Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors

Damián L. Corzi, José Lipovetzky, Fabricio Alcalde Bessia, Germán Mato, Andrés Cicuttin, María L. Crespo, Martín Pérez, Mariano Gómez Berisso · 2026

Read Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors by Damián L. Corzi, José Lipovetzky, Fabricio Alcalde Bessia, Germán Mato, Andrés Cicuttin, María L. Crespo, Martín Pérez, Mariano Gómez Berisso (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-29808.txt.

Introduction

Damian L. Corzi and seven colleagues build high-resolution X-ray microtomography on cheap commercial CMOS sensors as direct detectors. A microfocus source in cone-beam layout yields absorption contrast from the sensor's fine detail and phase contrast from shifting the object-to-sensor gap. A flat-field correction counters radiation wear during long runs. Voxel sizes reach a few microns, with detail down to about ten microns in magnified phase mode and about twenty otherwise. Phase contrast reveals soft tissue edges that absorption contrast alone struggles to show.

Catalog record

CREATORDamián L. Corzi, José Lipovetzky, Fabricio Alcalde Bessia, Germán Mato, Andrés Cicuttin, María L. Crespo, Martín Pérez, Mariano Gómez Berisso
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE33473
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.29808

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors Damián L. Corzi, José Lipovetzky, Fabricio Alcalde Bessia, Germán Mato, Andrés Cicuttin, María L. Crespo, Martín Pérez, Mariano Gómez Berisso Abstract This work presents high-resolution X-ray microtomography based on commercial off-the-shelf (COTS) CMOS image sensors as direct detectors. The system uses a microfocus X-ray source in cone-beam geometry, enabling both absorption-contrast imaging, thanks to the sensor’s intrinsic resolution, and phase-contrast imaging, by adjusting the object-to-sensor distance. A dynamic flat-field correction algorithm mitigates radiation-induced sensor degradation during long acquisitions. The setup provides voxel sizes from 3.9 ​ μ ​ m 3.9\,\mu m to 5.2 ​ μ ​ m 5.2\,\mu m , with an effective spatial resolution (FWHM) as fine as 9.6 ​ μ ​ m 9.6\,\mu m in magnified phase-contrast mode ( 1.33 × 1.33\times ) and 21 ​ μ ​ m 21\,\mu m in non-magnified absorption-contrast mode. Phase contrast enhances visualization of soft tissue boundaries that are difficult to visualize using absorption-contrast imaging in the same experimental configuration. I Introduction Commercial off-the-shelf (COTS) complementary metal-oxide-semiconductor (CMOS) image sensors (CIS)—originally designed for capturing visible light in consumer electronics—are an attractive option for high-resolution X-ray imaging as direct-radiation detectors, thanks to their small pixel pitch, high integration density, and low cost [ 1 , 2 , 3 ] . Moreover, this small pixel pitch allows the observation of edge-enhancement fringes when using a microfocus X-ray source, enabling propagation-based phase-contrast imaging of low-attenuation samples with a simpler setup than other phase-contrast techniques [ 4 , 5 ] . In this work, we take advantage of these features to generate high-resolution, three-dimensional tomographic reconstructions from X-ray images obtained with these sensors. We present CIS-based phase-contrast tomography, which improves on conventional absorption-contrast tomography by enhancing the edges of radiographed objects, making sample features visible even when attenuation is negligible, as with small or weakly absorbing samples. This is because absorption contrast and phase contrast depend differently on the atomic number ( Z ). Considering the dual wave-particle nature of light, photon-matter interaction can be described using the complex refractive index n=1-\delta+i\beta , where \beta is associated with material absorption and \delta with the dispersive component [ 6 ] . Although both coefficients decrease significantly with photon energy—except near absorption edges— \beta remains smaller than \delta in the low-energy X-ray range, giving techniques that exploit dispersive phenomena an advantage: enhanced image contrast with reduced energy deposition, and potentially lower radiation dose and sample damage [ 6 ] . Obtaining phase-contrast images requires several geometrical considerations. The interference pattern projected on the sensor must be larger than the pixel pitch; otherwise, its spatial variations are averaged within individual pixels, reducing fringe visibility. Observing this pattern also requires lateral coherence, obtained using microfocus X-ray sources with few-micrometer focal spots [ 7 , 8 ] . Since the fringe size is proportional to