CERES: A Cryogenic Experiment to Reconstruct Energy Systematics in TeO 2 Bolometers
Enzo Brandani e1,UC,lbl, Yael Zayats UC,lbl, Vladyslav Berest UC,lbl, Tong Zhu UC,lbl, Yury Kolomensky UC,lbl · 2026
Read CERES: A Cryogenic Experiment to Reconstruct Energy Systematics in TeO 2 Bolometers by Enzo Brandani e1,UC,lbl, Yael Zayats UC,lbl, Vladyslav Berest UC,lbl, Tong Zhu UC,lbl, Yury Kolomensky UC,lbl (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-21941.txt.
Introduction
Enzo Brandani and co-authors describe CERES, a cryogenic experiment that measures how energy response varies with position inside tellurium dioxide bolometers. Such detectors hunt rare events like neutrinoless double beta decay, and their power rests on precise energy scale and resolution. Recent work suggests both can shift with where and how energy lands in the crystal, hinting at uncharted systematic effects. CERES is built to measure that position dependence directly, and the paper details its design, current status, and planned upgrades.
Catalog record
| CREATOR | Enzo Brandani e1,UC,lbl, Yael Zayats UC,lbl, Vladyslav Berest UC,lbl, Tong Zhu UC,lbl, Yury Kolomensky UC,lbl |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 14048 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.21941
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
CERES: A Cryogenic Experiment to Reconstruct Energy Systematics in TeO 2 Bolometers Enzo Brandani e1,UC,lbl, Yael Zayats UC,lbl, Vladyslav Berest UC,lbl, Tong Zhu UC,lbl, Yury Kolomensky UC,lbl Abstract Cryogenic calorimetric detectors are a powerful tool in the search for rare events such as neutrinoless double beta decay ( 0 ν β β 0\nu\beta\beta ), due to their excellent energy resolution and low intrinsic background. The performance of these detectors depends critically on a precise understanding of their energy scale and energy resolution. Recent studies suggest that both energy scale and energy resolution may vary depending on the spatial location and topology of energy deposition within the detector, indicating the presence of previously uncharacterized systematic effects. The Cryogenic Experiment to Reconstruct Energy Systematics (CERES) is a dedicated experiment designed to directly measure the position dependence of calorimetric response in Tellurium Dioxide (TeO 2 ) crystals. This paper details the experimental design, current status, and future upgrade plans for CERES. Keywords Neutrinoless double beta decay, Crystal bolometry, Low-temperature calorimeters 1 1 1 e-mail: [email protected] 1 Motivation With precise energy resolution and low intrinsic background, low-temperature crystal calorimetry (bolometry) has proven to be a robust tool for probing physics beyond the Standard Model. These detectors are highly reproducible and scale well for large detector arrays, as evidenced in neutrinoless double beta decay ( 0\nu\beta\beta ) searches such as CUORE 1 ; 2 and its upgrade, CUPID 5 . CUORE and CUPID are instrumented with the Neutron-Transmutation-Doped Germanium (NTD) 12 sensors, which are sensitive to thermal phonons. Their bolometric response has long been considered position-independent. The lack of position-dependent information, however, could be a significant disadvantage of these detectors. One of the most significant sources of background for these rare nuclear event searches is degraded alpha particles from radioactive contamination of materials in the detector volume. Given the low penetration depth of these alphas ( \sim 10 \mu m), these events are usually confined to the surface of the detectors 14 . While CUPID will eliminate the alpha backgrounds by means of particle identification through the simultaneous measurement of heat and light emission in the scintillating Li 2 MoO 4 crystals 5 , surface \beta events remain a significant background. Thus, defining a fiducial volume of the crystal that separates bulk signal events from these surface background events could significantly reduce the overall background. Moreover, topological identification of the remaining multi-site \gamma events 9 could lead to the completely background-free search for 0\nu\beta\beta decay 8 . At the level of precision of the previous experiments, the NTD bolometers have been assumed insensitive to event topology due to their relatively slow response time, as they are sensitive to thermal, as opposed to ballistic phonons. With fast sensors, such as metallic magnetic calorimeters as used in AMORE-II, a