Read Alpha Background in Multi-Grid Neutron Detectors by A. Backis, C.-C. Lai, J.R.M. Annand, K.G. Fissum, G. Zuzel, M. Czubak, K. Livingston (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-22230.txt.
Introduction
Backis and co-authors measure alpha background in multi-grid neutron detectors from actinide impurities in aluminum. Alpha rates from radio-pure aluminum and aluminum/B4C composite grids were measured with a large-area low-background spectrometer. Composite rates run about 280 times higher than radio-pure aluminum, yet 25 micrometer nickel plating cuts the composite rate by about 1170 times. Two prototypes with identical B4C-coated radio-pure normal blades differed only in radial blades. The nickel-plated composite prototype background runs around 20 percent of the radio-pure prototype.
Catalog record
| CREATOR | A. Backis, C.-C. Lai, J.R.M. Annand, K.G. Fissum, G. Zuzel, M. Czubak, K. Livingston |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24546 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.22230
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Alpha Background in Multi-Grid Neutron Detectors A. Backis, C.-C. Lai, J.R.M. Annand, K.G. Fissum, G. Zuzel, M. Czubak, K. Livingston Abstract Alpha emission from actinide impurities in Al is a source of background counting rate in Multi-Grid type detectors of thermal neutrons. The alpha emission rates from samples of radio-purity Al and Al / B 4 C \mathrm{Al/B_{4}C} composite, used in grid construction, were measured on a large-area, low background spectrometer. Although the alpha emission rate from the composite was a factor ∼ 280 \sim 280 higher than radio-pure Al, 25 μ m \mathrm{25\>\mu m} Ni plating of the composite reduced the rate by a factor ∼ 1170 \sim 1170 . Background counting rates in two Multi-Grid prototypes were compared. They used identical configurations of B 4 C \mathrm{B_{4}C} -coated, radio-pure Al normal blades for the grids, but the first employed radio-purity Al for the radial blades, while the second used Ni-plated Al / B 4 C \mathrm{Al/B_{4}C} on the radial blades. The background rate from the second prototype was around 20% of that from the first. 1 Introduction Figure 1: Left: prototype T-REX grid. Each voxel has an internal dimension of 22.5 mm (x) by 24.0 mm (y) by 0.95 mm (z). Right: photograph of the 12-grid T-REX prototype TRP-3, with the outer canister removed to show the multi-grid structure. Alpha emission from trace actinide impurities occurring in Al is a source of background [ 1 ] in gaseous detectors of thermal neutrons, which employ neutron capture on \mathrm{{}^{10}B} , to produce detectable ions. Al is the main structural material in most neutron spectrometers of this type, due to its relatively low neutron scattering cross section. Here alpha background has been investigated for prototypes TRP-1 and TRP-3 of Multi-Grid [ 2 ] columns for the T-REX spectrometer at the European Spallation Source (ESS) [ 3 ] . The Multi-Grids are stacks of grids, each a rectangular lattice of normal and radial Al blades (Fig. 1 ). The grids form the cathodes of a voxelised proportional counter (VPC), with wires strung through the centres of each grid voxel providing the anodes. The normal blades are coated with \mathrm{{}^{10}B} -enriched \mathrm{B_{4}C} , and neutron capture in the \mathrm{B_{4}C} film produces \mathrm{{}^{4}He} and \mathrm{{}^{7}Li} ions, one of which escapes into the VPC gas (e.g. Ar-CO2) giving a detectable signal. Al is the main structural material for the grids and the actinide impurities will generally be the long-lifetime \mathrm{{}^{238}U} and \mathrm{{}^{232}Th} isotopes and their daughters. The alpha emission spectra span energies up to \sim 9 MeV, as opposed to \mathrm{\sim 1.4\penalty\ MeV} for post-neutron-capture ions, so this background cannot be rejected by pulse height (PH) discrimination. Radio-purity Al (RP-Al) is employed on the normal MG blades to minimise actinide background. The \mathrm{B_{4}C} coating of 1-2 um allows the ions from neutron capture to escape into the chamber gas, but is too thin to stop most actinide alphas. Both prototypes employ this pattern of normal blades. The radial blades of prototype TRP-1 are uncoated RP-Al, while prototype TRP-3 has radial blades of Ni-plated \mathrm{Al/B_{4}C} composite. The composite provides internal shielding against neutron multiple scattering inside the spectrometer, while the Ni plating has been added to suppress alpha emission, as was observed in Ref. [ 1 ] . Measurements of alpha emission rates from five samples of MG blade material are presented in Sec. 2 and simulations of the alpha stopping power of Ni plating described in Sec. 3 . Sec. 4 reports on background rate tests performed at ESS, and conclusions are summarised in Sec. 5 . 