A Fully Convolutional Approach to Denoising Structural Dynamics Data from X-Ray Photon Correlation Spectroscopy

Nisar Nellikunnummel, Andi Barbour, Lutz Wiegart, Tatiana Konstantinova, Anthony DeGennaro · 2026

Read A Fully Convolutional Approach to Denoising Structural Dynamics Data from X-Ray Photon Correlation Spectroscopy by Nisar Nellikunnummel, Andi Barbour, Lutz Wiegart, Tatiana Konstantinova, Anthony DeGennaro (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-29975.txt.

Introduction

Nisar Nellikunnummel and four colleagues build a fully convolutional denoiser for two-dimensional maps of changing correlations, shown on X-ray photon data. Unlike fixed-size denoisers, it takes inputs of any size while keeping correlation patterns across varied dynamic regimes. Training uses lab-measured correlation data from NSLS-II beamlines, widened by augmentation to curb overfitting. The model recovers fine dynamic detail in noisy, photon-starved settings while keeping structure true, with metric checks hunting model-made bias. The result gives XPCS work fast denoising under low-dose measurement.

Catalog record

CREATORNisar Nellikunnummel, Andi Barbour, Lutz Wiegart, Tatiana Konstantinova, Anthony DeGennaro
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35784
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.29975

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Fully Convolutional Approach to Denoising Structural Dynamics Data from X-Ray Photon Correlation Spectroscopy Nisar Nellikunnummel, Andi Barbour, Lutz Wiegart, Tatiana Konstantinova, Anthony DeGennaro Abstract We present a fully convolutional denoising autoencoder (FC-DAE) for denoising two-time intensity-intensity correlation functions ( C 2 C_{2} ) in X-ray photon correlation spectroscopy (XPCS). Unlike conventional denoising autoencoders that are typically restricted to fixed input sizes, the FC-DAE accepts inputs of arbitrary dimensions while preserving correlation structures across diverse dynamical regimes. The model is trained using experimentally derived C 2 C_{2} data collected at NSLS-II beamlines, with data augmentation applied to expand the diversity of the dataset and reduce overfitting. The FC-DAE successfully recovers intricate dynamical features in low signal-to-noise conditions while maintaining structural fidelity. To assess reconstruction reliability, we employ quantitative metrics to evaluate structural fidelity and identify potential model-induced bias. Our results demonstrate that the FC-DAE provides robust denoising performance with high computational efficiency, enabling recovery of XPCS dynamics under photon-limited and low-dose measurement conditions. 1 Introduction X-ray photon correlation spectroscopy (XPCS) probes structural dynamics in materials by analyzing intensity fluctuations in coherent X-ray speckle patterns produced by the interference of X-rays scattered from randomly distributed inhomogeneities within the material [ 12 ] . This technique is well-suited for investigating both equilibrium and nonequilibrium dynamics across a wide range of systems. Specifically, XPCS is used to probe mesoscale dynamics in processes such as the aging of glasses [ 3 ] , colloidal gelation [ 4 ] , polymer relaxation [ 2 ] , and the fluctuations of magnetic domains [ 11 ] . The two-time intensity-intensity correlation function, C_{2}(q,t_{1},t_{2}) , is used to quantify the temporal evolution of intensity fluctuations in the scattered X-ray signal. It is defined as: C_{2}(q,t_{1},t_{2})=\frac{\langle I(q,t_{1})I(q,t_{2})\rangle}{\langle I(q,t_{1})\rangle\langle I(q,t_{2})\rangle} (1) where I(q,t) represents the scattered intensity at wave vector q and time t , and <> denotes an ensemble average, typically performed over a range of detector pixels at constant q . C_{2}(q,t_{1},t_{2}) is a two-dimensional matrix that quantifies the correlation between intensities at times t_{1} and t_{2} . The C_{2}(q,t_{1},t_{2}) matrix is symmetric about its main diagonal ( t_{1}=t_{2} ), allowing the raw time coordinates t_{1} and t_{2} to be transformed into physically meaningful axes: the age axis, t_{\text{age}} , and the lag axis, \tau [ 10 ] . The age axis represents the evolution of the system since the start of the measurement and is defined as the average of the two time points, t_{\text{age}}=(t_{1}+t_{2})/2 . The lag axis represents the duration of the measured fluctuations and is defined as the time difference, \tau=|t_{2}-t_{1}| . In the limit of stationary dynamics, C_{2}(q,t_{1},t_{2}) reduces to the one-time correlation function, g_{2}(q,\tau) , by averaging C_{2}(q,t_{1},t_{2}) over the t_{\text{age}} axis at a constant \tau . g_{2}(q,\tau)=\langle C_{2}(q,t_{1},t_{2})\rangle_{t_{\text{age}}} (2) Henceforth, C_{2}(q,t_{1},t_{2}) is denoted as C_{2} , and g_{2}(q,\tau) as g_{2} . The time variables t_{1} , t_{2} , t_{\text{age}} , and \tau are discretized in units of detector frames, corresponding to uniformly sampled time intervals (lags) during