Self-Tuning Regularization for Image Scanning Microscopy
Sofia Agostoni, Lisa Cuneo, Christian Daniele, Giacomo Garré, Laurent Le, Alessandro Zunino, Giuseppe Vicidomini, Luca Calatroni · 2026
Read Self-Tuning Regularization for Image Scanning Microscopy by Sofia Agostoni, Lisa Cuneo, Christian Daniele, Giacomo Garré, Laurent Le, Alessandro Zunino, Giuseppe Vicidomini, Luca Calatroni (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-31426.txt.
Introduction
Agostoni and colleagues offer a self-tuning fix for image scanning microscopy, a fluorescence method that pairs detector arrays with computation to reach ideal confocal sharpness. Its standard iterative reconstructions need early stopping, which often boosts noise and flaws. The team adds explicit regularization inside a Bayesian setup and picks its strength by itself, with no ground truth, giving stable images without hand-set stopping rules.
Catalog record
| CREATOR | Sofia Agostoni, Lisa Cuneo, Christian Daniele, Giacomo Garré, Laurent Le, Alessandro Zunino, Giuseppe Vicidomini, Luca Calatroni |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 116973 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.31426
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Self-Tuning Regularization for Image Scanning Microscopy Sofia Agostoni, Lisa Cuneo, Christian Daniele, Giacomo Garré, Laurent Le, Alessandro Zunino, Giuseppe Vicidomini, Luca Calatroni Abstract Image Scanning Microscopy (ISM) is a fluorescence imaging technique that combines detector-array acquisition and computational reconstruction to achieve the theoretical resolution of an ideal confocal microscope, i.e., one operating with an infinitesimally small pinhole, while maintaining high signal-to-noise ratio. Among the reconstruction methods for obtaining the super-resolved image, multi-image deconvolution (MID) and its extension aimed at preserving the optical sectioning capability of confocal microscopy, known as super-resolution sectioning ISM (s 2 ISM), are among the most widely used approaches. Both methods rely on Richardson–Lucy-type iterative schemes, whose semi-convergent behavior requires empirical early stopping and often leads to noise amplification and reconstruction artifacts. In this work, we introduce a self-tuning explicit regularization framework for both MID and s 2 ISM reconstruction. Within a Bayesian maximum a posteriori formulation, we combine a multi-frame Poisson data fidelity term with explicit sparsity-promoting regularization strategies, considering ℓ 1 \ell_{1} and smoothed total variation penalties as representative examples. We further develop a fully automatic and ground-truth-free strategy for regularization parameter selection by adapting the residual whiteness principle to the multi-frame Poisson setting and introducing a spectral high-pass extension tailored to s 2 ISM. The resulting framework enables stable reconstructions without empirical stopping rules. To demonstrate the proposed framework, we consider first-order optimization schemes based on proximal gradient and mirror descent methods with adaptive backtracking strategies. Experiments on simulated and real fluorescence ISM datasets demonstrate improved reconstruction stability and image quality with respect to unregularized approaches, while enabling robust super-resolution and optical sectioning in low-photon conditions. Keywords Image Scanning Microscopy \cdot Poisson inverse problems \cdot Bayesian reconstruction \cdot Automatic parameter selection 1 Introduction Understanding the structure and dynamics of biological systems at the subcellular scale demands imaging techniques capable of resolving features at or below the optical diffraction limit, while minimizing illumination intensity to preserve sample viability. Laser Scanning Microscopy (LSM) forms the architectural backbone of numerous fluorescence imaging techniques widely deployed in biology 42 , thanks to its high spatiotemporal resolution and quantitative imaging capabilities. Among LSM techniques, Confocal Laser Scanning Microscopy (CLSM) became especially popular for its ability to reject out-of-focus light and achieve superior lateral resolution through the use of a pinhole spatial filter placed in front of the detector. While CLSM can in principle achieve a lateral resolution twice better than the optical diffraction limit in the limiting case of a point-like pinhole 54 , fully closing the pinhole drastically reduces the number of detected photons and compromises the signal-to-noise ratio (SNR), making this theoretical resolution gain inaccessible in practice. Image Scanning Microscopy (ISM) 5 ; 52 ; 39 resolves this fundamental trade-off by replacing the single-element detector with an array of detectors — for example, a 5 \times 5 square single-photon avalanche diode (SPAD) array — each element acting as an independent small-pinhole confocal channel 16 . Following a complete bidimensional raster scan of the sample, the detector array generates a four-dimensional dataset consisting of two