High-resolution mid-infrared single-photon upconversion ranging
Shuhong Jiang, Kun Huang, Tingting Yu, Jianan Fang, Ben Sun, Yan Liang, Qiang Hao, E Wu, Ming Yan, Heping Zeng · 2026
Read High-resolution mid-infrared single-photon upconversion ranging by Shuhong Jiang, Kun Huang, Tingting Yu, Jianan Fang, Ben Sun, Yan Liang, Qiang Hao, E Wu, Ming Yan, Heping Zeng (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-26455.txt.
Introduction
Shuhong Jiang and nine colleagues show a mid-infrared single-photon ranger using upconversion. Sensitive ranging stayed in visible or near-infrared bands, so the team probes the mid-infrared, reading it in a crystal with pump pulses at a different repeat rate. That mismatch scans time in picosecond steps at kilohertz refresh over 50 nanoseconds. The upconverted trace stretches twenty thousandfold for a silicon detector. Time-correlated photon counting brings precision to 4 micrometers at a flux near eight hundred-thousandths of a photon per pulse, far finer than detector jitter.
Catalog record
| CREATOR | Shuhong Jiang, Kun Huang, Tingting Yu, Jianan Fang, Ben Sun, Yan Liang, Qiang Hao, E Wu, Ming Yan, Heping Zeng |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 36928 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.26455
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
High-resolution mid-infrared single-photon upconversion ranging Shuhong Jiang, Kun Huang, Tingting Yu, Jianan Fang, Ben Sun, Yan Liang, Qiang Hao, E Wu, Ming Yan, Heping Zeng Abstract Single-photon laser ranging has widespread applications in remote sensing and target recognition. However, highly-sensitive light detection and ranging (LiDAR) has long been restricted in visible or near-infrared bands. An appealing quest is to extend the operation wavelength into the mid-infrared (MIR) region, which calls for an infrared photon counting system at high detection sensitivity and precise temporal resolution. Here, we devise and demonstrate a MIR upconversion LiDAR based on nonlinear asynchronous optical sampling. Specifically, the infrared probe is interrogated in a nonlinear crystal by a train of pump pulses at a slightly different repetition rate, which favors for a temporal optical scanning at a picosecond timing resolution and a kilohertz refreshing rate over ∼ \sim 50 ns. Moreover, the cross-correlation upconversion trace is temporally stretched by a factor of 2 × \times 10 4 , which can thus be recorded by a low-bandwidth silicon detector. In combination with time-correlated photon-counting technique, the achieved effective resolution is about two orders of magnitude better than the timing jitter of the detector itself, which facilitates a ranging precision of 4 μ \mu m under a low detected flux of 8 × \times 10 -5 photons per pulse. The presented MIR time-of-flight range finder is featured with single-photon sensitivity and high positioning resolution, which would be particularly useful in infrared sensing and imaging in photon-starved scenarios. I Introduction Laser-based light detection and ranging (LiDAR) has been widely used in various areas of science and technology, including autonomous driving, facial recognition, industrial process monitoring, and space debris tracking Kim2021NN ; Kim2020JOSAB ; Steindorfer2020NC ; Riemensberger2020Nature . Among various approaches, time-of-flight (ToF) ranging sets the benchmark for absolute distance metrology, offering high precision, long-range, and fast acquisition Ye2004OL ; Coddington2009NP ; Jiang2020NP ; Na2020NP ; Lee2020Lee . Moreover, single-photon detection has recently been incorporated into the ToF-based LiDAR system based on the time-correlated single-photon counting (TCSPC) technique Pawlikowska2017OE ; Kong2020OL ; Liang2021IEEE . Such photon-counting laser ranging is particularly pertinent to the low-light-level ranging and imaging context Sun2016NC ; Altmann2018Science ; Hadfield2023Optica , for instance, satellite survey, altimetric measurement, and topographic mapping. Notably, further combination with advanced computational algorithms allows for demonstrating long-distance observation over the terrestrial atmosphere Li2021Optica or remote object identification beyond the line of sight Faccio2020NRP . However, these state-of-the-art single-photon ranging performances have so far been limited in the visible or near-infrared regions. Nowadays, there is a significant impulse to extend the operation wavelength of single-photon LiDAR into the mid-infrared (MIR) region, pertaining to unique features of the reduced photon scattering due to relatively long wavelengths Flannigan2022JO and the inherent chemical selectivity based on molecular rovibrational transitions Schliesser2012NP . Specifically, MIR LiDAR within transparency windows of the Earth’s atmosphere favors remote sensing especially at adverse weather conditions such as mist, fog, and haze Walsh2016JL . In virtue of free-space spectroscopy, MIR differential absorption LiDAR (DIAL) systems could facilitate range-resolved investigation of atmospheric gas concentrations Staehr1985AO , which holds great potential for pollution surveillance, leakage warning, and meteorological researches Alvarez2012PNAS ; Girard2015AO ; Yu2021LSA . In these envisioned scenarios, sensitive MIR detection is highly demanded to dramatically improve the working distance and/or reduce the transmitting laser power, which however challenges existing infrared detectors based on narrow-bandgap semiconductors Rogalski2016RPP , bolometer sensors Blaikie2019NC , or emerging low-dimensional materials Wang2019Small . Indeed, the attainable detection sensitivity is typically limited to about pW/Hz 1/2 , which is far away from the single-photon level. Recently, superconducting nanowire detectors have been engineered to access MIR photon-counting capability Marsili2012NL ; Chen2021SB , albeit with consequent trade-off for detection performances and additional system complexity of cryogenic operation. To date, it remains elusive to realize MIR single-photon ranging, which urgently calls for infrared photon-counting systems at high detection sensitivity and high time resolution. In this context, frequency upconversion detection has been proposed to leverage high-performance silicon detectors by spectrally converting the infrared photons into the visible band, which offers desirable features of high detection efficiency, low dark noise, fast time response, and room-temperature operation Barh2019AOP ; Huang2022NC ; Mrejen2020LPR . Consequently, the single-photon upconversion detector has served as an effective tool in a wide range of infrared applications, such as long-distance quantum communication Liao2017NP , quantum-limited optical state characterization Mancinelli2017NC , high-sensitivity spectroscopic analysis Rodrigo2021LPR ; Zheng2023LPR ; Zhao2023NC , high-speed optical coherent tomography Israelsen2019LSA , and phototoxicity-free biological examination Junaid2019Optica . Furthermore, mode selective upconversion detection has recently been configured to facilitate noise-tolerant LiDAR Shahverdi2018OE ; Rehain2020NC , where only the backscattered signal photons in specific time-frequency modes are efficiently converted due to the intrinsic phase-matching requirement Ansari2018Optica . Generally, there are two main categories for the upconversion single-photon ranging. One relies on a continuous-wave pumping upconverter, which is suitable for collecting backscattered photons from non-cooperative targets at an unknown distance. The recorded time correlation between the receiving signal and the trigger enables one to identify the absolute distance information Xia2015OL ; Yue2022RS . But the ranging resolution in the TCSPC configuration is typically limited in the sub-centimeter scale, which is mainly determined by the timing jitter of the detector about tens of picoseconds Widarsson2020AO ; Widarsson2022AO . An alternative scheme resorts to the pulsed pumping upconverter, where the detected photons are precisely time-stamped by the ultrashort optical pulse, thus significantly improving the axial resolution Wang2021PRL ; Potma2021Optica ; Zhang2022PR ; Fang2023LSA . However, the available capture depth is usually confined within tens of centimeters due to a limited travel range of the involved mechanical scanner as the optical delay line Fang2023LSA ; ChenIEEE2023 . Therefore, it necessities the development of novel techniques to address the long-sought-after goal for realizing a high-resolution MIR single-photon LiDAR over a wide operation range. Here we devise and implement a novel MIR upconversion ranging system based on asynchronous optical sampling, which is featured with single-photon sensitivity, high timing resolution, and wide scanning range. Our realization relies on a dual-comb configuration, where the probe and pump lasers are stabilized at slightly different repetition rates. The reflected MIR probe at 3.1 \mu m is asynchronously gated in a nonlinear crystal by the pair-wise ultrashort pump pulse at 1.03 \mu m through the sum frequency generation (SFG) process. Consequently, an all-optical temporal scanning is facilitated at a picosecond timing resolution and a kilohertz refreshing rate over a long capture range of 46.45 ns, which results in a time-stretch cross-correlation trace at the SFG wavelength of 0.77 \mu m. The distance information can be real-time monitored from the waveform detected by a low-bandwidth silicon photodiode. Furthermore, MIR single-photon ranging is demonstrated by combing the TCSPC technique and dual-comb metrology, which permits an extremely low detected flux of 8 \times 10 -5 photons/pulse. Meanwhile, the achieved picosecond temporal resolution is about hundredfold improved over the timing jitter of the used single-photon detector itself, which leads to a high positioning precision of 4 \mu m. As a proof-of-principle demonstration, the MIR photon-counting LiDAR is used to retrieve rich information in thickness, reflectivity, and refractive index for a multi-layered silicon wafer under a low-photon-flux illumination. Notably, our approach alleviates the limitation from the intrinsic timing