Improving depth-resolution, in-plane contrast, and reducing non-uniformity artifacts for wide-angle DBT
Emil Y. Sidky, Adrian A. Sanchez, John Paul Phillips, Zheng Zhang, Dan Xia, Ingrid S. Reiser, Xiaochuan Pan · 2026
Read Improving depth-resolution, in-plane contrast, and reducing non-uniformity artifacts for wide-angle DBT by Emil Y. Sidky, Adrian A. Sanchez, John Paul Phillips, Zheng Zhang, Dan Xia, Ingrid S. Reiser, Xiaochuan Pan (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-29133.txt.
Introduction
Emil Y. Sidky and colleagues build a two-stage reconstruction algorithm for wide-angle digital breast tomosynthesis with better depth resolution and in-plane contrast. The first stage, a low-resolution sparsity pass for quantitative accuracy, now also estimates a background image absorbing low-frequency artifacts behind image non-uniformity. Tests on three patient cases show the design goals met: sharper depth detail, stronger in-plane contrast, and fewer non-uniformity artifacts. The authors caution that more empirical results and task-based assessment are still needed.
Catalog record
| CREATOR | Emil Y. Sidky, Adrian A. Sanchez, John Paul Phillips, Zheng Zhang, Dan Xia, Ingrid S. Reiser, Xiaochuan Pan |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 32074 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.29133
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Improving depth-resolution, in-plane contrast, and reducing non-uniformity artifacts for wide-angle DBT Emil Y. Sidky, Adrian A. Sanchez, John Paul Phillips, Zheng Zhang, Dan Xia, Ingrid S. Reiser, Xiaochuan Pan Abstract Purpose: This work aims to develop an image reconstruction algorithm for wide-angle digital breast tomosynthesis (DBT) that has improved depth resolution and in-plane contrast while reducing non-uniformity artifacts. Approach: The image reconstruction algorithm is an extension of our prior work on sparsity-regularized iterative image reconstruction. The algorithm is performed in two stages as explained in a prior work. The first stage consists of a low-resolution reconstruction that exploits sparsity for quantitative accuracy. In this work, this first stage is augmented with a formulation that includes the estimation of a “background” image, which absorbs low-frequency artifacts that cause image non-uniformity. Results: The new algorithm is demonstrated on a patient case for which the data are acquired on a wide-angle DBT system. Conclusion: The results on the shown case indicate that the algorithm design goals have been met, but additional empirical results and task-based assessment are needed to strengthen this conclusion. keywords digital breast tomosynthesis, image reconstruction, sparsity regularization * Emil Y. Sidky, \linkable [email protected] 1 Introduction The impact of Professor Barrett’s work on our research is profound and multi-faceted and it would be impossible to detail every instance where his influence was felt. Here, in this special issue article, we focus specifically on our recent line of investigation into sparsity-exploiting image reconstruction for digital breast tomosynthesis (DBT). In this project, we have mainly made use of Chapter 7 “Deterministic Description of Imaging Systems” in the Foundations of Image Science (FIS) [ 1 ] , written together with Dr. Kyle Myers. Understanding the details of this chapter is crucial to anyone who is interested in developing image reconstruction algorithms, because image reconstruction is essentially an inversion of an imaging system model and thus a clear understanding of the types of image system models is necessary. The organization of the paper is as follows: Sec. 2 explains how the taxonomy of imaging system models is utilized to formulate our studies on iterative image reconstruction for limited-data systems such as DBT. Sec. 3 then develops an extension to our previous DBT work that addresses depth resolution, in-plane contrast, and non-uniformity artifacts; and Sec. 4 demonstrates the algorithm on a patient case acquired on a wide-angle DBT system. 