Polymer-Regulated Freezing of Water Droplets Revealed by Synchrotron X-ray Imaging and Raman Spectroscopy
Hyeonjun An, Bomi Kim, Jae Kwan Im, Min Woo Kim, Seob-Gu Kim, Jae-Hong Lim, Kitae Kim, Joonwoo Jeong · 2026
Read Polymer-Regulated Freezing of Water Droplets Revealed by Synchrotron X-ray Imaging and Raman Spectroscopy by Hyeonjun An, Bomi Kim, Jae Kwan Im, Min Woo Kim, Seob-Gu Kim, Jae-Hong Lim, Kitae Kim, Joonwoo Jeong (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2606-01251.txt.
Introduction
An and co-authors watch how a polymer changes droplet freezing. A polymer in water lowers the freezing point. It also softens the sharp tip that forms on ice. The team uses polyvinyl alcohol in water drops. They track freezing with synchrotron X-ray views. Raman maps add chemical detail at each spot. As polymer content rises, the front slows down.
Frozen drops trap fewer bubbles as content rises. Their tops grow more round in each test case. X-ray views show dark zones in and on the drops. Raman maps prove those zones are rich in polymer. Ice growth thus pushes polymer into patches, not a uniform mix. This may help freeze-casting and cold storage of cells.
Catalog record
| CREATOR | Hyeonjun An, Bomi Kim, Jae Kwan Im, Min Woo Kim, Seob-Gu Kim, Jae-Hong Lim, Kitae Kim, Joonwoo Jeong |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24 KB |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2606.01251
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Polymer-Regulated Freezing of Water Droplets Revealed by Synchrotron X-ray Imaging and Raman Spectroscopy Hyeonjun An, Bomi Kim, Jae Kwan Im, Min Woo Kim, Seob-Gu Kim, Jae-Hong Lim, Kitae Kim, Joonwoo Jeong Abstract Adding a polymer to a sessile water droplet not only lowers its freezing point but also suppresses the tip singularity that forms during its freezing on cold substrates. Here, we employ synchrotron X-ray and Raman imaging to elucidate the spatiotemporal mechanism underlying tip suppression in an aqueous polyvinyl alcohol (PVA) solution, a model polymer solution. As the polymer concentration increases, we observe slower propagation of the freezing front, reduced bubble entrapment, and a progressively more rounded apex across the volumes and molecular weights examined. X-ray tomography reveals that frozen PVA droplets retain low X-ray transmittance domains in their interiors and at the surface, and Raman spectral mapping confirms that these domains correspond to PVA-enriched regions, providing direct evidence of freeze-induced polymer segregation. These findings indicate that PVA is redistributed heterogeneously during water solidification rather than shifting bulk properties homogeneously, providing a spatially resolved framework for interpreting the observed tip blunting and the suppression of discrete bubble entrapment. Our work identifies freeze-induced polymer segregation as a pathway by which a dissolved polymer regulates both the external shape and the internal structure of a freezing droplet, and these findings shed light on potential applications in freezing-based processes such as freeze-casting and cryopreservation. [orcid=0009-0000-5316-6264] [orcid=0000-0002-3952-0287] [orcid=0000-0002-3082-783X] † † credit: Writing – original draft, Formal analysis, Data curation, Investigation, Conceptualization † † credit: Writing – original draft, Formal analysis, Data curation, Investigation † † credit: Data curation, Investigation † † credit: X-ray imaging experiment † † credit: X-ray imaging experiment † † credit: X-ray imaging experiment † † credit: Supervision, Project administration, Funding acquisition † † credit: Writing – original draft, Supervision, Project administration, Funding acquisition, Conceptualization † † corresponding: Corresponding authors. 1 Introduction The freezing of water drives phenomena ranging from climate dynamics in Arctic seawater to the engineered microstructures of freeze-cast materials. This phase transition is governed by a complex interplay of multi-physics processes, including supercooling, latent heat dissipation, interfacial evolution, volumetric expansion, gas rejection, and solute redistribution [ 1 , 2 , 3 , 4 ] . The freezing of a sessile water droplet provides an ideal model system for isolating and studying this complexity. During solidification, the freezing front propagating from the droplet bottom adopts a self-similar spherical shape, while mass conservation and volumetric expansion focus the remaining liquid into a point, producing a characteristic conical apex [ 5 , 6 ] . Simultaneously, dissolved gases rejected by the advancing ice front supersaturate the remaining liquid, leading to bubble nucleation, growth, and entrapment [ 7 , 8 , 9 , 10 , 11 ] . The resulting pore morphologies reflect the delicate interplay among freezing rate, gas diffusion, and capillarity [ 12 , 13 , 14 ] . Thus, the freezing of a neat water droplet has served as a reference for understanding how additives modify