Quantized Machine Learning Models for Medical Imaging in Low-Resource Healthcare Settings

Sumanth Meenan Kanneti, Aryan Shah · 2026

Read Quantized Machine Learning Models for Medical Imaging in Low-Resource Healthcare Settings by Sumanth Meenan Kanneti, Aryan Shah (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-19207.txt.

Introduction

Sumanth Meenan Kanneti and Aryan Shah present a shrinking framework for brain tumour MRI sorting, aimed at low-resource clinics. It mixes quantization-aware training, teaching a compact student, and Float16 shrinking on a light backbone. Full checks are given for this flow, trained by transfer learning and shrunk via TensorFlow Lite, while other plans await future checks. The shrunk model reaches 82.37 percent correct against an 82.20 percent base mark, shrinking from 35.34 MB to 5.76 MB, a 6.14-times shrink with no real score loss, holding across all four groups.

Catalog record

CREATORSumanth Meenan Kanneti, Aryan Shah
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35079
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2605.19207

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Quantized Machine Learning Models for Medical Imaging in Low-Resource Healthcare Settings Thanks: Identify applicable funding agency here. If none, delete this. Sumanth Meenan Kanneti, Aryan Shah Abstract Deep learning models have shown strong performance in medical image analysis, but deploying them in low-resource clinical environments remains difficult due to computational, memory, and power constraints. This paper presents a multi-strategy compression framework for brain tumor classification from MRI, encompassing quantization-aware training, knowledge distillation from a DenseNet-101 teacher to a compact DenseNet-32 student with low-bit post-training quantization, and Float16 post-training quantization on a lightweight MobileNetV2 backbone. Using a multi-class brain tumor MRI dataset containing glioma, meningioma, pituitary tumors, and healthy controls, we provide full experimental validation of the MobileNetV2-based pipeline, training the classifier through a three-stage transfer learning process and applying Float16 quantization via TensorFlow Lite. The DenseNet-based distillation and quantization-aware training strategies are described as complementary compression approaches within the framework, with their complete empirical evaluation reserved for future work. Experimental results on the MobileNetV2 pipeline show that the quantized model achieves 82.37% validation accuracy compared to the 82.20% full-precision baseline, reducing model size from 35.34 MB to 5.76 MB, a 6.14× × \times compression ratio with no meaningful accuracy loss. Per-class evaluation confirms that quantization preserves diagnostic performance uniformly across all four tumor categories. These findings demonstrate that lightweight quantized models can deliver clinically viable brain tumor screening in resource-constrained healthcare settings. University of Southern California Los Angeles, USA [email protected] I Introduction Deep learning has rapidly transformed medical image analysis by enabling automated detection and classification of complex pathological patterns with accuracy approaching that of expert clinicians. Convolutional Neural Networks (CNNs), in particular, have demonstrated strong performance across a wide range of radiological tasks, including tumor detection, organ segmentation, and disease staging from MRI, CT, and X-ray images. In neuro-oncology, MRI-based brain tumor classification has benefited significantly from deep architectures such as DenseNet, ResNet, and MobileNet, which leverage deep feature reuse, residual connections, and efficient inverted bottleneck designs to capture subtle structural variations across tumor types. These advances promise faster screening, reduced diagnostic burden, and improved clinical decision support. However, most high-performing deep models are computationally intensive, requiring GPUs, large memory footprints, and stable power supply, assumptions that do not hold in many real-world healthcare environments. Rural clinics, mobile diagnostic units, and under-resourced hospitals often operate with limited hardware, low-power CPUs, or edge devices where deploying full-precision deep networks is impractical. As a result, there is a growing gap between algorithmic capability and deployable clinical utility. Bridging this gap requires not only accurate models but also efficient ones, models that preserve diagnostic performance while operating under strict compute and memory constraints. Model compression and numerical efficiency techniques have therefore become central to the emerging field of edge medical AI. Among these, quantization, the reduction of numerical precision of model weights and activations, has emerged as one of the most practical and hardware-compatible approaches for accelerating inference and reducing model size. By converting floating-point parameters (typically 32-bit) into lower-bit representations such as Float16 or INT8, quantization can substantially decrease memory usage and increase throughput on commodity processors and specialized accelerators. Two major paradigms exist: post-training quantization (PTQ), which compresses a trained model after convergence, and quantization-aware training (QAT), which