Non-linear diffusion and inhomogeneity of the magnetic field in single-turn coils: Insights from 3D multiphysics modeling
Hideaki Kobayashi, Yugaku Goyo, Yuto Ishii, Yasuhiro H. Matsuda, Kunio Takekoshi, Akihiko Ikeda · 2026
Read Non-linear diffusion and inhomogeneity of the magnetic field in single-turn coils: Insights from 3D multiphysics modeling by Hideaki Kobayashi, Yugaku Goyo, Yuto Ishii, Yasuhiro H. Matsuda, Kunio Takekoshi, Akihiko Ikeda (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-16659.txt.
Introduction
Kobayashi and colleagues model the single-turn coil, a destructive pulsed magnet that tops 100 tesla for a few microseconds before exploding. Using a full 3D model of the coil, they simulate current, heat, and magnetic field together. The results show strongly nonlinear spread of all three, driven by the skin effect, rapid heating, and coil deformation. That uneven spread explains why the field inside the coil varies so much in time and space.
Catalog record
| CREATOR | Hideaki Kobayashi, Yugaku Goyo, Yuto Ishii, Yasuhiro H. Matsuda, Kunio Takekoshi, Akihiko Ikeda |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 20145 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.16659
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Non-linear diffusion and inhomogeneity of the magnetic field in single-turn coils: Insights from 3D multiphysics modeling Hideaki Kobayashi, Yugaku Goyo, Yuto Ishii, Yasuhiro H. Matsuda, Kunio Takekoshi, Akihiko Ikeda Abstract The single-turn coil method is a destructive pulsed magnet for generating over 100 T with a few μ \mu -second pulse duration, and it inevitably causes the coil to explode. The temporal and spatial distributions of the electric current and magnetic field are highly inhomogeneous, arising from the skin effect, rapid temperature rise, and coil deformation. To grasp the dynamic phenomena in the single-turn coil, we conducted a finite element analysis using multiphysics simulation. We employed finite element method calculations using a fully 3D model of the single-turn coil with broken cylindrical symmetry. The calculated result revealed highly nonlinear diffusion of electric current, temperature, and magnetic fields, which are the sources of the inhomogeneous magnetic fields inside the single-turn coil in time and space. I Introduction The ultrahigh magnetic field region beyond 100 T, extending to 1000 T, is an experimental frontier of science. Recently, novel phase transitions have been discovered in the 1000 T region in such condensed matters as solid O 2 Nomura et al. 2014 ; Nomura et al. 2022 , CdCr 2 O 4 Miyata et al. 2011 ; Gen et al. 2026 , VO 2 Matsuda et al. 2020 ; Matsuda et al. 2026 , FeSi Nakamura et al. 2021 , YbB 12 Terashima et al. 2017 , SmB 6 Nakamura et al. 2022 , LaCoO 3 Ikeda et al. 2016 ; Ikeda et al. 2020 ; Ikeda et al. 2023 , SrCu 2 (BO 3 ) 2 Matsuda et al. 2013 ; Nomura et al. 2023 . These discoveries are made using improved techniques of the single turn coil method and the electro-magnetic flux compression method, and also using the new measurement technique ranging from magneto-optical effects Miyata et al. 2011 , the high-frequency conductivity Kohama et al. 2020 ; Shitaokoshi et al. 2023 ; Peng et al. 2025 , magnetization Takeyama et al. 2012 ; Gen et al. 2023 , magnetostriction Rodriguez et al. 2015 ; Ikeda et al. 2017 , ultrasound Nomura et al. 2021 , dielectric constant Chiu et al. 2025 Modification of the single-turn coil method, such as putting crey on the outside of the single-turn coil Gen et al. 2021 , and putting a slit by removing the center volume of the single turn coil Ishii et al. 2026 are reported. When generating an intense magnetic field above 100 T, the coil is subjected to tensile stress of 4 GPa, leading to the coil’s explosion. This feature makes the research area beyond 100 T an experimental frontier. The explosion is the consequence of the energy density of the magnetic field expressed as E/V=B^{2}/(2\mu_{0}) whose unit is [J/m 3 ], which is equal to [Pa] the pressure. It