Single Spatio-Temporal Mode Bright Twin-Beam Source Across the Near- and Mid-Infrared Journal: opticajournal
Gabriel Demontigny, Patrick Cusson, Amauri Perraton-Elorza, Esteban Murillo-Zapata, Eli Martel, Andrei Rasputnyi, Maria Chekhova, Stéphane Virally, Denis Seletskiy · 2026
Read Single Spatio-Temporal Mode Bright Twin-Beam Source Across the Near- and Mid-Infrared Journal: opticajournal by Gabriel Demontigny, Patrick Cusson, Amauri Perraton-Elorza, Esteban Murillo-Zapata, Eli Martel, Andrei Rasputnyi, Maria Chekhova, Stéphane Virally, Denis Seletskiy (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-15385.txt.
Introduction
Gabriel Demontigny and eight others offer a bright, ultrafast entangled twin-beam source spanning near- and mid-infrared bands. Type-0 parametric down-conversion in regularly poled lithium niobate at MHz rates yields a Schmidt number near 1.05, a single spatio-temporal mode, tunable smoothly into a set multimode regime via pump dispersion. The signal at 1.37 microns and idler at 4.0 microns decouple a mid-IR meeting band sharing molecular vibrations from a near-IR detection band, allowing quantum-enhanced sensing.
Catalog record
| CREATOR | Gabriel Demontigny, Patrick Cusson, Amauri Perraton-Elorza, Esteban Murillo-Zapata, Eli Martel, Andrei Rasputnyi, Maria Chekhova, Stéphane Virally, Denis Seletskiy |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 60665 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.15385
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Single Spatio-Temporal Mode Bright Twin-Beam Source Across the Near- and Mid-Infrared Journal: opticajournal Gabriel Demontigny, Patrick Cusson, Amauri Perraton-Elorza, Esteban Murillo-Zapata, Eli Martel, Andrei Rasputnyi, Maria Chekhova, Stéphane Virally, Denis Seletskiy Abstract We introduce an ultrafast, bright, entangled twin-beam source generated by type-0 parametric down-conversion in periodically-poled lithium niobate at MHz repetition rate, with continuously tunable Schmidt number K K set by the pump pulse duration. Photon-number statistics characterization via g ( 2 ) ( 0 ) g^{(2)}(0) and singular-value decomposition of the signal spectral density matrix yield K ≃ 1.05 K\simeq 1.05 and K ≃ 1.03 K\simeq 1.03 , respectively, maintained over multiple orders of magnitude in brightness. Group-delay dispersion of the pump drives a continuous transition from single-mode operation to a controlled multimode regime, consistent with the temporal gain window departing from the inverse phase-matching bandwidth. Strong non-degeneracy of the source (signal at 1.37 µ m 1.37\text{\,}\mathrm{\SIUnitSymbolMicro m} , idler at 4.0 µ m 4.0\text{\,}\mathrm{\SIUnitSymbolMicro m} , ∼ 100 fs \sim$100\text{\,}\mathrm{fs}$ duration) decouples a mid-infrared interaction wavelength, which overlaps with molecular vibrational resonances, from a near-infrared detection band, establishing a practical platform for quantum-enhanced metrology, nonlinear interferometry, and mid-infrared spectroscopic sensing. We show that in the bright few-mode limit, the total entanglement resource is clearly separated between modal and occupational degrees of freedom, and that our source allocates up to 95 to 97 % 9597\text{\,}\mathrm{\%} of that resource to the occupational sector. 1 Introduction and Motivation Nonclassical light sources that are simultaneously bright , ultrafast , and mode-controlled are of great interest for quantum-enhanced metrology, nonlinear interferometry, and spectroscopic sensing. In particular, non-degenerate parametric down-conversion (PDC) produces two-mode squeezed vacuum whose quantum correlations between signal and idler [ 1 ] are advantageous in many applications, including quantum-enhanced metrology and secure communications. In the high-gain regime of PDC, the physics is most often discussed in terms of bright squeezed vacuum (BSV) [ 2 ] , which corresponds to the degenerate case of PDC— where signal and idler are indistinguishable in the detection setup—and bright twin beams (BTB) [ 3 ] in the non-degenerate case—where the observables associated with signal and idler can be detected separately. Non-classical correlations persist even at those macroscopic photon numbers, enabling sub-shot-noise measurements when single-photon counting might be impractical [ 4 , 3 ] . Prior work has clarified how increasing the gain reshapes the spectral and correlation properties of PDC emission, including gain-dependent changes of bandwidth and pairwise spectral correlations [ 5 , 6 , 7 , 8 ] . Near-single-mode operation ensures that the generated state is a single entangled set of twin beams rather than a tensor product of independent entangled sets across orthogonal Schmidt modes [ 9 , 10 ] (theory extended to bright twin beams in Supplemental Secs. S3 , S4 , S5 ). As developed in Sec. 3 , near-single-mode operation makes the entanglement resource fully accessible without mode-sorting by direct broadband detection in continuous-variable [ 11 ] and