2 Alpha activity measurements Figure 2: Open tray of the large-surface low-background alpha spectrometer. The active area is 43\times 43\>\mathrm{cm^{2}} (the space occupied by four smaller Cu plates on the picture). Samples (sheets) up to 3 mm thick may be accommodated. Alpha emission rates from five samples, as well as no-sample background, were measured using an XIA UltraLow-1800 low background alpha spectrometer (LBAS) [ 4 , 5 ] . The LBAS is an ionisation drift chamber using continuously-flowed argon as the counting gas. It can measure sample sheets, up to an area of 43\times 43\>\mathrm{cm^{2}} and thickness 3 mm. In order to minimise background counting rates the sample tray is covered with Oxygen-Free High Thermal Conductivity (OFHC) copper with etched and electro-polished surfaces. Fig. 2 shows the open tray with four smaller Cu plates covering the active area of the detector. Five sample sheets were tested: 1. Al-1 0.5 mm radio-purity aluminium (RP-Al). 2. Al-1A 0.5 mm RP-Al, sample 1 after cleaning. 3. Al-2 0.5 mm RP-Al. 4. BA: 1.0 mm \mathrm{Al/B_{4}C} composite, 31% \mathrm{B_{4}C} by weight 5. NiP-BA: 1.0 mm \mathrm{Al/B_{4}C} composite, electroless plated [ 6 ] with a nominal \mathrm{25\>\mu m} of Ni-P alloy (NiP), approximately 9% P by weight. Energy spectra from alpha emission were measured from detector threshold at 1.5 MeV up to 10.0 MeV. Background was accumulated for 110 days, while sample-in times were shorter, dependent on the alpha rate. Background-subtracted pulse height spectra obtained for four of the samples are shown in Fig. 3 . The y-scales have been normalised to give the alpha counting rate per day for a surface area of \mathrm{1\>m^{2}} and an energy bin width of 250 keV. Figure 3: Background-subtracted alpha pulse height spectra from sample sheets Al-1, Al-1A, Al-2 and NiP-BA (Table 1 ) Table 1 gives the dimensions, measurement duration and alpha surface emission rate for the five samples and a background measurement with no sample installed, which has been subtracted from the sample-in rates. Alpha rates from the 2 sheets of RP-Al are very similar and Al-1 improved marginally, after cleaning with isopropanol to remove any surface deposits. The other 3 samples (Al-2, BA and NiP-BA) were also cleaned before measurement took place. \mathrm{Al/B_{4}C} composite does not incorporate RP-Al and the rate from sample BA was 284\pm 22 times higher than Al-2 which was RP-Al. However the NiP plating reduced rate by a factor 1170\pm 330 compared to BA, so that the NiP-BA rate was 0.24\pm 0.07 that of Al-2. Sample Size Time Surface alpha rate (cm) (days) ( \mathrm{\alpha/day/m^{2}} ) Al-1 40\times 40\times 0.05 12 320\pm 20 Al-1A 40\times 40\times 0.05 11 280\pm 20 Al-2 40\times 40\times 0.05 13 310\pm 20 BA 30\times 25\times 0.10 0.3 79440\pm 2300 NiP-BA 30\times 25\times 0.15 21 68\pm 19 Background - 110 167\pm 6 Table 1: Parameters of the investigated samples: dimensions, measurement times and measured surface alpha emission rates. The sample emission rates are after background subtraction. 3 Modelling Alpha Emission Geant-4 class G4RadioactiveDecay [ 7 , 8 ] was used to model alpha emission from \mathrm{{}^{238}U} and \mathrm{{}^{232}Th} isotopes and their daughter products, embedded in a \mathrm{400\times 400\times 0.5\>mm^{3}} sheet of Al. G4RadioactiveDecay models the decay sequences using an evaluated nuclear data file [ 9 ] . The sample sheet was located in a detector consisting of a \mathrm{600\times 600\times 50\>mm^{3}} volume of Ar at STP, contained within a thin Al box. Alpha decay chains were started at coordinates chosen randomly within the volume of the sample (excluding any coating layer). Spectra of the energy deposited in the sample and detector are displayed in Fig. 4 . Alpha particle