Spin Phase Continuous Modulation: A Method for the Measurement of Neutron Monochromaticity Preprint: APS/123-QED
Ryuto Fujitani, Masahiro Hino, Takashi Higuchi · 2026
Read Spin Phase Continuous Modulation: A Method for the Measurement of Neutron Monochromaticity Preprint: APS/123-QED by Ryuto Fujitani, Masahiro Hino, Takashi Higuchi (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-28661.txt.
Introduction
Ryuto Fujitani, Masahiro Hino, and Takashi Higuchi present spin phase continuous modulation, a way to size up neutron beams. Two magnetic fields that swing back and forth wobble neutron spins, letting the method pin down beam speed and monochromaticity. They work out the signal math and test it on a beam with one color. Test and math agree well, letting users gauge beam speed and color purity in numbers.
Catalog record
| CREATOR | Ryuto Fujitani, Masahiro Hino, Takashi Higuchi |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 17363 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.28661
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Spin Phase Continuous Modulation: A Method for the Measurement of Neutron Monochromaticity Preprint: APS/123-QED Ryuto Fujitani, Masahiro Hino, Takashi Higuchi Abstract We present spin phase continuous modulation (SPCM), a new method for characterization of neutron beam properties. By utilizing spin-precession modulation induced by two oscillating magnetic fields, the method enables precise determination of neutron velocity and monochromaticity. We derive a theoretical formulation of the SPCM signal and experimentally validate it using measurements with a monochromatized neutron beam, obtaining reasonable agreement between experiment and prediction. SPCM enables quantitative determination of neutron beam velocity and monochromaticity. I Introduction One of the most important aspects of neutron beam science, including neutron scattering, is accurately determining the velocity of a neutron beam. Beam performance can be evaluated using a criterion called monochromaticity, which is described as \delta v/v . Here, v is the neutron velocity and \delta v is the velocity spread. Since large scale pulsed neutron sources such as J-PARC, SNS and ESS have become operational, measurements of monochromaticity and velocity using time-of-flight (TOF) method have become increasingly important 10 ; 6 ; 12 ; 1 . While the TOF method can measure velocity based on the flight time and path length of neutrons, the instrumental limitations of beamlines cause the measured velocity to exhibit a finite spread. Consequently, the monochromaticity is also a finite value. Therefore, calibration is required for precise TOF measurements, which relies on scattering from well-characterized crystalline references 19 ; 17 ; 16 ; 11 . Although crystal-based calibration is highly precise, it cannot resolve spatial profiles and constrains detector position because it relies on scattered beams. Additionally, the obtained spectrum can only be evaluated over a limited range due to the monochromatization of the crystals. We propose a new method, named as spin phase continuous modulation (SPCM), to measure the monochromaticity and neutron velocity without scattering or monochromatization. SPCM uses spin phase modulation induced by two oscillating magnetic fields (modulators). From the phase and its dispersion of modulation, the velocity and monochromaticity can be measured in high precision. Inspired by methods developed for the precision determination of neutron velocity in fine-structure constant measurements 7 ; 8 ; 9 , SPCM has been developed for the measurement of monochromaticity. The methodology is based on polarized neutron techniques 14 ; 2 ; 13 ; 4 ; 3 ; 20 ; 18 . In this paper, we present a proof-of-principle demonstration of monochromaticity and neutron velocity measurement, along with the corresponding analysis. II Formulation of Spin Phase Continuous Modulation A SPCM system consists of a neutron spin interferometer. The detected neutron count N in a neutron spin interferometer is given by N=\frac{N_{0}}{2}\left\{1-\cos(\chi-\Omega-\delta)\right\}, (1) where N_{0} is the maximum neutron count, \chi is the phase difference between the two resonance spin flippers (RSFs), \delta is the phase shift due to the guide magnetic field applied to maintain the spin orientation and \Omega is the phase induced by a magnetic field between RSFs, corresponding to the spin precession phase. In a SPCM system, two oscillating magnetic fields parallel to the quantization axis are placed between the RSFs. Consider a case in which the modulators are separated by a distance l . When a neutron passes the center of the first magnetic field x=0 at t=\tau , the phase \Omega induced by the magnetic fields is given by \displaystyle\Omega(\tau) \displaystyle=\frac{2|\mu_{n}|}{\hbar v}\left\{\int_{-\infty}^{\infty}B_{0}(x)\sin\!\left(\frac{2\pi f}{v}x+\phi_{1}+2\pi\tau\right)dx\right. (2) \displaystyle\left.