A Methodology for Impedance-based Stability Margin Analysis for Interconnected Offshore Wind Clusters
Germano Rugendo Mugambi, Behnam Nouri, Oscar Saborío-Romano, George Alin Raducu, Nicolaos A. Cutululis · 2026
Read A Methodology for Impedance-based Stability Margin Analysis for Interconnected Offshore Wind Clusters by Germano Rugendo Mugambi, Behnam Nouri, Oscar Saborío-Romano, George Alin Raducu, Nicolaos A. Cutululis (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-23030.txt.
Introduction
Mugambi and four coauthors propose an impedance-based method for judging stability margins when a new offshore wind power park joins an existing cluster. Many studies lean on Nyquist encirclements without quantifying margins. Their method evaluates margins at the existing connection after integration and derives a maximum allowable impedance for the new link, so operator margin requirements hold. New Nyquist-based stability regions complement the generalized Nyquist criterion. Vendor-based case studies with two wind plants and an HVDC link validate the approach.
Catalog record
| CREATOR | Germano Rugendo Mugambi, Behnam Nouri, Oscar Saborío-Romano, George Alin Raducu, Nicolaos A. Cutululis |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 40326 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.23030
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Methodology for Impedance-based Stability Margin Analysis for Interconnected Offshore Wind Clusters Germano Rugendo Mugambi, Behnam Nouri, Oscar Saborío-Romano, George Alin Raducu, Nicolaos A. Cutululis Abstract With recent developments in offshore grid architectures, power park modules (PPMs) such as clusters of offshore wind power plants (OWPPs) are increasingly interconnected offshore. Consequently, it is necessary to assess how integrating a new OWPP affects the stability margins of an existing OWPP at the point of connection. Although impedance-based methods are widely used for small-signal stability assessment of interconnected converter-based systems, many studies rely primarily on Nyquist encirclements and do not explicitly quantify stability margins. Thus, this paper proposes a general impedance-based methodology to (i) evaluate the stability margins of an existing connection after a new PPM is integrated and (ii) derive a maximum allowable impedance for the new connection such that the minimum stability margin requirements specified by system operators are satisfied and stable operation is maintained. In addition, new Nyquist-based stability regions are introduced to complement the generalized Nyquist criterion, providing analytical indications of margin compliance and headroom. The proposed method is validated through case studies using vendor-based frequency-domain models of two interconnected OWPPs and HVDC system. I Introduction Recent developments in offshore wind cluster design involve configurations in which the transmission system operators (TSOs) own the offshore transmission infrastructure, and offshore wind power plants (OWPPs) connect directly to the switchgear at the HVDC converter station. This approach is already being deployed at the Ijmuiden Ver wind farm by the TSO TenneT [ 15 ] . A key stability concern for such topologies is the potential for adverse interactions arising from the converter control systems [ 11 ] . Furthermore, it is essential to assess how a new connection affects the stability margins of existing OWPP, which must continue to maintain their stable operation and comply with TSO requirements specified at the Point of Connection (PoC). Among these requirements are limits on phase margins at resonance frequencies [ 14 ] . Impedance-based analysis has emerged as an effective method for addressing small-signal stability challenges in these interconnected converter-based systems. The approach has previously been applied to identify the root cause of harmonic instability in an HVDC connected OWPP [ 3 ] . In the impedance-based approach for grid-connected converters, the overall system is partitioned into source and load subsystems, represented by their small-signal impedances/matrices Z_{s}(s) and Z_{l}(s) , respectively [ 21 ] . The interaction between these two subsystems can be represented as a closed-loop feedback system characterized by the loop gain matrix for multi‑input multi‑output (MIMO) systems or impedance ratio for single-input single-output (SISO) case L(s)=Z_{s}(s)Z_{l}^{-1}(s) . The system stability is evaluated using the Nyquist stability criterion (NSC) by checking whether the Nyquist plot of L(s) encircles the point (-1,0j) ; encirclement indicates instability, while its absence implies stability [ 2 , 6 ] . The application of the NSC assumes that each subsystem is individually stable, i.e., it contains no right-half-plane (RHP) poles. Due to its maturity, well‑defined stability