spatial dimensions corresponding to the scanning coordinates and two spatial dimensions corresponding to the detector reference system. Equivalently, the dataset can be interpreted as a collection of 25 confocal-like scanned images, one for each detector element, corresponding to spatially shifted views of the same specimen. Because every detector element contributes to photon collection and no pinhole is used to reject photons coming from the out-of-focus planes, the full SNR is preserved. At the same time the geometric diversity across elements encodes complementary spatial information that enables super-resolution reconstruction. ISM thus achieves sub-diffraction lateral resolution and enhanced SNR simultaneously, without increasing illumination intensity or requiring substantial hardware modifications beyond replacing the conventional single-point detector with a detector array. These features make ISM particularly well suited for the live-cell, low-phototoxicity imaging demanded by modern biomedical research. Extracting a single, high-quality super-resolved image from the ISM dataset is the central computational challenge of the technique. A simple approach, known as pixel reassignment (PR), theoretically estimates the shift-vectors between detector images and sums the registered channels 55 . Adaptive pixel reassignment (APR) improves upon this by estimating shift-vectors directly from the data via cross-correlation 16 , providing robustness to optical aberrations and misalignments 53 ; 23 . However, both methods build on the assumption that the detector images are shifted and intensity-rescaled replicas of one another i.e., that they share the same point spread function (PSF). This approximation degrades in realistic imaging conditions, where the PSF varies across detector elements. Moreover, neither PR nor APR explicitly exploits the underlying image formation model or the statistical properties of the measurement noise. A more rigorous approach, introduced in 16 ; 60 , frames ISM reconstruction as a multi-channel (or multi-image) inverse problem. Each detector image is modeled as the convolution of the unknown object with a detector-specific PSF, corrupted by Poisson photon-counting noise. Because SPAD array detectors are essentially free from readout noise and are predominantly limited by photon shot noise, a principled statistical likelihood model can be formulated. Maximum-likelihood estimation via minimization of the Kullback–Leibler (KL) divergence leads to a multiplicative iterative algorithm — Multi-Image Deconvolution (MID) — which generalizes the classical Richardson–Lucy algorithm to the multi-detector ISM setting 60 . By fully accounting for the image formation process and the Poissonian noise statistics, MID outperforms APR in both resolution and SNR recovery. In 60 it was further demonstrated that the redundancy intrinsic to the ISM dataset can be exploited to relax the Nyquist–Shannon sampling criterion by a factor of two, enabling a fourfold improvement in acquisition speed without information loss. A further significant advance was introduced in 61 with the simultaneous super-resolution and optical sectioning ISM framework (s 2 ISM). The key observation underpinning s 2 ISM is that imaging with a detector array inherently embeds axial information 59 : the fingerprint function, which encodes the brightness distribution of each PSF across the detector elements, varies with the axial position of the emitter. Specifically, in-focus and out-of-focus fluorescence distribute differently across the detector array, with central elements collecting primarily in-focus light and peripheral elements increasingly collecting out-of-focus contributions. By modeling the ISM dataset as the superposition of contributions from two discrete axial planes — an in-focus plane of interest and an out-of-focus background plane — and inverting the resulting forward model under a Poisson likelihood, s 2 ISM simultaneously achieves super-resolution, enhanced SNR, and optical sectioning from a single-plane acquisition, i.e., a single two-dimensional raster scan, without any modification to the optical system. Notably, MID can also be generalized to three-dimensional imaging by acquiring an additional axial scan and reconstructing a volumetric image stack. In this case, each reconstructed plane can achieve spatial resolution and optical sectioning performance comparable to s 2 ISM. However, this approach requires a full three-dimensional acquisition, resulting in increased acquisition time and phototoxicity, which substantially limits its applicability to fast live-cell imaging. Despite these advances, a fundamental limitation of both s 2 ISM and MID remains unresolved. These methods inherit the well-known semi-convergent behavior of Richardson–Lucy deconvolution: while early iterations progressively recover high-frequency spatial details and improve image sharpness, continued iteration amplifies noise and leads to overfitted, artifact-laden reconstructions that progressively diverge