Mid-infrared temporal ghost imaging via two-photon structured encoding

Ziyu He, Kun Huang, Huijie Ma, Wen Zhang, Jianan Fang, Heping Zeng · 2026

Read Mid-infrared temporal ghost imaging via two-photon structured encoding by Ziyu He, Kun Huang, Huijie Ma, Wen Zhang, Jianan Fang, Heping Zeng (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-22298.txt.

Introduction

He and colleagues build a mid-infrared ghost imaging system that uses two-photon absorption. A coded near-infrared pump stamps a pattern onto a mid-infrared signal at a silicon detector. No extra nonlinear crystals are needed, so coding and sensing happen in one step. The rebuilt wave forms beat the detector speed limit by over forty times. Sensitivity reaches 0.05 picojoules per pulse. Compressed sensing cuts the needed measurements by 80 percent. The system works from 2.5 to 3.8 micrometres at room temperature.

Catalog record

CREATORZiyu He, Kun Huang, Huijie Ma, Wen Zhang, Jianan Fang, Heping Zeng
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36342
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.22298

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Mid-infrared temporal ghost imaging via two-photon structured encoding Ziyu He, Kun Huang, Huijie Ma, Wen Zhang, Jianan Fang, Heping Zeng Abstract Temporal ghost imaging (TGI) enables ultrafast signal reconstruction beyond electronic bandwidth limits. Extending this concept to the mid-infrared (MIR) regime through nonlinear frequency conversion offers new opportunities for high-fidelity temporal detection, but remains constrained by stringent phase-matching condition, limited spectral coverage, and intricate optical alignment. Here, we propose and demonstrate a broadband MIR TGI system based on non-degenerate two-photon absorption. A temporally encoded near-infrared pump transfers structured modulation onto a MIR signal directly at a silicon detector, which facilitates concurrent modulation and detection without external nonlinear crystals. The reconstructed temporal waveforms exceed the detector bandwidth by more than fortyfold, achieve a detection sensitivity of 0.05 pJ/pulse, allow compressed sensing with 80% fewer measurements, and support broadband operation across 2.5-3.8 μ \mu m. This compact, alignment-free, and room-temperature system establishes a practical route for fast and sensitive MIR time-domain analysis, holding great promise for applications in time-resolved molecular spectroscopy, high-precision infrared ranging, and high-speed free-space communication. I Introduction Temporal ghost imaging (TGI) is an emerging technique that reconstructs ultrafast temporal signals through intensity correlations without requiring direct time-resolved detection Faccio2016NP . From the perspective of space-time duality Salem2013AOP , TGI can be viewed as the temporal analogue of spatial ghost imaging, in which information is retrieved through correlations between structured illumination and integrated detection Erkmen2010AOP . This correspondence endows TGI with the inherent features of ghost imaging, including robustness against noise, reduced susceptibility to distortions, and enhanced information security Gatti2004PRL . By correlating random or structured temporal sequences with the integrated outputs of a slow “bucket” detector, TGI effectively overcomes the electronic bandwidth limitation of conventional photodetectors, enabling access to ultrafast temporal structures otherwise undetectable Ryczkowski2016NP . Owing to these advantages, TGI has found applications in long-distance communication Yao2018OL ; Chen2021OL , secure data transmission Jiang2017SR , and quantum information processing Wu2019OL . Early implementations of TGI relied on random fluctuations from chaotic lasers Ryczkowski2016NP ; Wu2020OE , spontaneous parametric downconversion (SPDC) photon pairs Denis2017JO , or thermal light sources Devaux2016JO ; Yao2018OL , typically requiring a reference arm for correlation and thus suffering from limited efficiency and stability. The advent of computational TGI introduced programmable light modulators to generate deterministic encoding sequences, eliminating the reference arm and improving reproducibility Xu2018OE . The adoption of orthogonal encoding bases such as Walsh-Hadamard matrices enabled one to improve reconstruction fidelity, computational efficiency, and noise resilience in comparison with random encoding Devaux2016Optica . Furthermore, enhanced variants including differential Oka2017APL and amplified TGI Ryczkowski2017APLP further boosted signal-to-noise ratio and temporal resolution, while Fourier TGI Wenwen2020OLE provides complementary spectral information. Nevertheless, most demonstrations have remained in the visible and near-infrared (NIR) regimes, where mature modulators and detectors are readily available. Indeed, extending TGI into other spectral regions has been hampered by the lack of high-speed modulators and efficient detectors, particularly in the mid-infrared (MIR, 2-20 \mu m) range. This regime is of great importance, as it encompasses the fundamental vibrational fingerprints of molecules, providing rich spectroscopic information for chemical sensing, environmental