metrics, and compatibility with black‑box converter models, the impedance-based method is increasingly being adopted within industry for small‑signal stability assessments. Notably, TenneT and other European TSOs are requesting impedance-based studies over a wide frequency range (e.g., 10 Hz–2500 Hz), alongside EMT-based studies [ 16 , 14 ] . Although now widely applied to grid-connected converters, the impedance-based approach originates from earlier work on dc–dc power converters. Middlebrook first introduced the method in 1976, demonstrating that system stability could be ensured by keeping the minor loop gain defined as the ratio of the filter impedance to the converter input impedance within the unit circle of the complex plane [ 13 ] . Subsequently, this concept was extended to distributed power systems, where the minor loop gain was required to avoid a predefined forbidden region in the complex plane [ 24 , 25 ] . Building on this foundation, further work introduced new impedance specifications for load impedance and developed updated forbidden regions [ 9 , 8 ] . The resulting design constraint required the load impedance to remain within a prescribed range to ensure small-signal stability and adequate decoupling between subsystems. However, because the forbidden region is based on a fixed phase margin, the criterion implicitly assumes that any new load that satisfies the stability margins with the fixed source will not affect the overall system stability. This is a conservative design, as newly introduced impedances can create additional resonance frequencies that impact the margins of existing loads. Thus, the stability margin criteria defined do not dynamically update when new loads are added, limiting the method’s applicability in converter-based systems. In [ 10 ] , it is proposed to specify impedance profiles even when there are open-loop right-half-plane (RHP) poles by determining the number of open-loop RHP poles and the number of encirclements. While the approach enables stability assessment in the presence of open‑loop RHP poles; it only determines stability through Nyquist encirclements and therefore provides no quantitative measure of stability margin, and secondly, it does not evaluate how the integration of a new converter system impacts the existing converter stability margins. Furthermore, numerical methods are required to determine the number of RHP in the loop gain, making the approach highly undesirable in practice [ 23 ] . Moreover, the test system consists of only two converters operating in parallel, which does not reflect a real OWPP scenario composed of multiple strings with numerous converters and an inter-array cable network. This paper proposes a generalized impedance-based stability margin analysis method for interconnected power park module (PPM) clusters. The method enables impedance specification for a newly connected PPM such that the existing PPM maintains the prescribed stability margins and consequently stable interoperability. The approach is validated using vendor-based EMT project models and frequency-domain models. In addition, the method quantifies the impact of the new connection on the stability margins of the existing PPM. Furthermore, the paper introduces new Nyquist-based stability regions that replace conservative forbidden regions and enable the assessment of margin compliance and headroom. Unlike prior impedance-based criteria that only ensure no Nyquist encirclement or use fixed forbidden regions, the methodology quantifies the change in stability margins when adding a new PPM and provides a condition to guarantee compliance and stable operation. II Impedance modeling In the impedance-based stability criterion, the impedance response of a grid-connected converter is obtained by partitioning the overall system into two subsystems, as shown in Fig. 1 . The grid-connected converter is modeled as a Norton equivalent with an internal impedance Z_{c}(s) , while the grid is represented by a Thévenin equivalent with impedance Z_{g}(s) . The terminal impedances Z_{c}(s) and Z_{g}(s) are then used to determine small-signal dynamics. Applying Kirchhoff’s circuit laws to the interconnected system in Fig. 1 , a closed-loop feedback representation is obtained, which can be used to determine the system stability [ 4 ] . Based on Fig. 1 , the converter output current is I(s)=\frac{Z_{c}(s)\,I_{c}(s)-V_{g}(s)}{Z_{c}(s)+Z_{g}(s)}. (1) Equation 1 can be rearranged to I(s)=\left[I_{c}(s)-\frac{V_{g}(s)}{Z_{c}(s)}\right]\cdot\frac{1}{1+{\color[rgb]{0,0.6914,0.9414}Z_{g}(s)}/{\color[rgb]{0.4375,0.1875,0.6289}Z_{c}(s)}}. (2) Fig. 1: Small-signal representation of grid-connected converter [ 21 ] . The ratio Z_{g}(s)/Z_{c}(s) constitutes the minor-loop gain L(s) of the negative feedback loop. The system stability can be assessed using the Nyquist plot of L(s)