2 Imaging system models and sparsity-exploiting image reconstruction in digital breast tomosynthesis Chapter 7 in FIS describes three types imaging system models: continuous-to-continuous (CC), continuous-to-discrete (CD), and discrete-to-discrete (DD). For X-ray tomography, the X-ray and Radon transforms are instances of CC models, where the object model is a continuous function of spatial variables and the measurement space is imagined to be a continuous function of X-ray source angle and detector receptor location. The CD model, however, is a more accurate description for any form of digital imaging because digital detectors consist of discrete arrays of pixels. Finally, the DD model must be contended with because image processing or reconstruction algorithms are implemented on computers, which necessarily discretize images so that they can be stored in memory and manipulated by the various programmed processing units. In addition fully utilizing Dr. Barrett’s taxonomy of imaging models, his emphasis on task-based image quality assessment is felt throughout all of our work on imaging. For analytic image reconstruction, the filtered back-projection (FBP) formulas are derived to be the inverse of the CC divergent-ray or Radon transforms. Because the measured data are discrete, some form of interpolation is implicit when creating the input sinogram to an FBP algorithm. Because interpolation may not perfectly reconstruct the continuous sinogram, the output image values will have error even for ideal, noiseless sinogram measurements. Furthermore, the FBP algorithm can only be executed on a computer for a finite spatial grid. Thus, interpolation is again needed if the display pixel grid does not match the grid of points, which has been reconstructed by FBP. For iterative image reconstruction, the DD model plays a larger role because the scanned object is represented by a finite set of expansion functions, which is most commonly taken to be a grid of voxels. Thus, another source of error is introduced; namely, the divergent-ray transform of a grid of voxels likely does not match the divergent-ray transform of a continuous object function for any set of voxel coefficients. Thus discretization error is an issue with which all iterative algorithms must contend. Turning to sparsity-exploiting image reconstruction in X-ray tomography, we write the cannonical optimization problem for compressive sensing (CS) [ 2 ] \argmin_{f}\|\nabla f\|_{1}\;\;\text{such that}\;\;Xf=g, (1) where f represents the image; g is the sinogram; X is the X-ray, or divergent-ray, transform; and the objective function is the image total variation (TV). This optimization is designed to recover the image f under the assumption that f has a sparse gradient and the sinogram data is ideal; namely the data are generated from the true underlying object f_{0} , i.e. g=Xf_{0} . This CS optimization becomes interesting when the measured data coverage is less than what would be needed for FBP image reconstruction; i.e. the equation Xf=g does not have a unique solution. As of yet, we have not specified the type of imaging model; this optimization can be expressed in CC, CD, and DD forms. It turns out that the vast majority of the work on CS does in fact assume a DD imaging system model; the conditions for recovery of f , discussed in the literature, mainly focus on the number of samples in g being some factor larger than the number of non-zeros in the image gradient. Such conditions only make sense with a DD formulation. Accordingly, \nabla becomes a matrix encoding a finite differencing approximation to the continuous gradient; X is the discretized X-ray transform; g is a set of sinogram samples; and f is a vector of image basis coefficients, most commonly voxel values. For X-ray tomography, the CS optimization problem was originally formulated in CT to address view-angle undersampling, limited angular-range scanning, and cone-beam artifacts from a circular scan, [ 3 , 4 ] but as explained in Pan et al. [ 5 ] CS can address a number of under-sampling issues such as projection truncation, bad detector pixels, and exterior/interior tomography. An important point to understand about all of these sampling challenges is that their degree of difficulty can be tuned for DD imaging system models. Because much CS work focuses on data sampling, mentioning the image basis expansion in passing or perhaps not at all, it leaves the impression that the sampling challenge is being addressed for CC or CD imaging system models and that a continuous image function – or a close approximation thereof – is being recovered. The reality is, however, that DD imaging system models are being employed, and only a finite set of image basis coefficients are being recovered. With this being the case any sampling challenge can be overcome simply by reducing the size of the basis expansion set. The price to be paid is that discretization error increases when performing image reconstruction on real data or simulation data generated with a continuous image model. These issues surrounding DD modeling