Single-photon time-stretch infrared spectroscopy

Ben Sun, Kun Huang, Huijie Ma, Jianan Fang, Tingting Zheng, Yongyuan Chu, Hairun Guo, Yan Liang, E Wu, Ming Yan, Heping Zeng · 2026

Read Single-photon time-stretch infrared spectroscopy by Ben Sun, Kun Huang, Huijie Ma, Jianan Fang, Tingting Zheng, Yongyuan Chu, Hairun Guo, Yan Liang, E Wu, Ming Yan, Heping Zeng (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-29215.txt.

Introduction

Ben Sun and colleagues devise a broadband mid-infrared single-photon time-stretch spectrometer built on upconversion and counting. A broad light spanning 2 to 4 micrometers is converted to the near-infrared band, using fiber and silicon sensors. Photon timing is registered by a low-jitter counter, yielding resolution near half a wavenumber in light well under one photon per nm per pulse. Against earlier spectrometers, the time-stretch design favors single-pixel simplicity and high-throughput acquisition. Reach, sub-wavenumber resolution, and room-temperature use suit lab and life uses.

Catalog record

CREATORBen Sun, Kun Huang, Huijie Ma, Jianan Fang, Tingting Zheng, Yongyuan Chu, Hairun Guo, Yan Liang, E Wu, Ming Yan, Heping Zeng
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35614
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.29215

