Weight-Guided Constraints for Body Model and Lead Selection in Pediatric CIED MRI Safety Simulations

Safa Hameed, BS 1 2 , Kaylee Henry, PhD 1 , Fuchang Jiang, MS 1 2 , Bhumi Bhusal, PhD 2 , Halley Dillenbeck 3 , Lindsey Gakenheimer-Smith, MD, MScPH 3 , Gregory Webster, MD, MPH 3 , Laleh Golestanirad, PhD 1 2 · 2026

Read Weight-Guided Constraints for Body Model and Lead Selection in Pediatric CIED MRI Safety Simulations by Safa Hameed, BS 1 2 , Kaylee Henry, PhD 1 , Fuchang Jiang, MS 1 2 , Bhumi Bhusal, PhD 2 , Halley Dillenbeck 3 , Lindsey Gakenheimer-Smith, MD, MScPH 3 , Gregory Webster, MD, MPH 3 , Laleh Golestanirad, PhD 1 2 (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-27732.txt.

Introduction

Safa Hameed and colleagues derive weight-based constraints for body model and lead selection in pediatric cardiac device MRI safety simulations. Weight alone separates epicardial from endocardial lead implantation with AUC near nine-tenths, and adding age and height adds nothing. The crossover between approaches sits at 44 kg, far above the commonly cited 10 to 15 kg, with a broad transition zone from 21 to 66 kg.

Catalog record

CREATORSafa Hameed, BS 1 2 , Kaylee Henry, PhD 1 , Fuchang Jiang, MS 1 2 , Bhumi Bhusal, PhD 2 , Halley Dillenbeck 3 , Lindsey Gakenheimer-Smith, MD, MScPH 3 , Gregory Webster, MD, MPH 3 , Laleh Golestanirad, PhD 1 2
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE19043
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.27732