nonlinear-interferometric schemes [ 12 , 13 , 14 ] , and in photon-number conditioning protocols such as electro-optic sampling (EOS) [ 15 ] (see Supplemental Secs. S3 , S4 ). In contrast, controlled multimode operation supports multiplexed quantum-information distribution across classical degrees of freedom such as frequency, time, or transverse profile. Figure 1: \justifying Generation of ultrafast bright entangled twin-beams. a) Experimental setup. A pump beam ( 1026\text{\,}\mathrm{nm} , 260\text{\,}\mathrm{fs} , 5\text{\,}\mathrm{\SIUnitSymbolMicro J} ) is attenuated with a neutral density filter (ND1) and focused into a periodically-poled Lithium Niobate (PPLN) crystal of 2-mm length with a 27.91\text{\,}\mathrm{\SIUnitSymbolMicro m} poling period, using a lens (L1) with 250\text{\,}\mathrm{mm} focal length. A mirror (M1) reflects the beam back into the crystal for additional nonlinear interaction. The PPLN is positioned so that the pump’s focal plane is at the second pass. The beam is collimated by a concave mirror (CM1) with a focal length of 150\text{\,}\mathrm{mm} . The signal twin ( 1.37\text{\,}\mathrm{\SIUnitSymbolMicro m} , 100\text{\,}\mathrm{fs} ), idler twin ( 4.0\text{\,}\mathrm{\SIUnitSymbolMicro m} , 100\text{\,}\mathrm{fs} ) and pump are separated using a pair of dichroic mirrors (DM1 and DM2). The signal twin is then sent towards measurement devices, while the idler is not studied in this work. b) Average number of signal photons generated per pulse as a function of the average number of pump photons. The dashed line is a fit of the expected number of generated signal photons, showing signs of saturation for \expectationvalue{N_{\rm P}}>$1.4\text{\times}{10}^{13}$ . Bright squeezed vacuum has also recently emerged as a driver of strong-field and nonlinear processes, with the non-classical photon statistics of the driving field imprinted onto the strong-field response across platforms ranging from perturbative harmonic generation [ 16 ] and non-perturbative high-harmonic generation in solids [ 17 ] to quantum-controlled high-harmonic sideband emission [ 18 ] and multiphoton electron emission from nanostructures [ 19 , 20 ] . This is supported by theoretical predictions of modified cutoff laws, photon-statistics forces, and squeezed harmonics [ 21 , 22 , 23 , 24 ] . Reciprocally, the high-harmonic process itself generates radiation carrying non-classical statistics including squeezing and entanglement [ 25 , 26 ] , and BSV quantum correlations have been transferred onto XUV attosecond pulses, enabling attosecond-resolved measurements of quantum fluctuations in both light and matter [ 27 ] . For both directions, single-mode operation maximizes the peak quantum field amplitude available to the strong-field interaction while preserving the non-classical statistics on which these processes depend. There also exists a strong motivation for sources of strongly non-degenerate twin beams because they decouple the wavelength best suited for interaction from the wavelength best suited for detection . This separation is particularly compelling when one twin reaches mid-infrared (mid-IR) wavelengths that overlap with molecular vibrational resonances. The absorbance of the mid-IR twin is imprinted onto the near-IR twin, which is generated to overlap with high-quantum-efficiency, low-noise detectors. This idea also underlies nondegenerate nonlinear interferometry, notably SU(1,1) interferometers [ 12 , 13 , 28 ] , and “undetected-photon” sensing and imaging [ 14 , 29 , 30 ] . Here we demonstrate an ultrafast, bright, entangled, strongly non-degenerate twin-beam source in the near- and mid-infrared, generated by type-0 parametric down-conversion (PDC) in periodically-poled lithium niobate (PPLN) crystal. The signal is centered near 1.37\text{\,}\mathrm{\SIUnitSymbolMicro m} and the idler near 4.0\text{\,}\mathrm{\SIUnitSymbolMicro m} , with pulse durations on the order of 100\text{\,}\mathrm{fs} . We verify near-single spatio-temporal mode operation over multiple orders of magnitude in brightness using two independent diagnostics of the signal beam: photon-number statistics via the second-order correlation function at zero delay g^{(2)}(0) and singular-value (or Schmidt) decomposition of the measured spectral intensity covariance. Finally, we identify the pump pulse duration as a key control parameter: increasing it via added group-delay dispersion (GDD) drives a transition from single-mode to multimode amplification , consistent with the intuitive requirement that the temporal gain window be matched to the inverse phase-matching bandwidth, most directly understood through the picture of space-time volumetric amplification of the input vacuum state [ 31 , 32 ] . 2 Modes of Bright Twin-Beams Bright twin-beam states are generally multimode (in the sense of first quantization) in both space/wavevector and time/frequency, and the effective number of occupied modes can evolve with gain, pump parameters, and collection geometry [ 7