Read Environmental Stabilization of Perfect-Crystal Neutron Interferometry Using a Large Vacuum Chamber with Cryogenic Sample Access Journal: Nuclear Instruments and Methods by R. Valdillez, D. G. Cory, R. W. Haun, B. Heacock, C. Heikes, S. F. Hoogerheide, M. G. Huber*, T. Mineeva, J. Paster, D. Sarenac, D. A. Pushin, A. R. Young (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-18874.txt.
Introduction
Robert Valdillez and eleven colleagues describe a large vacuum chamber built to steady perfect-crystal neutron interferometry. The technique is easily thrown off by temperature and pressure shifts across its crystal. Installed at the NIST neutron facility, the chamber shields the instrument from local drift and admits cryogenically cooled samples. The team reports the first interferometer measurement of such a cooled sample, tracking contrast in a nickel-copper alloy from 4 kelvin to room temperature and opening the way to superconductivity studies.
Catalog record
| CREATOR | R. Valdillez, D. G. Cory, R. W. Haun, B. Heacock, C. Heikes, S. F. Hoogerheide, M. G. Huber*, T. Mineeva, J. Paster, D. Sarenac, D. A. Pushin, A. R. Young |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 47340 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.18874
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Environmental Stabilization of Perfect-Crystal Neutron Interferometry Using a Large Vacuum Chamber with Cryogenic Sample Access Journal: Nuclear Instruments and Methods R. Valdillez, D. G. Cory, R. W. Haun, B. Heacock, C. Heikes, S. F. Hoogerheide, M. G. Huber*, T. Mineeva, J. Paster, D. Sarenac, D. A. Pushin, A. R. Young Abstract Perfect-crystal neutron interferometry has been a useful tool in measuring nuclear-interactions, probing fundamental physics, and exploring quantum phenomenon. Historically, neutron interferometry experiments have been carried out at room temperature and standard atmospheric pressure. However, neutron interferometry is sensitive to changes in the local environment, especially thermal gradients across the crystal, resulting in phase drifts and systematic uncertainty. A need for measurements performed in different sample environments compound these issues. Fortunately, the use of a vacuum chamber has been shown to be an effective method of environmental isolation for perfect-crystal neutron interferometers. A large volume, highly versatile vacuum chamber has been installed at the Neutron Interferometry and Optics Facility at the NIST Center for Neutron Research to isolate interferometry from local temperature and pressure deviations as well as allowing for the introduction of cryogenically cooled samples. The prospect of incorporating a cryostat within a neutron interferometer opens up new areas of investigation, such as superconductivity. In addition to describing the vacuum chamber, we report on the first measurement of a cryogenic-cooled sample by a neutron interferometer. For this demonstration contrast was measured with a Ni 60 Cu 40 \mathrm{Ni}_{60}\mathrm{Cu}_{40} sample between 4 K 4\text{\,}\mathrm{K} to 300 K 300\text{\,}\mathrm{K} . 1 Introduction Neutron interferometry (NI), utilizing a perfect silicon crystal, was first demonstrated in 1974 [ 28 ] . It has since proved to be a useful tool for studying a range of physics problems [ 29 ] . These include precision measurements of coherent and incoherent scattering lengths [ 16 , 13 , 32 ] , phase contrast imaging [ 25 ] , gravitationally induced quantum interference effects [ 19 , 14 , 24 ] , dark energy/5 fifth force force searches [ 18 ] , and studies of neutron orbital angular momentum [ 7 , 31 ] . One area in which NI has found only limited use is in materials research. This is despite there are many neutron scattering instruments such as small-angle neutron scattering (SANS), triple-axis diffractometers, and reflectometers [ 17 , 22 ] that are tailored for materials research. The inherent challenges facing the use of neutron interferometry for material science are that NI operates with lower statistics than widely-used neutron scattering instruments and it has a greater sensitivity to environmental noise. However, the NIST Center for Neutron Research (NCNR) is aiming towards a broader use for NI through the development of vacuum isolation and decoherence free subspace techniques from quantum information science. The capabilities, newly demonstrated in this paper, to cool and control a sample temperature over the range from 4\text{\,}\mathrm{K} to 300\text{\,}\mathrm{K} opens a variety of new research avenues that have been previously unavailable, particularly in condensed matter physics and materials science. The capabilities and characteristics of a large volume vacuum chamber and cryostat for NI are discussed below. 