Wide-field mid-infrared hyperspectral imaging beyond video rate

Jianan Fang, Kun Huang, Ruiyang Qin, Yan Liang, E Wu, Ming Yan, Heping Zeng · 2026

Read Wide-field mid-infrared hyperspectral imaging beyond video rate by Jianan Fang, Kun Huang, Ruiyang Qin, Yan Liang, E Wu, Ming Yan, Heping Zeng (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-29216.txt.

Introduction

Jianan Fang and colleagues build a fast wide-field infrared hyperspectral imager past video speed. Broadband upconversion of bright light at the Fourier plane feeds a rapid acoustic filter, taking sharp images at 10 kHz on a camera. The imager captures 100 bands in 10 milliseconds at 100 Hz. Angular phase matching enables snapshot work with multiplexing across channels, promising faster imaging. Speed, wide-field use, and broadband coverage open fast study of fleeting events in material and life sciences.

Catalog record

CREATORJianan Fang, Kun Huang, Ruiyang Qin, Yan Liang, E Wu, Ming Yan, Heping Zeng
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE41301
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.29216

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Wide-field mid-infrared hyperspectral imaging beyond video rate Jianan Fang, Kun Huang, Ruiyang Qin, Yan Liang, E Wu, Ming Yan, Heping Zeng Abstract Mid-infrared hyperspectral imaging has become an indispensable tool to spatially resolve chemical information in a wide variety of samples. However, acquiring three-dimensional data cubes is typically time-consuming due to the limited speed of raster scanning or wavelength tuning, which impedes real-time visualization with high spatial definition across broad spectral bands. Here, we devise and implement a high-speed, wide-field mid-infrared hyperspectral imaging system relying on broadband parametric upconversion of high-brightness supercontinuum illumination at the Fourier plane. The upconverted replica is spectrally decomposed by a rapid acousto-optic tunable filter, which records high-definition monochromatic images at a frame rate of 10 kHz based on a megapixel silicon camera. Consequently, the hyperspectral imager allows us to acquire 100 spectral bands over 2600-4085 cm -1 in 10 ms, corresponding to a refreshing rate of 100 Hz. Moreover, the angular dependence of phase matching in the image upconversion is leveraged to realize snapshot operation with spatial multiplexing for multiple spectral channels, which may further boost the spectral imaging rate. The high acquisition rate, wide-field operation, and broadband spectral coverage could open new possibilities for high-throughput characterization of transient processes in material and life sciences. Introduction Hyperspectral imaging is a prominent non-invasive analytical technique that allows for the simultaneous acquisition of both spatial and spectral information Khan2018IEEE ; Gao2015JB . Particularly, mid-infrared (MIR) hyperspectral imaging has attracted increasing attention due to the richness of material and molecular signatures observable in this spectral range Vodopyanov2020Book . Vibrational imaging methods for spectral mapping provide a complementary and more sensitive tool when compared with Raman spectroscopic counterparts Camp2015NP ; Hashimoto2019NC , because infrared absorption offers a much larger cross section than that of Raman scattering Cheng2015Science . Nowadays, MIR spectral imaging technologies have been widely used in chemical, medical, and bio-related fields, such as non-destructive material detection, stand-off gas analysis, and high-throughout environmental monitoring, and label-free biomedical diagnosis Rodrigues2022ABC ; Haase2016JB ; Hermes2018JO ; Shi2020NM . Despite tremendous successes in these applications, MIR hyperspectral imaging has long been plagued by the time-consuming acquisition of the three-dimensional spectral data cubes Baker2014NP , which becomes more pronounced for demanding requirements with high spatial definition and broad spectral bands. The available speed for existing hyperspectral imaging instruments is prohibitively slow for rapid analysis or in situ observations of transient processes, which is pertinent to time-sensitive scenarios including fast characterization of gaseous combustion, high-throughput sorting of biomedical samples, and real-time tracking of living organisms Haase2016JB ; Baier2020PCI ; Chan2012AC ; Hiramatsu2019SA . In this context, there is an urgent need to realize high-speed MIR spectral imaging associated with dense sampling points in both spatial and spectral domains. As a benchmarking technique for chemical imaging, Fourier transform infrared (FTIR) imaging spectrometers have witnessed a tremendous progress over the past decades Pilling2016CSE . To boost the data acquisition speed, FTIR spectral imagers mostly operate in a wide-field fashion based