XPCS measurements. Thus, all correlation functions are evaluated on a discrete time grid, where the frame index serves as a proxy for physical time (lag time) and can be converted to real time using the known frame acquisition rate. The distinction between equilibrium and nonequilibrium dynamics lies in whether relaxation is time-invariant. In equilibrium, C_{2} depends only on lag time, \tau , leading to a constant relaxation rate and uniform correlation width along the age axis t_{\text{age}} in the C_{2} . In contrast, nonequilibrium dynamics are non-stationary, with relaxation times evolving over t_{\text{age}} , appearing as broadening or narrowing of the correlation profile. They may also include stochastic events, such as avalanches or sudden structural rearrangements, which manifest as discrete breaks or discontinuous dynamics along t_{\text{age}} . To interpret g_{2} physically, it is related to the underlying dynamics through the Siegert relation [ 13 ] : g_{2}=C_{\infty}+\beta|g_{1}(q,\tau)|^{2} (3) where C_{\infty} denotes the baseline and \beta_{0}=\beta+C_{\alpha}-1 ( 0<\beta_{0}\leq 1 ) is the instrumental coherence factor, or contrast. The normalized intermediate scattering function, g_{1}(q,\tau) , encodes the sample dynamics, with different functional forms corresponding to different relaxation behaviors. Consequently, the measured g_{2} is fitted to models appropriate for the dynamics under study. In nonequilibrium systems, where the dynamics evolve with t_{\text{age}} , this relation is applied locally within quasi-stationary regions of the data. In practice, nonequilibrium XPCS analysis often requires slicing C_{2} along the age axis t_{\text{age}} to obtain locally stationary regions suitable for fitting. For noisy data, adjacent slices are typically averaged over an age window \Delta t_{\text{age}} to achieve sufficient signal-to-noise ratio (SNR) for reliable parameter extraction. This approach implicitly assumes that the dynamics remain approximately stationary within \Delta t_{\text{age}} ; however, when this condition is not satisfied, the averaging process reduces temporal resolution and can introduce bias in the extracted parameters. Furthermore, selecting an appropriate binning window often requires expert judgment and becomes increasingly impractical for large datasets. These challenges are further compounded by the inherently noisy nature of experimental C_{2} data. In practice, the dominant limitations arise not only from detector imperfections but, more fundamentally, from photon-limited measurement conditions. As a result, effective denoising methods are essential for improving data quality and enabling reliable extraction of dynamical information. The primary challenges and the role of denoising in addressing them are summarized as follows: • Photon-limited conditions: Limited coherent flux reduces the number of detected photons per frame, such that increasing temporal resolution or probing larger q (smaller length scales) leads to reduced SNR. Denoising enables recovery of meaningful correlation signals under these conditions. • Low-dose measurements: Radiation-sensitive samples often require reduced X-ray exposure to mitigate beam damage, which further degrades SNR. Denoising allows reliable extraction of dynamics while operating at lower dose. • Detector artifacts: Occasional detector-related events, such as hot pixels, can introduce temporally correlated artifacts in C_{2} (e.g., streaks along rows and columns). Denoising helps suppress these distortions and improves overall data fidelity. Conventional denoising methods, such as Gaussian and mean filtering [ 5 , 1 ] , suppress noise by averaging neighboring values, often blurring fine correlation features essential for accurate dynamical analysis. Denoising Autoencoders (DAEs) [ 8 , 9 , 14 ] offer a promising solution by learning the functional form of the dynamic signal obscured by noisy data, enabling effective denoising while preserving the intrinsic dynamics. However, a key limitation of DAEs is their reliance on a fixed latent space, which requires inputs of a fixed size and restricts the model’s flexibility when handling arbitrarily sized data. Additionally, the use of a fixed latent representation introduces significant bias, even when the latent space is relatively large. While DAEs can effectively denoise complex patterns present in the training domain, they face a significant challenge in generalization. Because the latent space of a DAE is shaped by the dynamics represented in the training data [ 14 ] , the model may struggle to generalize to qualitatively different correlation patterns. This highlights two major demerits of the DAE approach: first, the necessity for massive, high-fidelity datasets to populate the latent space; and second, the difficulty of training a single ’universal’ model. Instead, DAEs often require specialized models tailored to specific classes of dynamics, as any signal not explicitly captured

Read the complete text