its phase transitions and morphology. Polymer additives offer a means to regulate droplet freezing, and an aqueous polyvinyl alcohol (PVA) solution has been a representative model system. PVA, a water-soluble polymer, has been extensively studied for its effects on ice growth and ice recrystallization [ 15 , 16 , 17 , 18 ] . Prior studies have shown that PVA indeed alters freezing-front morphology, creating rough, needle-like, rippled, faceted, or tilted interfaces rather than the smoother fronts observed in neat water [ 19 , 20 , 21 , 22 ] . At the droplet scale, increasing PVA concentration suppresses tip formation and prolongs total freezing time. These phenomena have been explained by changes in the effective density ratio and concentration-dependent thermophysical properties [ 23 ] . Researchers have also noted that the slow diffusion of solute — the polymer rejected from ice — causes persistent concentration gradients to develop ahead of the advancing freezing interface [ 24 , 25 , 26 , 27 ] . Even a universal scaling in freezing dynamics based on competition between viscous stresses, capillarity, and solute transport has been proposed [ 28 ] . Crucially, however, these approaches do not address where the rejected polymer accumulates within the droplet, how it is spatially organized during freezing, or how this dictates the evolving frozen internal structure. Addressing these questions requires a probe that penetrates the polycrystalline ice obscuring the droplet interior, and X-ray imaging has proven well suited to characterizing a range of freezing and solidification processes [ 14 , 29 , 30 , 31 , 32 ] . Here, we bridge this gap by combining synchrotron X-ray and Raman imaging to simultaneously track the evolution of the freezing front, the internal structure, and the polymer redistribution in sessile PVA droplets. By directly resolving both morphology and chemical composition in situ, we reveal that macroscopic bulk properties are insufficient to explain the physics of polymer-modified freezing. Instead, we demonstrate that understanding polymer-regulated freezing fundamentally requires accounting for heterogeneous polymer redistribution during solidification. 2 Materials and Methods Sample preparation We used deionized water of 18.2\text{\,}\mathrm{M\SIUnitSymbolOhm}\text{\,}\mathrm{cm} for all experiments and the following polymers: polyvinyl alcohol ( M_{\mathrm{w}}= 13,000–23,000, 98% hydrolyzed, and M_{\mathrm{w}}= 85,000–124,000, 99+% hydrolyzed; Sigma-Aldrich). The stock solutions of high polymer concentration, with no undissolved residue (e.g., 3 wt%), were diluted to obtain solutions of the target concentrations. A water-cooled and PID-controlled Peltier device controlled the temperature of an aluminum substrate from room temperature down to -15\text{\,}\mathrm{\SIUnitSymbolCelsius} under ambient conditions of 21.7\pm 0.6 \mathrm{\SIUnitSymbolCelsius} and a relative humidity of 57.8\pm 2.6 %. After manually depositing a polymer-solution droplet of a controlled volume ( 1\text{\,}\mathrm{\SIUnitSymbolMicro L}10\text{\,}\mathrm{\SIUnitSymbolMicro L} ) onto the substrate at room temperature, we initiated X-ray imaging and acquired the first image within approximately 15\text{\,}\mathrm{s} . Then, the substrate was cooled to the target temperature at a rate of -2\text{\,}\mathrm{\SIUnitSymbolCelsius}\text{\,}{\mathrm{s}}^{-1} ; the onset of cooling was defined as the time at which the programmed substrate cooling began. X-ray imaging setup and analysis We performed X-ray imaging experiments at the 6C Bio Medical Imaging beamline of Pohang Light Source-II (PLS-II). A monochromatic 14\text{\,}\mathrm{keV} X-ray beam was used, and a 2 mm graphite filter was placed upstream to attenuate low-energy photons, thereby reducing unnecessary dose and mitigating the risk of beam-induced damage to the PVA solution. To assess potential X-ray damage to PVA during freezing and imaging, we compared X-ray tomography results for samples frozen with and without X-ray irradiation during freezing. We found no discernible difference, as shown in Fig. S3. The effective pixel size and exposure time for a typical snapshot were 0.65\text{\,}\mathrm{\SIUnitSymbolMicro m} and 100\text{\,}\mathrm{ms} , respectively; we recorded the freezing process at 10 frames per second. Because of the safety procedure required for hutch evacuation and shutter opening, the time interval between sample placement and acquisition of the first image was approximately 15\text{\,}\mathrm{s} . Flat-field correction was performed using a flat-field (open-beam) image acquired without the sample and a dark image acquired with the X-ray beam off to correct for detector dark noise [ 33 ] . The normalized image was calculated as I_{\text{norm}}=\frac{I_{\text{sample}}-I_{\text{dark}}}{I_{\text{flat}}-I_{\text{dark}}} . Note that we adjusted the overall contrast of the figures in the manuscript only to enhance interfacial visibility, and the raw images