the square root of the object-to-sensor distance [ 7 , 4 ] , phase contrast requires moving the object away from the detector. This benefits geometric magnification but also enlarges the penumbra—an effect kept small thanks to the use of microfocus sources. This work demonstrates that a strategic combination of acquisition and correction techniques—dynamic flat-field correction, radiation-hardening compensation, and geometry-driven phase-contrast imaging—can turn a sensor not designed for X-ray detection into a platform capable of phase-contrast tomographic reconstruction, achieved here, to the best of our knowledge, for the first time with a COTS CMOS image sensor. The remainder of the paper describes the experimental methods and materials, presents and discusses the results, and closes with the conclusions. I-A Experimental setup The experimental setup for tomography is shown in Fig. 1 . A constant source-to-sensor distance of 760 mm was kept throughout all experiments, moving the object along the system’s axis to exploit both geometric magnification and phase contrast. All components were arranged horizontally for better mechanical stability. Fig. 1: Experimental setup used for tomographic acquisition. (A) The light-tight, shielded cabinet, divided into two compartments: the sensor and sample stage on the left, and the X-ray source on the right. (B) The sensor. (C) The internal shielding partition, which reduces scattered photons reaching the sensor. (D) The X-ray source. A detailed view of the sample holder is presented below in Figs. 3 and 7 . The entire irradiation setup was placed inside a closed, light-tight cabinet lined internally with at least 1\,\text{mm} of lead for radiation protection. The cabinet was divided into two compartments by a lead wall with a window acting as a collimator, minimizing scattered photons reaching the sensor and significantly improving the Signal-to-Noise Ratio (SNR) of the images. The X-ray source used was a tungsten-anode Microbox Integrated X-ray Source, with a 0.254\,\text{mm} thick beryllium window, manufactured by Micro X-ray Inc. It has a 5\,\mu\text{m} focal spot when operated at power levels below 7.5\,\text{W} , as in the phase-contrast images of this work, and supports continuous operation in the 10 to 90 kV range, with a maximum power of 15 W. The sensor was an onsemi (formerly Micron) MT9M001. This CIS consists of a 1280\times 1024 pixel array with a pixel size of 5.2\times 5.2\,\mu\text{m}^{2} , providing a total active area of 6.66\times 5.32\,\text{mm}^{2} . The small pixel size allows the visualization of interference fringes in a similar geometry as was previously reported in [ 4 ] . The sensor was read and configured using an acquisition platform based on the Arducam UC-425 board and the UC-547 adapter [ 9 ] . The complete image acquisition system is presented in Fig. 1 (B), showing the sensor without the transparent cover included in its original package. Removing this cover is essential to eliminate its attenuation, scattering, and fluorescence effects. The readout platform was mounted on an aluminum plate, facilitating sensor alignment and supporting a lead sheet to shield the readout electronics from Total Ionizing Dose (TID) effects. Due to the small dimensions of the radiographed objects, they were carefully adhered to the tip of a needle mounted on an aluminum SEM pin stub holder. This holder was positioned on a Standa 8MR184(E)-11-22 rotation stage with an angular resolution of 0.015\,^{\circ} . The stage was mounted on a motorized two-axis translation system, which travels along rails to allow easy adjustment of the object-to-sensor distance. Both the rails and the readout platform were mounted on an aluminum optical table to ensure precise projection alignment. To reduce the presence of vibrations in the acquisition system, the optical table was placed on a low-density foam mat. To limit the sensor temperature, a cooling device based on a Tec1-12706 Peltier cell was developed to inject cold air into the cabinet. The cold air enters the sensor compartment, passes through the collimator, reaches the X-ray tube compartment, finally exiting through an opening there and dissipating the heat generated by the system. An external computer controlled the X-ray tube, rotation stage, and image acquisition. To maximize the number of photons collected and reduce shot noise, the exposure time was configured to 1\,\text{s} , the maximum allowed by the sensor. Since the photon flux in this specific configuration typically yields limited statistics for a single 1-second exposure, multiple frames were captured and averaged to reduce shot noise. The CIS analog gain

Read the complete text