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Weight-Guided Constraints for Body Model and Lead Selection in Pediatric CIED MRI Safety Simulations Thanks: This work was supported under NIH Grants R01EB036272, R01HL168859, and R01EB034377. Safa Hameed, BS 1 2 , Kaylee Henry, PhD 1 , Fuchang Jiang, MS 1 2 , Bhumi Bhusal, PhD 2 , Halley Dillenbeck 3 , Lindsey Gakenheimer-Smith, MD, MScPH 3 , Gregory Webster, MD, MPH 3 , Laleh Golestanirad, PhD 1 2 Abstract Pediatric patients with cardiac implantable electronic devices (CIEDs) face limited MRI access due to RF-induced heating, and computational modeling is increasingly used to characterize this risk. The validity of these simulations, however, depends on pairing body models with clinically realistic lead configurations, guidance that is currently lacking. We retrospectively analyzed 302 CIED surgeries in 281 pediatric patients to derive weight-based constraints for simulation design. Weight alone discriminated epicardial from endocardial lead implantation with AUC = 0.90, and adding age and height yielded no improvement, supporting weight as a sufficient single-parameter selection metric. The probabilistic crossover between approaches occurred at 44 kg, substantially higher than the 10 to 15 kg threshold commonly cited in the literature, with a broad transition zone of 21 to 66 kg in which both lead types were routinely used. Lead length was likewise weight-constrained: only 25 cm leads were observed in patients below 6 kg, and leads of 45 cm or longer were uncommon below 50 kg. These findings yield a three-tier framework, with epicardial-only configurations below 21 kg, dual configurations within 21 to 66 kg, and weight-thresholded lead lengths throughout, enabling MRI safety simulations to focus on clinically realizable anatomy and device combinations. I Introduction Pediatric patients with cardiac implantable electronic devices (CIEDs) face significant barriers to MRI access due to the risk of radiofrequency (RF)-induced heating [ 1 , 2 ] . This risk is driven by the coupling between the MRI transmit field and the implanted lead, a phenomenon highly sensitive to the lead’s trajectory and routing geometry [ 3 , 4 , 5 , 6 , 7 , 8 ] . In pediatric practice, these geometries vary dramatically based on patient size. Surgeons implant epicardial systems, where leads are sutured to the epicardium and connected to an abdominal generator, or electrophysiologists implant endocardial systems, which are routed transvenously to a generator affixed to the pre-pectoral fascia. Because these configurations possess fundamentally different trajectories, they exhibit distinct RF coupling mechanisms [ 3 , 7 , 9 , 10 , 11 ] . While MR-conditional labeling exists for many adult endocardial systems, no epicardial systems have received MR-conditional labeling, limiting pediatric access to MRI [ 12 ] . This regulatory gap forces clinicians to rely on alternative imaging modalities that involve ionizing radiation and may provide suboptimal diagnostic capability [ 13 , 14 ] . Computational electromagnetic modeling is increasingly used to address this gap, allowing researchers to quantify RF heating across device configurations that cannot be exhaustively tested experimentally [ 15 , 16 ] . However, the validity of these simulations depends critically on selecting body models that accurately reflect the patient population for the device being studied. Currently, there is no quantitative guidance linking patient size to lead type or lead length selection. Without such data, researchers risk overlooking clinically important edge cases, such as small infants with unusual systems, or simulating unrealistic scenarios, such as endocardial leads in infants, that rarely occur in clinical practice. Given the high computational cost of these studies, data-driven constraints are needed to focus simulations on clinically relevant anatomy–device combinations [ 17 ] . In this retrospective study of surgical records, we correlated patient size with lead type and length. We converted these findings into simple, weight-based parameters for MRI safety research. These parameters will help engineers select clinically plausible combinations of body models and devices, ensuring their simulations reflect real-world patients. Fig. 1: Pediatric cohort anthropometrics stratified by lead type (surgery-level). Histograms show distributions of (A) age, (B) weight, and (C) height at the time of surgery for epicardial (n = 183) versus endocardial CIED (n = 119) implants. Epicardial implants cluster in younger, smaller patients, while endocardial implants occur predominantly in larger adolescents, motivating size-guided cohort definitions for simulation studies. II Method II-A Data Source We performed a retrospective analysis of pediatric CIED implantations at Ann & Robert H. Lurie Children’s Hospital of Chicago using data from surgical, electrophysiology, and electronic medical records, including a Medtronic device database (“PaceArt”). We linked device-specific parameters with patient anthropometric data at the time of implantation. All analyses were performed on de-identified registry extracts. Patient demographics are summarized in Table I, and distributions of age, weight, and height by approach are shown in Fig. 1. II-B Study Population The length of each epicardial lead is selected by the cardiovascular surgeon at the time of surgery based on clinical judgment that incorporates patient size, the route from the myocardium to the implantable pulse generator (IPG), and practical hospital inventory. Therefore, each surgical procedure was treated as an independent data point. Patients who underwent multiple operations (e.g., system upgrades) contributed multiple observations; results were confirmed in a sensitivity analysis restricted to the first surgery per patient. Inclusion criteria were: (1) age \leq 18 years, (2) documented lead implantation, and (3) complete height and weight data. II-C Variable Definition We extracted patient age, weight, height, and lead parameters (model and length) for each procedure. Leads were classified by model number as epicardial (Medtronic 4965, 4968, and 5071) or endocardial (Medtronic 3830, 5076, 6937A, 6935, 5086, and 6947M), and both pacing and high-voltage (defibrillation) leads were included. Coded registry values were mapped to physical lead lengths (e.g., 25, 35, 45, 52, and 55 cm). To characterize size-dependent selection patterns, we also analyzed a lead-level dataset in which each implanted lead was treated as an independent observation. TABLE I: Patient Demographics by Lead Type All ( n=302 ) Epicardial ( n=183 ) Endocardial ( n=119 ) p Age at implant, years Mean \pm SD 9\pm 6 6\pm 5 14\pm 3 <0.001 Median (IQR) 9 (4–15) 3.9 (1–8) 14 (13–16) Range 0–18 0–18 2–18 Weight, kg Mean \pm SD 36.0\pm 26.0 21.9\pm 18.7 57.7\pm 19.9 <0.001 Median (IQR) 29.6 (13.9–55.3) 15.3 (10.0–28.2) 55.7 (46.3–68.7) Range 1.6–117.5 1.6–89.6 13.0–117.5 Height, cm Mean \pm SD 125.2\pm 40.8 104.1\pm 36.4 157.7\pm 21.2 <0.001 Median (IQR) 133.2 (95.2–161.0) 100.0 (78.7–129.1) 160.0 (148.1–170.5) Range 41.4–197.4 41.4–176.5 65.0–197.4 II-D Statistical Analysis Demographics were summarized using mean \pm standard deviation, as well as median [IQR] (and range where appropriate). Comparisons between epicardial and endocardial groups were performed using Mann–Whitney U tests for continuous variables. Univariate logistic regression was used to evaluate age, weight, and height as predictors of epicardial approach. Discrimination was quantified using the area under the receiver operating characteristic curve (AUC) with 95% bootstrap confidence intervals (1000 iterations). Because pediatric anthropometric variables are highly collinear, we used univariate models to identify the most practical single-variable discriminator for cohort definition and evaluated a multivariable model (age, height, and weight) as a sensitivity analysis. We report a descriptive transition point defined as the predictor value at which the fitted probability of epicardial approach equals 0.50. To provide body-model selection guidance, we computed lead-type-specific weight coverage ranges using the 5th–95th percentiles (covering

Read the complete text