on focal plane arrays (FPAs) Dorling2013TB ; Chan2012AC . However, the limited illumination intensity of commonly-used globar thermal sources may necessitate a long dwell time for detection or an averaging operation for denoising to obtain a better signal-to-noise ratio (SNR) Pilling2016CSE . These procedures inevitably restrict the acquisition rate, especially for large format detectors due to a low divided light flux among each pixel Yeh2015AC . Although measurements with an improved SNR can resort to higher-brightness broadband sources based on synchrotron radiation Martin2013NM or laser supercontinuum Borondics2018Optica , the refreshing speed for the FTIR spectrometer intrinsically suffers from the mechanical scanning required to record interferograms, which leads to a total acquisition time up to minutes Chan2012AC . Recently, an alternative approach based on quantum cascade lasers (QCLs) has emerged to implement MIR spectral imaging at an improved speed due to the agile spectral tuning capability for the light source Yeh2015AC ; Shi2020NM ; Haase2016JB . For instance, the frame rate of QCL-based imaging at a single wavenumber reaches to 50 Hz in 640 \times 480 pixels Haase2016JB , which permits a real-time visualization of datacubes only for several spectral bands. Rapid access of more spectral points is typically comprised with a reduced number of active pixels, thus resulting in a smaller field of view or a degraded spatial resolution Yeh2015AC . Indeed, MIR detectors based either on microbolometers or narrow-bandgap semiconductors have been plagued with high dark noise, low pixel count, and limited frame rate Razeghi2014PR ; Wang2019Small . Such a bottleneck in wide-field acquisition rate is also manifested in the scheme based on a MIR supercontinuum source and an acousto-optic tunable filter (AOTF) Lindsay2016SPIE ; Farries2017SPIE . Specifically, the collection of an image cube of 100 wavelengths and 300k pixels takes as long as 2 seconds Farries2017SPIE . To date, it is still a long-sought-after goal to realize a video-rate MIR hyperspectral imaging at high definition, i.e., reaching a datacube refreshing rate over 24 Hz for a spatial format in a megapixel scale, which calls for faster acquisition and image processing speed. To this end, the so-called upconversion imaging approach has been developed to circumvent the limitations of current MIR direct imagers Barh2019AOP ; Dam2012NP ; Paterova2020SA ; Kviatkovsky2020SA ; Mrejen2020LPR ; Ge2023APN . In this approach, the MIR information is typically transferred to the visible or near-infrared replica, where a sensitive and fast detection can be realized by leveraging high-performance large-bandgap sensors Barh2019AOP . Such upconversion configuration has led to superior room-temperature MIR imaging performances with single-photon sensitivity Dam2012NP ; Wang2021LPR and sub-megahertz frame rate Huang2022NC ; Zheng2023LPR based on high-definition silicon cameras. So far, there has been various schemes proposed to implement the MIR hyperspectral upconversion imaging Barh2019AOP . One straightforward strategy is to employ tunable light sources based on an optical parametric oscillator (OPO) Junaid2019Optica . In this fashion, a video-rate MIR monochromatic operation has been demonstrated in a wide-field mode Junaid2019Optica , yet the achievable spectral imaging speed is limited by the wavelength tuning rate over a wide-spanning spectrum. Notably, QCL sources have been adopted for MIR upconversion spectral imaging, but the reported frame rate is limited by a relatively long acquisition time up to 10 ms due to the low conversion efficiency in the continuous-wave pumping scheme Junaid2018OE . Alternatively, a broadband illumination can be used to capture the full spectral information. However, a scanning procedure and subsequent post-processing are often needed to extract single-wavelength components from the polychromatic upconverted images, such as relying on temperature variation Dam2012NP ; Kehlet2015OL or angular rotation Junaid2018OE of the nonlinear crystal, as well as spatial translation of the object scene Kehlet2015OE . A promising remedy to achieve a faster spectral decomposition has recently been reported based on a visible-band hyperspectral camera, which allows to capture monochromatic images with 640 \times 480 pixels at a frame rate over 100 Hz Zhao2023NC . The total acquisition time is about 8 s for recording a spectral data cube with dense wavelength channels, which is intrinsically limited by the scanning speed of the interior grating. In parallel, other promising architectures for indirect MIR imaging have also been intensively investigated by resorting to photothermal effect within interrogated samples Cheng2015Science ; Yin2023SA ; Bai2019SA or two-photon absorption (TPA)

Read the complete text