\qquad+\int_{-\infty}^{\infty}B_{0}(x-l)\sin\!\left(\frac{2\pi f}{v}x+\phi_{2}+2\pi\tau\right)dx\right\}. Here, \mu_{n} is the magnetic moment of the neutron, \hbar is the Dirac constant and v is the neutron velocity. B_{0}(x) is the magnetic field profile, f is the frequency of the oscillating magnetic fields, and \phi_{1} and \phi_{2} are phases of the fields. Assuming the magnetic fields are zero outside of the RSFs, the range has been extended to infinity. Defining k=2\pi f/v and introducing the Fourier transform of the magnetic field profile in k -space b(k) , defined as |b(k)|e^{i\theta(k)}=\int_{-\infty}^{\infty}B_{0}(x)e^{-ikx}dx, (3) Eq. ( 2 ) can be rewritten as \displaystyle\Omega(\tau) \displaystyle=\frac{2|\mu_{n}|}{\hbar v}|b(k)|\sin\!\left(\frac{\pi f}{v}l+\frac{\phi_{1}+\phi_{2}}{2}+2\pi\tau+\theta(k)\right) (4) \displaystyle\times 2\cos\!\left(\frac{\phi_{1}-\phi_{2}}{2}-\frac{\pi f}{v}l\right). Using the imaginary part of Eq. ( 3 ), Eq. ( 4 ) is derived from Eq. ( 2 ). As neutrons pass continuously, \tau varies with time, and accordingly the phase \Omega(\tau) also changes. This implies that the spin precession phase is modulated by the oscillating magnetic fields, following a sinusoidal function. Thus, the oscillating magnetic fields work as modulators. As a result, the resulting interfernce pattern is N=\frac{N_{0}}{2}\lim_{T\rightarrow\infty}\frac{1}{2T}\int^{T}_{-T}\left\{1-\cos(\chi-\Omega(\tau)-\delta)\right\}d\tau. (5) By defining \theta=2\pi\tau , the integration range can be transformed into a finite interval. \displaystyle N \displaystyle=\frac{N_{0}}{2}\frac{1}{2\pi}\int^{\pi}_{-\pi}\left\{1-\cos(\chi-\Omega(\theta)-\delta)\right\}d\theta (6) \displaystyle=\frac{N_{0}}{2}\left\{1-J_{0}\left(\frac{4|\mu_{n}|}{\hbar v}|b(k)|\cos\!\left(\frac{\Delta\phi}{2}-\frac{\pi f}{v}l\right)\right)\right. \displaystyle\left.\qquad\qquad\times\cos(\chi-\delta)\right\}. Here, \Delta\phi=\phi_{1}-\phi_{2} is introduced. Eq. ( 6 ) shows that the modulation in spin precession phase appears as a change of the contrast in the interference pattern. As a result, periodic contrast change depending on \Delta\phi and \pi fl/v can be obtained. By setting \chi-\delta=\pi , the contrast can be directly obtained from the neutron count. N=\frac{N_{0}}{2}\left\{1+J_{0}\left(\frac{4|\mu_{n}|}{\hbar v}|b(k)|\cos\!\left(\frac{\Delta\phi}{2}-\frac{\pi f}{v}l\right)\right)\right\}. (7) This is the formulation of SPCM signals. SPCM signals can be obtained as neutron count N . According to Eq. ( 7 ), the SPCM signal exhibits peaks when \Delta\phi/2-\pi fl/v=\pi(n+1/2),n\in\mathbb{Z} is satisfied. For a finite neutron velocity distribution, phase dispersion appears in a SPCM signal. As a result, the SPCM signal is smeared along the phase \Delta\phi . When the neutron velocity distribution is expressed as g(v^{\prime}) , the SPCM signal, including the effect of velocity dispersion, can be written as \displaystyle N \displaystyle=\frac{N_{0}}{2}\left\{1+\int g(v^{\prime})\right. (8) \displaystyle\left.\qquad\qquad\times J_{0}\left(\frac{4|\mu_{n}|}{\hbar v^{\prime}}|b(k^{\prime})|\cos\!\left(\frac{\Delta\phi}{2}-\frac{\pi f}{v^{\prime}}l\right)\right)dv^{\prime}\right\}. The neutron velocity distribution is convoluted with SPCM signal. III Experimental Setup for Spin Phase Continuous Modulation To demonstrate the measurement of a neutron velocity and its dispersion using SPCM, we conducted an experiment at JRR-3 C3-1-2-2 (Multilayer Interferometer and reflectometer forNEutron2, MINE2), where monochromated cold neutron beam is available. Figure 1: Experimental setup for spin phase continuous modulation (SPCM) at JRR-3 C3-1-2-2. The experimental setup is shown in FIG. 1 . The beam direction is along the x -axis. The SPCM setup consists, in order from the upstream, of a polarizer, RSF1, RF1, RF2, RSF2, an analyzer, and a neutron detector. A guide magnetic field is applied throughout the entire spin interferometer system to maintain the neutron spin quantization axis. Figure 2: Magnetic field induced by the RF coil for 1 A current The polarizer and analyzer, which reflect only spin-up neutrons, are composed of magnetic multilayer mirrors. The RSFs, which flip the neutrons spin, generate 20 kHz oscillating magnetic fields along the x -axis. RF1 and RF2 generate oscillating magnetic fields along the z -axis to induce phase modulation in spin precession. RF1 and RF2 are constructed by winding a 1.1mm diameter aluminum wire around a 5mm thick acrylic plate. The coil has dimensions of 120 mm in the z -direction (height) and 60 mm in the y -direction (width) and consists of 100 turns. The position of RF1 is fixed on the beam line. RF2 is mounted on a linear stage with a positioning accuracy of 15~\mathrm{\mu m} , allowing adjustment of the distance between RF1 and RF2 in the range from 80 mm to 280 mm. FIG. 2 shows a magnetic field generated at the coil center along the x -axis when a current of 1 A is aplied. This field is