Read Frequency-Modulated and Single-Tone Excitation to Reveal Vibro-Acoustic Nonlinearities in Loosened Bolted Joints by Berkay Kullukcu, Robin Pianowski, Dina Hannebauer (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-29950.txt.

Introduction

Berkay Kullukcu, Robin Pianowski, and Dina Hannebauer test a sound-and-shake method for loose bolts in rail vehicles. A shaker drives a rig while a sensor and mic listen, with one bolt at zero, one-fifth, two-fifths, and four-fifths preload. A pure tone near resonance makes the loose bolt sprout extra high-frequency peaks. Swept tones across a narrow band split the states further apart. Harmonic power ratios mark the loose state from the four-fifths state by a wide margin, growing wider at higher harmonics.

Catalog record

CREATORBerkay Kullukcu, Robin Pianowski, Dina Hannebauer
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE19627
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.29950

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Frequency-Modulated and Single-Tone Excitation to Reveal Vibro-Acoustic Nonlinearities in Loosened Bolted Joints Berkay Kullukcu, Robin Pianowski, Dina Hannebauer Abstract Preload loss in bolted joints results in alterations of the stiffness, damping, and nonlinearity of the structure, but existing monitoring techniques for rail-vehicle systems are often not capable of combining controlled shaker tests and sensing of nonlinear features. This paper proposes a method for detecting bolt loosening using a vibro-acoustic technique, where the structure is subjected to controlled shaker tests to sense the nonlinear features. A triaxial accelerometer was attached to the demonstrator, a microphone was placed in close proximity, and one of the bolts was tested under 0%, 20%, 40%, and 80% preload conditions. Single-tone and frequency-modulated (FM) signals close to the main natural frequency of 130 Hz, which was identified using sine sweep and narrow-band excitation, were applied to the demonstrator. When the structure was subjected to 130 Hz single-tone excitation, the loose state of the bolt exhibited several additional high-frequency spectral peaks. FM excitation between 125 and 135 Hz further distinguished between the states. Harmonic band power ratios, normalized to the carrier, distinguished between the loose state and the 80% preload state, where the difference between the loose and 80% preload states was 17.5 dB for l = 2 l=2 and 36.5 dB for l = 6 l=6 . Berkay Kullukcu et al. keywords bolt loosening detection, preload loss, rail vehicle structures, frequency-modulated excitation 1 Introduction Bolted joints are commonly used due to their high strength, demountability, and low cost, but they need to be subjected to a preload or clamp force to keep the parts in frictional contact with each other. If the preload is reduced, the joints become loose and start to rattle, losing their stiffness and sometimes accumulating high levels of fatigue. For rail vehicles, this means potential maintenance issues and, in extreme cases, safety-related degradation of the interface subjected to repeated cycles of vibration and shock. In other words, “a tight bolt” means a stiff spring with frictional damping properties, while “a loose bolt” means a soft and nonlinear contact with unpredictable damping properties. As literature proves: “Even with small reductions in preload in a bolted plate assembly, resonances will be affected and noise radiation will be increased before the nut is rotated noticeably.” [1], [2], [3] Rail vehicles have complex patterns of bolted interfaces on the carbody and roofborne structures, which are typically exposed to broadband excitation from track irregularities, curving, and braking/traction events with a tendency to increase transverse motion at the interface. This causes increased rattle and structure-borne noise, altered transference of vibrations, and an increased rate of damage at the interface, although a lack of access makes it difficult to retrofit preload sensors on in-service vehicles. The application of a shaker, a small number of accelerometers, and a microphone is well adapted to this problem, as it is based on measurable changes in dynamic response and sound radiation capabilities that can be achieved with access to in-service vehicles and can be adapted to examine the key resonant bands in body vibration problems and rail vehicle maintenance. [4], [5]–[8] If transverse excitation on the interface is sufficient to produce micro-slip and/or macro-slip, then thread friction can be overcome and rotation of the bolt can occur, leading to loss of preload. This can typically be shown to be the case in the “Junker” transverse vibration configuration. If a lap joint is exposed to transverse excitation, then the two plates will stick and then slip past each other, and each slip event will cause a small amount of unwinding. [2], [4], [9], [10] The test setup for transverse vibrations for both DIN 65151 and ISO 16130 have already been standardized. These standards also define the procedure for comparison and quantification of the clamp force decay under controlled displacement excitation. However, in most monitoring situations, there is no access to the preload/axial force. For example, when working with an existing vehicle or demonstrator, it is easy to attach an accelerometer and position a microphone. However, it is not possible to replace every bolt with a sensing bolt. [9]–[11] The preload state changes the interface state by altering (i) the effective stiffness, (ii) the amount of frictional energy loss (damping), and (iii) the degree of nonlinearity. Research into jointed structures indicates that the primary source of damping at bolted interfaces is caused by micro-slip. For example, when the preload decreases, the interface state changes from sticking to partially slipping, which becomes nonlinear. This results in harmonics and sidebands in the frequency spectrum. [12]–[18] Many studies have already successfully employed various instrumentation schemes, such as strain-sensing bolts, ultrasonic time-of-flight, EMI with piezoelectric patches, and wave propagation. These have proven to be highly sensitive to changes. However, they also add to the complexity. On the other hand, accelerometers and microphones are easy to use and inexpensive. However, their use for quantifying loosening events is less developed. For example, an accelerometer can be fixed to a bracket for easy mounting, and a microphone can be placed at a fixed distance from the interface. This allows repeated experiments with minimal changes to the setup. [2], [19] One of the most common concepts is to analyze the changes in modal parameters or frequency response functions. Modal testing theory offers a direct relationship between frequency response functions and physical parameters. Recent research has demonstrated the ability of even limited accelerometer measurements and machine learning to detect bolt tightness changes. For example, for a swept-sine shaker input, the loosened joint might decrease the peak frequency of the resonance peak and increase the bandwidth of the peak. This can be achieved with peak tracking or frequency response function distance methods. [20], [21]–[26] Percussive and vibration-driven sound changes have also been researched for the detection of bolt looseness. The sound field generated in this case can be considered a measurable “shadow” of the vibration. Various studies have employed approaches ranging from conventional feature engineering to classification and feature selection for effective detection. Some studies have also attempted to relate the sound changes to the actual vibration. For example, the ring-down sound generated in a truss connection due to a strike or other means is a characteristic sound field. With increasing looseness, the ring-down time increases or decreases for various frequencies. [27]–[34] For a system like the bolt interface, where there is a transition from sticking to slipping, there exists a nonlinear modulator. Contact acoustic nonlinearity (CAN) and vibro-acoustic modulation (VAM) have attempted to utilize this phenomenon by detecting higher-order harmonics and sidebands that increase in amplitude with increasing looseness. While the initial approach utilizes a high-frequency signal for this detection, the same phenomenon can be utilized for a shaker-based approach and various frequencies in the audio range for the detection of harmonic distortion and modulation products. For example, a low-frequency tone applied by a shaker to a loose connection will have additional frequency components at integer multiples of the tone (harmonics) or integer multiples of a second frequency (sidebands) in the acceleration and sound spectra. [35]–[38] Current standards and many loosening-focused studies focus on measuring the rate of clamp force reduction with a specified transverse motion, while many studies on structural health monitoring deal

Read the complete text