2 Interferometry 2.1 Closed Loop Interferometry Perfect silicon crystal neutron interferometry is analogous to Mach-Zehnder (MZ) interferometry for light. Instead of using full and half mirrors to split and recombine the incident radiation beam, perfect-crystal neutron interferometry uses Bragg diffraction to coherently split the wave into spatially separate paths. A neutron interferometer consists of a single perfect silicon crystal ingot machined so that there are two or more crystal blades extruding from a large common base. The common base provides stability and ensures that the crystal blade’s atomic planes are aligned relative to one another. Neutrons are Bragg diffracted in the first crystal blade, acting like a beam splitter. Subsequent blades are used to interfere the two paths as the neutron exits the interferometer. A skew-symmetric perfect-crystal neutron interferometer, where the diffracting blades are not all equally spaced, is shown in Fig. 1 . Figure 1 : (LEFT) A photo of a skew-symmetric perfect-crystal silicon neutron interferometer. (RIGHT) A perfect-crystal neutron interferometer separates a neutron along two paths which interfere before exiting the interferometer. Changes in the relative phase shift between Path I and II modulate the intensities ( I_{O} and I_{H} ) measured by the detectors. A sample called a phase flag is used to controllably vary the phase. Neutrons exit the last blade in two directions, one in the same direction as the incident beam (O-beam) and one in the diffracted direction (H-beam). Detection of the neutrons after exiting the interferometer is done using 3 He proportional counters with nearly 100\text{\,}\% detection efficiency. The intensity of the O- and H-beams, \begin{split}I_{0}&=c_{0}+c_{1}\cos(\Delta\phi)\\ I_{H}&=c_{2}-c_{1}\cos(\Delta\phi),\end{split} (1) are 180\text{\,}\mathrm{\SIUnitSymbolDegree} out of phase, and since there is almost no neutron absorption in silicon, the sum of the O- and H- beam intensities is a constant. In Eqn. 1 , the coefficients c_{0,1,2} are related to the incident neutron beam intensity and initial contrast of the interferometer but are generally treated as fit parameters. The O-beam contrast of \mathcal{C}=c_{1}/c_{0} is regarded as a coarse gauge on the quality. Contrast can also be decreased by overall noise, beam size, sample effects, and other parameters of the overall experiment setup. Large phase drifts, instability, or loss of coherence decreases \mathcal{C} , which for the interferometers at NIST, typically start at greater than 80\text{\,}\% . The parameter \Delta\phi is the relative phase difference between the interferometer paths I and II. A sample placed in path II causes a relative phase shift of \displaystyle\Delta\phi_{\mathrm{nucl}}=-\lambda\cdot N(T)\cdot b_{c}\cdot D\hskip 12.0pt\textnormal{(Nuclear)}\ (2) due to the neutron-nuclei interaction. Here \lambda is the neutron wavelength, N(T) is the atomic density of a sample at temperature T , b_{c} is the scattering length which is an isotope-dependent quantity, and D is the sample thickness. The phase along each path of the interferometer may be varied by rotating a control sample called a phase flag, typically a 2\text{\,}\mathrm{m}\mathrm{m} thick piece of quartz. In addition to the neutron’s interaction with a nucleus, a magnetic field along one path generates a relative phase, \displaystyle\Delta\phi_{\mathrm{mag}}=\pm\frac{\mu_{\textrm{n}}m_{\textrm{n}}\lambda DB_{0}}{2\pi\hbar^{2}}\hskip 12.0pt\textnormal{(Magnetic)}\ (3) where \mu_{\textrm{n}}= -9.649\text{\,}\mathrm{J}\mathrm{/}\mathrm{T} is the magnetic moment of the neutron, m_{\textrm{n}}= 1.675\text{\times}{10}^{-27}\text{\,}\mathrm{k}\mathrm{g} is the neutron mass, and here D is the length of the region with constant magnetic field B_{0} . 2.2 Pendellösung Interferometry Beyond utilizing perfect-silicon crystals to construct a closed-loop, MZ-like interferometer—where the interaction of interest is occurring between the crystal blades—interference effects also occur within the perfect crystals themselves. Known as pendellösung interference, this phenomenon results from the neutron undergoing multiple scattering as it traverses the crystal, a process described by the theory of dynamical diffraction [ 11 ] . While the details will be omitted here, the interference arises from the superposition of the two solutions of the Schrödinger equation, labeled \alpha and \beta , inside the crystal and results in rapidly oscillating intensity profiles like those shown in Fig. 2 . The period of oscillation is given by the ratio of the crystal thickness t over the pendellösung length \Delta_{H} . The pendellösung length is determined by the crystal lattice and for silicon is typically on the order of 50\text{\,}\mathrm{\SIUnitSymbolMicro} . The oscillations shown in Fig. 2 are usually