simulates low-precision arithmetic during training so that the network learns robustness to quantization noise. While PTQ is simpler to apply, QAT often yields better accuracy retention, especially for deeper architectures. Complementing numerical compression, structural compression methods such as knowledge distillation train smaller ”student” networks to mimic the outputs of larger ”teacher” models, transferring representational power while reducing architectural complexity. Together, quantization and distillation form a powerful toolkit for designing lightweight yet accurate models suitable for edge deployment. Despite substantial progress in efficient deep learning, relatively few studies systematically evaluate these strategies in the context of multi-class brain tumor MRI classification with explicit deployment goals for low-resource healthcare settings. In this work, we present a multi-strategy compression framework for brain tumor image classification that encompasses Float16 post-training quantization, quantization-aware training, and knowledge distillation to produce deployment-ready models for low-resource environments. Using a curated multi-class MRI dataset containing glioma, meningioma, pituitary tumors, and non-tumor cases, we provide full experimental validation of a MobileNetV2-based pipeline, training the classifier through a three-stage transfer learning process, frozen-backbone head training, full-model fine-tuning, and extended low-learning-rate refinement, followed by Float16 post-training quantization via TensorFlow Lite. As complementary compression strategies within the framework, we additionally describe a quantization-aware training approach using the TensorFlow Model Optimization Toolkit with representative dataset calibration for INT8 conversion, and a knowledge distillation pipeline where a compact DenseNet-32 student model learns from a higher-capacity DenseNet-101 teacher, followed by low-bit post-training quantization. Complete empirical evaluation of these two complementary strategies is reserved for future work. Across all strategies, we evaluate not only classification accuracy but also model size and deployment feasibility, emphasizing practical edge performance rather than accuracy alone. The contributions of this paper are threefold. First, we design a multi-strategy compression framework that integrates post-training quantization, quantization-aware training, and distillation-based compression for brain tumor MRI classification, and describe the methodology for each approach. Second, we experimentally demonstrate that Float16 post-training quantization on a MobileNetV2 backbone achieves a 6.14 \times reduction in model size with no meaningful accuracy loss, producing a 5.76 MB model suitable for CPU-only and low-power edge devices. Third, we show through per-class evaluation that the quantization process preserves diagnostic performance uniformly across all tumor categories, confirming the clinical viability of the compressed model. Beyond algorithmic results, our study is motivated by accessibility: enabling reliable AI-assisted diagnostics in environments with limited computational infrastructure. By designing and evaluating quantized classifiers under deployment-oriented constraints, this work contributes practical evidence and methodology toward democratizing medical imaging AI and advancing edge-ready healthcare machine learning systems. II Methods and Data II-A Problem Setting and Task Definition This study focuses on efficient deep learning methods for multi-class brain tumor classification from magnetic resonance imaging (MRI) scans under low-resource deployment constraints. The primary objective is to design, train, compress, and evaluate convolutional neural network models that maintain high diagnostic accuracy while significantly reducing model size and inference cost. We frame the problem as a supervised multi-class image classification task with four output categories: glioma tumor, meningioma tumor, pituitary tumor, and no-tumor (healthy control). Given an input MRI slice image, the model predicts the tumor class label. Unlike conventional medical imaging model development, which optimizes primarily for predictive performance, our methodology explicitly incorporates deployment efficiency constraints . We therefore evaluate not only classification accuracy but also model footprint, numerical precision, and inference efficiency. To support this objective, we present a multi-strategy compression framework encompassing three approaches: (1) Float16 post-training quantization on a MobileNetV2 backbone, which serves as the primary experimentally validated pipeline, (2) quantization-aware training (QAT) with full-integer deployment conversion using representative dataset calibration, and (3) knowledge distillation from a high-capacity DenseNet-101 teacher model to a compact DenseNet-32 student model followed by low-bit post-training quantization. A full-precision MobileNetV2 baseline trained through a three-stage transfer learning process is first established to provide an upper-bound performance reference. The QAT and DenseNet distillation strategies are described as complementary compression approaches within the framework; their complete empirical evaluation is reserved for future work. II-B Dataset Description

Read the complete text