states that confining a magnetic field of 100 T and 1000 T inevitably requires 4 GPa and 400 GPa, respectively. That pressure is applied to the coil, causing it to explode. It also states that one definitely needs a high pressure to achieve well beyond 100 T and to reach 1000 T, which is realized by the implosion of the liner in the flux compression methods Herlach 1999 ; Nakamura et al. 2018 The aforementioned methods are achieved by overcoming or avoiding the characteristics of the single-turn coil, the short \mu -second pulse, explosion, electromagnetic noise, single-shot nature, and highly inhomogeneous magnetic field in time and space. Recently, notable efforts have been made in the above-100 T region, ranging from new techniques to make the single-turn coil portable Ikeda et al. 2022 . The technique has enabled the x-ray experiment using x-ray free electron laser Ikeda et al. 2025 , which opens a new era for the 100 T science. Single turn coil has been devised experimentally by Herlach Herlach et al. 1971 ; Herlach and McBroom 1973 ; Herlach et al. 1974 , in Tokyo Nakao et al. 1985 ; Takeyama et al. 1988 ; Sakakibara et al. 1990 ; Aruga Katori et al. 1995 , and in Berlin Portugall et al. 1997 ; Puhlmann et al. 1997 . See the reviews Herlach 1968 ; Herlach 1999 . Previously, finite-element methods has been employed to simulate the flux-compression methods Miura and Nakao 1990 ; Nakamura et al. 2014 and the single-turn coil methods Miura and Nakao 1990 ; Ge et al. 2023 ; Ge et al. 2024a ; Ge et al. 2024b ; Ge et al. 2024c ; Ge et al. 2024d ; Ge et al. 2024e ; Ge et al. 2024f ; Ge et al. 2025a ; Ge et al. 2025b . All these studies assume the cylindrical symmetry of the model. However, in considering the inhomogeneity of the single-turn coil, it is crucial to take into account the feed gap (neck part) of the single turn coil. Here, we employed finite element method calculations using a fully 3D model of the single-turn coil with a broken cylindrical symmetry. The calculated result revealed a non-linear diffusion of electric current, temperature, and magnetic fields, which are the source of the inhomogeneous magnetic fields inside the single-turn coil in time and space. II Method Experimentally, we generated a 120 T using the PINK-03 in the University of Electro-Communications, Tokyo, Japan. PINK-03 is an identical system to PINK-02, devised for the x-ray free electron laser experiment in Ref. Ikeda et al. 2025 . Fig. 1 shows the photos of the single turn coils of \phi 3 to \phi 4 mm, the schematic drawing of the electric circuit, the obtained magnetic field waveform, and the photos of the before, on, and after the 120 T generation. Figure 1: (a) The photos of the single turn coils of \phi 3 to \phi 4 mm. (b) The schematic drawing of the electric circuit. (c) The obtained magnetic field waveform. (c) The photos of the before, during, and after the 120 T generation. Figure 2: The finite element model of a single turn coil of the diameter \phi 4 mm. The profiles of the input current and the obtained magnetic fields at the center position of the single-turn coil. The relation between the maximum current and the maximum magnetic field at the center position. The relation between the maximum current and the time to reach the maximum magnetic field at the center position of the single-turn coil. Figure 3: The representative result of the calculation in the 120 T generation using the 750 kA current. The cross-sectional view of the neck part and the top part of the single turn coil at 0.3 \mu s and at 1.5 \mu s, which are generating 50 T (an early stage) and 120 T (the maximum stage), respectively. The single-turn coil of \phi 4 mm is modeled using FUSION360 . The finite element model is using Altair HyperWorks with ??? elements as shown in Fig. 2 . To account for the skin effect, smaller elements are placed in the proximity of the inner surface of the coil. Ansys LS-DYNA Ver. R13.1.1 is used for the multiphysics FEM calculation. A Threadripper PRO 5995WX (64-core CPU) with 512 GB of random access