position-dependent effect on the detector response has already been observed 15 . Additionally, a recent study of multi-crystal events in CUORE observed a small, sub-KeV effect on both the energy resolution and energy scale, suggesting there could be a measurable, albeit small, effect on the detector response due to the event topology 17 ; 3 . Understanding these effects in detail could improve the energy resolution of the CUORE and CUPID detectors, but also lead to the development of the position and topological reconstruction in the macro-calorimeters. To these ends, we present the concept and design for a novel multisensor bolometer experiment, (a) A 2‑D cartoon cross‑section of a 1‑D crystal depicting the CERES conceptual procedure. The blue‑bordered rectangle represents the crystal; the black squares are the thermal sensors (NTD, TES, etc.); the purple squiggles are the incident radiation at a discrete location x_{N} along the crystal surface. (b) CAD assembly of the CERES jig, including the base, the PTFE corner pieces, the fastening towers, the harp, a dummy 1D crystal, and optical fibers arranged as they were for commissioning. (c) Photo of the CERES jig with a 1D crystal mounted to the experimental plate of the cryostat. Three optical fibers, secured with copper tape to the harp, point at the crystal surface. They are labeled OF1-3 with colors and line styles corresponding to later plots. Additionally, both NTDs are circled and labeled in black. Figure 1 : Overview of the CERES setup: (a) conceptual cartoon, (b) CAD model of the jig, and (c) photograph of the assembled jig. CERES, with the aim of measuring and characterizing these position and topological effects in the energy systematics of TeO 2 crystals. 2 Concept and Design The main goal of CERES is threefold: to measure, quantify, and parameterize the position dependence of the energy reconstruction in TeO 2 crystals. In designing the experiment, we target three observables: timing, amplitude, and pulse shape. We reduced the effective dimensionality of the crystals to perform one- and two-dimensional scans over their surfaces. Thus, we use “strip” wafers that are 5 cm \times 3 mm \times 3 mm, with each pair of long faces oriented normal to [001] and [110], and “slab” wafers that are 5 cm \times 5 cm \times 3 mm, with the largest faces oriented normal to [110]. CERES uses a custom-built copper housing that allows for precise deposition of optical light at predefined positions on the surface of the crystal. The radiation acts as a point-like energy source, exciting phonons that stimulate an electric pulse in the bolometric sensors placed on the ends of the crystal surface. Currently, we opt for optical light instead of traditional silicon heaters used for calibration in similar bolometric experiments in order to produce the phonon spectrum similar to ionizing radiation and to isolate position-dependent effects inherent to the device itself, including the crystal, thermal links, and sensors. For devices of this scale, the heaters would contribute non-negligibly to the overall heat capacity of the system. To enhance phonon collection, the sensors are placed closer to the site of energy deposition than the PTFE weak thermal links. CERES is primarily designed for the use of NTD sensors and Transition Edge Sensors (TES) 13 to convert the phonon signals to electric pulses. One can then use the timing of the pulses to inform position reconstruction. Given the size of our crystals and the speed of sound in TeO 2 , we expect to see timing differences in the pulses on the order of 10 \mu s. The amplitude can be used to reconstruct the relative energy sharing between sensors, which may also be position dependent considering effects due to both sensor and thermal link distance relative to energy deposition. In the current design, we use a 255 nm UV LED as the radiation source with an energy above the TeO 2 band gap so as to excite electron-hole pairs. The LED light is produced at room temperature and coupled to a single-ended optical fiber routed through the cryostat and fastened to copper pillars at each stage to ensure proper thermalization before the light is deposited onto the crystal surface. One challenging aspect of this experimental design is optimizing the position scans. Moving the LED source with traditional motors is infeasible at the required temperatures due to the high heat load, and while there are commercial motors rated for cryogenic use, the price encourages