monitoring, and biomedical diagnostics Cheng2015Science ; Shi2020NM ; Razeghi2014RPP . To overcome detection challenges, various indirect MIR detection schemes have been explored based on nonlinear wavelength conversion, including optical parametric upconversion Dam2012NP ; Huang2022NC ; Junaid2019Optica ; Barh2019AOP and quantum correlation-based methods Paterova2020SA ; Kviatkovsky2020SA . These approaches have enabled remarkable progress in the spatial domain for MIR single-photon imaging Huang2022NC and hyperspectral imaging Fang2024NC , as well as in the spectral domain for MIR spectroscopy Liu2023NC ; Cai2024SA . In the temporal domain, pioneering studies of MIR TGI employed two-color second-harmonic generation for upconverting MIR fluctuations into the NIR, achieving temporal imaging at 2 \mu m Wu2019Optica . Subsequent demonstrations based on difference-frequency generation (DFG) transferred temporal modulation from the NIR pump to the MIR signal, overcoming the lack of high-speed MIR modulators Wu2024LSA . More recently, preprogrammed upconversion methods have further improved sensitivity and reconstruction fidelity, enabling MIR single-photon TGI at 3.4 \mu m Zhang2025LPR . Despite great advances, the crystal-based nonlinear conversion scheme remains constrained by stringent phase-matching requirements, which impose limited spectral coverage and demand careful optical alignment. Furthermore, the involved modulation and detection are implemented in separate stages, fundamentally restricting compactness and scalable integration. Alternatively, an effective route for sensitive MIR detection can leverage nonlinear carrier dynamics in semiconductors, such as two-photon absorption (TPA) Cirloganu2011OE ; Fishman2011NP and higher-order multiphoton processes Nevet2011OL ; Pearl2008APL . In particular, non-degenerate two-photon absorption (ND-TPA) provides enhanced nonlinear coefficient, and inherently supports broadband MIR operation, enabling modulation transfer and detection without requiring phase matching Sterczewski2023NC ; Fishman2011NP . ND-TPA based detection has been successfully applied to room-temperature MIR sensing Fang2020PRA ; Fix2017APL , video-rate spectral imaging Knez2020LSA ; Knez2022SA ; Potma2021APLP , high-sensitivity single-pixel imaging Ma2025PhotoniX , and high-precision depth-resolved tomography Potma2021Optica ; Potma2021APLP . These advances demonstrate the feasibility of ND-TPA for broadband, compact, and room-temperature MIR detection, underscoring its strong potential as a foundation for extending TGI into the MIR regime. Here, we demonstrate a broadband MIR TGI system enabled by ND-TPA in a silicon photodiode. A 1550 nm pump carrying preprogrammed temporal patterns transfers structured modulation onto the MIR signal directly at the detector. Through the ND-TPA process, the MIR temporal modulation and upconversion detection occur simultaneously within the same device, eliminating the need for external nonlinear crystals and complex optical alignment. This concurrent modulation-detection operation intrinsically enhances system compactness, stability, and scalability, establishing a unified platform for efficient MIR temporal measurement. The scheme achieves temporal reconstructions exceeding the detector bandwidth by more than fortyfold, supports sub-Nyquist compressed sensing with 80% fewer measurements, and reaches a detection sensitivity of 0.05 pJ per pulse. Leveraging the broadband nature of ND-TPA, the system operates across 2.5-3.8 \mu m without the need to adjust system parameters. These results underscore the distinctive advantage of concurrent modulation-detection operation, positioning ND-TPA-enabled MIR TGI as a viable and scalable platform for fast and sensitive MIR temporal analysis over a wide spectral coverage. II Basic principle Figure 1 (a) illustrates the operating principle of the broadband MIR TGI system based on ND-TPA. The system consists of three main parts: pump light modulation, ND-TPA detection, and temporal object reconstruction. The light-source modulation module provides the temporal encoding basis. By leveraging high-performance NIR modulators, preprogrammed temporal patterns are imposed on the NIR pump beam. These patterns interact with the MIR waveform via ND-TPA at the detector surface, acting as a temporal gate and producing an ND-TPA signal that modulates the temporal characteristics of the MIR waveform. This indirect modulation strategy enables high-speed, flexible, and all-optical encoding of MIR temporal information. Specifically, ND-TPA detection forms the core of the system. The TPA process can occur in two regimes: degenerate TPA, where both photons have identical energies ( \omega_{1}=\omega_{2} ), and ND-TPA, where the photons possess different energies ( \omega_{1}\neq\omega_{2} ). ND-TPA typically exhibits a higher nonlinear absorption coefficient due to resonant enhancement, where one photon is closer in energy to a real electronic transition, thereby increasing the effective transition probability Fishman2011NP . In our implementation, the NIR pump and MIR signal are spatially and temporally overlapped at a silicon detector. ND-TPA

Read the complete text