Velocity-Controlled Directional Readout of Single Photons
Mohamed Hatifi · 2026
Read Velocity-Controlled Directional Readout of Single Photons by Mohamed Hatifi (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-21206.txt.
Introduction
Mohamed Hatifi shows that steady motion changes how a moving Glauber detector reads single photons. Motion shifts the options by Doppler effect in the detector frame, and a finite bandwidth turns travel direction into a detection bias without decohering the photon. Near one Doppler branch, readout moves from phase-sensitive to direction-sensitive, with a boost from the quality factor at onset. Finite-time integration adds Doppler-beat visibility loss, which separates passive covariance from real measurement change.
Catalog record
| CREATOR | Mohamed Hatifi |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 25240 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.21206
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Velocity-Controlled Directional Readout of Single Photons Mohamed Hatifi Abstract Photodetection is usually treated in the frame in which the detector is at rest relative to the optical apparatus. We show that uniform motion of an electric Glauber detector changes the single-click POVM realized on two counterpropagating single-photon modes. Motion Doppler-shifts the alternatives in the detector frame; finite bandwidth then converts propagation direction into a detection bias without decohering the photon. For a Lorentzian response near one Doppler branch, the readout crosses from phase-sensitive to direction-sensitive with a quality-factor-enhanced onset. Finite-time integration adds Doppler-beat visibility loss, separating passive covariance from measurement change. Introduction.— Photodetection is the operational step through which an optical quantum state becomes a measurement record. In the standard Glauber formulation, the detector is effectively at rest with respect to the optical apparatus, and an electric-dipole response probes the positive-frequency electric field through a normally ordered correlation function Glauber 1963 ; Kelley and Kleiner 1964 ; Mandel and Wolf 1995 ; Loudon 2000 . This familiar setting masks a simple relativistic question: if the detector moves relative to the optical modes, what field amplitude does it measure? The underlying relativistic transformations are standard. Electric and magnetic fields mix under Lorentz transformations, and counterpropagating waves are Doppler shifted in opposite directions in the detector frame Jackson 2009 . Related issues arise in relativistic quantum information, moving-detector models, and generalized photodetection schemes with electric and magnetic response channels Birrell and Davies 1982 ; Dragan et al. 2013 ; Hawton 2013 ; Tanimura 2014 ; Hatifi and Stout 2026 . These works establish the importance of the detector frame and the covariance of field descriptions. What remains less explicit is the corresponding measurement-theoretic statement: for a fixed laboratory single-photon state, changing the detector velocity changes the positive-operator-valued measure (POVM) implemented by a realistic detector with finite spectral response Davies and Lewis 1970 ; Polo-Gómez et al. 2022 . The distinction is operational rather than merely descriptive: a passive Lorentz transformation of the complete experiment cannot change physical probabilities. By contrast, changing the detector velocity relative to a fixed laboratory state changes the rest-frame field sampled by the detector. In the broadband limit, this mainly produces a weak, kinematic electric–magnetic admixture. For a spectrally selective detector, however, the two propagation alternatives sample different points of the rest-frame response function Clerk et al. 2010 ; Van Enk 2017 ; Propp and Van Enk 2019 . Motion can therefore make a detection event direction-selective even when the incident single-photon state remains coherent. Here, we show that a moving electric Glauber detector realizes a velocity-dependent, frequency-selective photodetection POVM for a counterpropagating single photon. The detector velocity fixes both the relative weights of the two propagation alternatives and the proper-time Doppler beat between them. We derive the resulting visibility–bias relation for the instantaneous detection probability and show that, when a Lorentzian detector is operated near one Doppler branch, the crossover from phase-sensitive to direction-sensitive readout is set by the Doppler splitting in units of the detector linewidth. Thus, detector motion acquires a direct measurement-theoretic meaning: it changes the measurement axis selected by the detector on the single-photon propagation qubit. The predicted signatures are a Doppler beat in the detection record, a controllable visibility–bias tradeoff, and a crossover from interference-sensitive to which-way readout set by detector bandwidth rather than by a relativistic velocity scale alone. The most accessible tests are likely in microwave, circuit-QED, optomechanical, or time-modulated photonic platforms, where narrowband detection and synthetic Doppler shifts can replace literal high-speed optical motion Kippenberg and Vahala 2008 ; Romero et al. 2009 ; Fang et al. 2012 ; Sathyamoorthy et al. 2016 ; Sounas and Alù 2017 ; Besse et al. 2018 ; Yuan et al. 2018 ; Harwood et al. 2025a . More broadly, the result shows that detector motion can select the quantum observable realized by photodetection, separating passive Lorentz covariance from a physical change of measurement. Rest-frame Glauber detection.