of large importance for fundamental physics, geophysics, and space applications. Among the instruments enabling its accurate measurement, eminent position have Ring Laser Gyroscopes (RL or RLG), in particular Middle or Large Frame Ring Laser Gyroscopes (LF-RLG), with typical perimeters above 6-8m, have demonstrated a sensitivity in the prad/s range for a measurement duration of 1 s [ 13 , 16 , 25 , 24 ] . The GINGER project, presently under construction as part of a large underground geophysics observatory (UGGS) at Gran Sasso, Italy [ 7 , 1 ] , involves an array of LF-RLGs and aims at fully exploiting the excellent sensitivity of the instruments [ 25 , 24 , 13 ] for geophysics and geodesy, for instance to measure the variations of the Length of Day (LoD), where the expected improvements are mainly for daily and sub-daily periods. However, measurements will be also relevant for fundamental physics, since the Earth rotation is affected by the de Sitter and Lense-Thirring effects and its investigation can unravel occurrence of Lorentz violations [ 1 , 27 , 21 , 2 , 9 ] . RLGs are based on a closed path interferometer consisting of a high finesse optical cavity, usually defined by four mirrors at the vertices of a square. An active medium is contained in the square ring cavity and two counter-propagating laser beams are generated [ 26 ] . Interference of the beams transmitted by each mirror brings information on the non reciprocal effects experienced by the counter-propagating beams. Since the two beams share the same path, differences due to these non reciprocity effects are extremely small. However, if the optical cavity is rotating, an asymmetry is generated between the two propagation directions, leading to an effect proportional to the rotational rate. Such an effect, named after Charles Sagnac and known since more than a century, dominates all other effects and is generally exploited in devices for inertial navigation [ 28 , 20 ] . The RLG signal is a beat note, whose frequency, called Sagnac frequency f_{s} , is proportional to the scalar product between the ring cavity area vector \boldsymbol{A} and the angular velocity \boldsymbol{\Omega} of the ring itself: (1) f_{s}=4\frac{\boldsymbol{A}\cdot\boldsymbol{\Omega}}{P\lambda}\;, where P is the perimeter length of the ring cavity and \lambda the wavelength of light. In the last decade the community involved in developing laser gyroscopes has demonstrated an excellent reliability of the instruments, which can run unattended for months, with sensitivity better than 1 nrad/s. The related technology is now mature and new applicative fields can be explored. They include, among others, space astronomy, where the availability of reliable and high-precision measurements of angular quantities is necessary for navigating and pointing purposes. The X-ray interferometric space telescope XRIstel (to be pronounced kristel), presently under development, will include RLGs onboard [ 22 , 17 ] and open a new discovery field enabling spatially resolved measurement of the coronae of stars tens of light years away, neutron star or black hole-stellar binaries across our galaxy, and supermassive black hole binaries across most of the visible universe. A key point, for both the envisioned new applications and the further increase of instrument performance, is related to the mechanical design of the RLG. Strict requirements on the overall frame stability have in the past led to the development of monolithic architectures, with a frame made of a single block of ultra-low thermal expansion materials, e.g., zerodur, and all components rigidly attached to the same block. While so-conceived instruments have attained sub-prad/s sensitivity [ 25 ] , they exhibit several limitations in terms of cost and integration in complex systems, including those embedded in satellites for astronomy investigations. Heterolithic (HL) configurations, obtained by assembling together the required components, allowing sufficient flexibility in the integration, have also demonstrated, with suitable analysis, very high sensitivity [ 13 ] , showing as well limitation induced by the lack of rigidity of the optical cavity, due to the HL structure. Two HL RLG prototypes are presently operated by our group: GINGERINO [ 4 ] , placed in the Gran Sasso underground INFN laboratories, and GP2 [ 6 ] , located in Pisa INFN laboratories. Few other examples are running in the world [ 18 , 29 , 30 , 24 ] . In HL configurations, details of the experimental setup play a big role, since the instrument response depends on the geometry, see Eq. 1 , and spurious rotations due to environmental induced deformations must be necessarily prevented. Therefore, rigidity and geometrical stability must be ensured by proper mechanical design and appropriate material selection. The use of active controls by piezoelectric actuators (PZT) is also needed to correct residual disturbances, for instance those associated with temperature variations and consequent length changes. Based on our past experience, we have designed the GINGER LF-RLG with the purpose to minimize external forces acting directly on the mirrors and prevent mechanical couplings among mirrors. The materials selected for the frame, gnu gr5 fine granite (MICROPLAN GROUP, https://microplan-group.com/microplan-italia/ ) and silicon carbide, ensure high thermal stability and homogeneity in order to reduce spurious deformations. Moreover, the four mirrors cavity design, chosen for the possibility to use two diagonal light paths for in-situ metrology [ 5 ] , employs top-quality commercial Ultra High Vacuum (UHV)-compatible translators, equipped with remotely controlled actuators (PZT and picomotors, for fine and coarse adjustments, respectively). A distinctive feature of the designed setup is its modularity that allows to scale the side length from 1.5 m to 5 m, and above, owing to the implementation of suitable spacers, see Fig. 1 , to be realized in granite for the central structure, silicon carbide for the spacer, and metallic mirrors boxes and perimeter pipes. A short arm version, composed of the granite central part only, has been built with the main aim to