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Single-photon time-stretch infrared spectroscopy Ben Sun, Kun Huang, Huijie Ma, Jianan Fang, Tingting Zheng, Yongyuan Chu, Hairun Guo, Yan Liang, E Wu, Ming Yan, Heping Zeng Abstract Sensitive mid-infrared (MIR) spectroscopy is highly demanded in various fields ranging from industrial inspection, biomedical diagnosis to astronomical observation. However, the detection sensitivity of conventional MIR spectrometers has been severely limited by excessive noises for existing infrared sensors, which hinders widespread use in photon-scarce scenarios. Here, we devise and implement a broadband MIR single-photon time-stretch spectrometer based on high-fidelity spectral upconversion and time-correlated coincidence counting. Specifically, a nanophotonic supercontinuum illumination covering 2.4-4.2 μ \mu m is nonlinearly converted to the near-infrared band, where low-loss single-mode fiber and high-performance silicon detector can be leveraged to facilitate dispersive operation and sensitive detection, respectively. The arrival time for the dispersed upconversion photons is precisely registered with a low-timing-jitter photon counter, which enables us to obtain a high spectral resolution about 0.5 cm -1 under a low-light-level illumination down to 0.14 photons/nm/pulse. In comparison to previous MIR upconversion spectrometers, the presented time-stretch architecture favors single-pixel simplicity and high-throughput acquisition for the single-photon spectral measurement. The achieved MIR spectroscopic features of broadband spectral coverage, sub-wavenumber resolution, single-photon sensitivity, and room-temperature operation would stimulate immediate applications in material and life sciences. I Introduction Mid-infrared (MIR) spectroscopy has become an indispensable tool to probe distinct rotational and vibrational modes of specific molecules, which is extensively used to identify chemical species and functional groups in material, biology and medicine fields, among others Vodopyanov2020Book ; Fernandez2005NB ; Cheng2015Science . Nowadays, there is a great impulse to develop sensitive MIR spectroscopy to address the increasing need in a variety of photon-scarce applications, such as trace detection Haas2016ARAC , remote sensing Fang2020NC , environmental monitoring Coburn2018Optica , biological examination Shi2020NM , and heritage conservation Daffara2018OLE . In these scenarios, the collected photon flux is stringently limited due to long operation distance, weak backward scattering, or minimized radiation exposure. Consequently, high-contrast spectral measurements imperatively call for highly-sensitive MIR detection that challenges conventional infrared sensors based on narrow-bandgap semiconductors or thermal-type bolometers Razeghi2014PR ; Wang2019Small ; Liu2021LSA . Indeed, typical MIR detectors are facing limitations in high dark current, slow response time, and low operation temperature, thus struggling to implement sensitive and fast MIR spectroscopy Israelsen2019LSA ; Zheng2023LPR . In addition, scanning-free MIR spectrograph usually requires focal plane arrays (FPAs), where the spectral resolution is severely restricted by the low pixel density Razeghi2014PR . Recently, superconducting nanowire detectors have been integrated to implement broadband single-photon spectrometers Cheng2019NC ; Kong2021NL ; Xiao2022ACS , albeit with limited operation wavelengths below 2 \mu m and additional system complexity in cryogenic cooling. Therefore, it remains a long-sought-after quest to realize high-resolution and high-sensitivity MIR spectroscopy at room temperature over a wide spectral range. In this context, an indirect strategy for MIR spectroscopy has been proposed to circumvent the aforementioned limitations of arrayed MIR detectors, where an intermediate process is used to transfer the MIR information into the visible or near-infrared bands for accessing more mature large-bandgap semiconductor technology Barh2019AOP . So far, there have been various approaches to implement the involved frequency transduction step. One common way is based on frequency upconversion of the MIR photons through a high-efficiency and low-noise parametric nonlinear conversion, which allows for demonstrating broadband MIR spectrometers at single-photon sensitivity Dam2012NP ; Mancinelli2017NC ; Cai2022PR ; Huang2022NC or kHz-above frame rates Zheng2023LPR ; Wolf2017OE ; Petersen2018OL . Another promising approach resorts to quantum interferometry of spectrally-entangled photons from spontaneous parametric down conversion (SPDC) Kalashnikov2016NP ; Lindner21OE , which features intrinsic single-photon-level sensitivity. In both methods, the involved spectral analysis is often conducted in the spatial domain based on a monochromator Mancinelli2017NC ; Cai2022PR or a spectrograph Zheng2023LPR ; Wolf2017OE . The former typically requires stringent spectral filtering to obtain a high resolution based on a rotational grating and a narrow slit. The resulting low light throughput may result in a long acquisition time especially at photon-starving circumstances. Alternatively, the latter allows for parallel spectral recording based on a multi-pixel detector. However, the required single-photon array detector is technically challenging and expensive for high-definition pixel formats. Furthermore, the number of spectrally resolved elements is determined by the pixel number, which inevitably leads to a trade-off between spectral coverage and spectral resolution Zheng2023LPR ; Wolf2017OE ; Rodrigo2021LPR . In parallel, optical time-stretch technique has emerged to provide an effective solution to improve the spectroscopic performance, where the spectral components are temporally spread according to the group velocity dispersion (GVD) within a highly dispersive propagation channel Solli2008NP ; Goda2013NP ; Zhou2022LPR . The underlying wavelength-time correspondence facilitates high-throughput and high-resolution spectral measurement via a high-bandwidth single-pixel detector in the time domain Zhou2022LPR . Such time-stretch spectroscopy is initially devised to realize single-shot measurement for capturing non-repetitive or transient events Goda2013NP , which has now been extended to the single-photon regime by combing the time-correlated single photon counting (TCSPC) technique. For instance, the single-photon time-stretch concept has been adopted in photon-pair characterization Avenhaus2009OL ; Eckstein2014LPR ; Davis2017OE ; Yang2020OE , photonic waveform reconstruction Crockett2022LPR , quantum microwave photonics Yang2022SB , single-pixel fluorescence analysis Tiedeck2022ACS , and lightweight Raman spectroscope Meng2015PNAS . However, all these demonstrations are restricted in the near-infrared region. The implementation of sensitive MIR time-stretch spectroscopy is hindered by the deficiencies on low-loss dispersive media and high-sensitivity photon detectors Kawai2020CP . Very recently, upconversion time-stretch infrared spectroscopy has been explored, yet the detection sensitivity is far away from the single-photon level Wen2023LPR ; Hashimoto2023LSA . Intrinsically, the adopted conversion process based on different-frequency generation (DFG) suffers from severe spontaneous parametric noises. To date, it has still been a challenging goal to realize single-photon time-stretch MIR spectroscopy. Here, we have devised and implemented an ultra-sensitive MIR time-stretch spectroscopy based on chirped-pumping sum frequency generation (SFG). The MIR illumination is provided by a turn-key and compact broadband supercontinuum of 2.4-4.2 \mu m based on a nanophotonic silicon nitride (Si 3 N 4 ) waveguide. The involved coherent nonlinear conversion facilitates a high-fidelity spectral translation of the incident MIR field into the near-infrared region in a high-efficiency and low-noise fashion. The upconverted photons are then temporally dispersed by using low-loss single-mode fibers, and detected by a low-timing-jitter silicon photon counter. The coincidence registration for relative time between pump pulses and the detected photons allows for reconstructing the time-stretch infrared spectrum at sub-wavenumber spectral resolution and single-photon detection sensitivity. In contrast to the spatial counterpart, the presented time-domain spectroscopy enables us to implement high-throughput acquisition for parallel spectral components with a single-element detector, which might promote a variety of low-light-level applications in trace inspection, remote sensing, and biomedical examination. II Basic principle The core of the proposed MIR upconversion time-stretch spectroscopy lies in spectro-temporal manipulation of the involved optical fields as illustrated in Fig. 1 . The whole process consists of three major steps: broadband frequency upconversion, time-stretching operation, and coincidence photon counting. The nonlinear conversion is facilitated in pulsed pumping configuration, where the high peak power and the ultrashort pulse duration favor efficiency improvement and noise suppression Zheng2023LPR . As a result of the three-wave mixing process in SFG, one prominent concern for the upconversion spectrometer is the degradation of spectral

Read the complete text