— Consider a detector moving at constant velocity v=\beta c along the x axis of the laboratory frame. We choose the origin such that the detector crosses x=0 at t=0 . Its proper time \tau and laboratory coordinates are then related by t=\gamma\tau,\qquad x=\gamma\beta c\,\tau,\qquad\gamma=(1-\beta^{2})^{-1/2}. (1) We take the detector to be purely electric in its own rest frame. The lowest-order instantaneous count rate, per unit detector proper time, is governed by the positive-frequency electric field evaluated on the detector worldline Glauber 1963 ; Kelley and Kleiner 1964 , R(\tau)\propto\left\langle\widehat{E}^{\prime(-)}_{y}(\tau)\widehat{E}^{\prime(+)}_{y}(\tau)\right\rangle, (2) where the prime denotes the detector rest frame and the positive-frequency part is defined with respect to the detector proper time. For transverse laboratory fields E_{y} and F_{z}=cB_{z} , the Lorentz transformation to the detector frame gives Jackson 2009 \widehat{E}^{\prime(+)}_{y}=\gamma\left(\widehat{E}^{(+)}_{y}-\beta\widehat{F}^{(+)}_{z}\right). (3) For the inertial monochromatic modes considered below, the Doppler-shifted frequencies remain positive for |\beta|<1 , so Eq. ( 3 ) is equivalent to transforming the full field and then retaining its positive-frequency part along the worldline. Thus, a detector that is purely electric in its own frame is described in the laboratory frame by a velocity-fixed electric–magnetic detection amplitude Durnin et al. 1981 ; Tanimura 2014 ; Hatifi and Stout 2026 . We now apply this rest-frame detection rule to two counterpropagating laboratory modes Akhlaghi et al. 2015 ; Hatifi 2026 with the same frequency \omega=ck , polarization along y , and field normalization \mathcal{E} . Their positive-frequency electric field and rescaled magnetic field are \displaystyle\widehat{E}^{(+)}_{y}(x,t) \displaystyle=\mathcal{E}\left(\hat{a}_{+}e^{ikx-i\omega t}+\hat{a}_{-}e^{-ikx-i\omega t}\right), (4) \displaystyle\widehat{F}^{(+)}_{z}(x,t) \displaystyle=\mathcal{E}\left(\hat{a}_{+}e^{ikx-i\omega t}-\hat{a}_{-}e^{-ikx-i\omega t}\right), (5) where + and - label propagation along +x and -x , respectively. The opposite signs in Eq. ( 5 ) express the reversal of the magnetic field under reversal of the propagation direction. Evaluated on the detector worldline, the two phases are kx-\omega t=-\gamma(1-\beta)\omega\tau,\qquad-kx-\omega t=-\gamma(1+\beta)\omega\tau. Figure 1: Moving-detector geometry. A detector moving along +x with velocity v=\beta c probes two counterpropagating single-photon modes of the same laboratory frequency \omega . The right-propagating blue mode is annihilated by \hat{a}_{+} and carries wave vector +\mathbf{k} , while the left-propagating red mode is annihilated by \hat{a}_{-} and carries wave vector -\mathbf{k} . Although the detector is purely electric in its rest frame, its laboratory-frame response mixes electric and magnetic amplitudes and samples the two modes at the Doppler-shifted frequencies \Omega_{\pm}=\gamma(1\mp\beta)\omega . This is the origin of the velocity-dependent photodetection POVM derived below. The detector therefore sees the two propagation alternatives at the Doppler-shifted frequencies \Omega_{+}=\gamma(1-\beta)\omega,\qquad\Omega_{-}=\gamma(1+\beta)\omega, (6) with splitting \Delta\Omega=\Omega_{-}-\Omega_{+}=2\gamma\beta\omega . Combining Eqs. ( 3 )–( 5 ), the rest-frame electric field sampled by a broadband moving detector is \widehat{E}^{\prime(+)}_{y}(\tau)=\gamma\mathcal{E}\left[(1-\beta)\hat{a}_{+}e^{-i\Omega_{+}\tau}+(1+\beta)\hat{a}_{-}e^{-i\Omega_{-}\tau}\right]. (7) Equation ( 7 ) displays the two velocity-dependent structures inherited by the measurement operator. The amplitudes 1\mp\beta encode Lorentz-induced electric–magnetic mixing, while the frequencies \Omega_{\pm} encode the Doppler splitting that a finite-bandwidth or finite-time detector can convert into operational distinguishability. Velocity-dependent single-photon POVM.— We now include the detector’s finite spectral response in its rest frame. For a linear stationary detector, the response acts as a convolution in proper time; for the monochromatic components considered here, this reduces to multiplication by a complex susceptibility \chi(\Omega) evaluated at the corresponding detector-frame frequency Clerk et al. 2010 ; Van Enk 2017 ; Young et al. 2018 ; Propp and Van Enk 2019 . The detected positive-frequency amplitude