Status of Barrel Imaging Calorimeter in Korea for the Electron-Ion Collider
\firstname Jeongsu \lastname Bok \fnsep · 2026
Read Status of Barrel Imaging Calorimeter in Korea for the Electron-Ion Collider by \firstname Jeongsu \lastname Bok \fnsep (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-15288.txt.
Introduction
Jeongsu Bok reports the Korean contribution to the Barrel Imaging Calorimeter for the Electron-Ion Collider, a site probing nucleon mass, spin, and quark-gluon motion. As the barrel electromagnetic calorimeter, the tool must measure electron and photon energies exactly and tell them apart from background pions. It joins lead-glowing-fiber sampling layers with AstroPix silicon pixel sensors for 3D shower imaging. Korean work spans chip testing, module build, models, beam tests, readout design, and simulation.
Catalog record
| CREATOR | \firstname Jeongsu \lastname Bok \fnsep |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 8576 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.15288
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Status of Barrel Imaging Calorimeter in Korea for the Electron-Ion Collider \firstname Jeongsu \lastname Bok \fnsep Abstract The Electron-Ion Collider (EIC) is a next-generation particle accelerator facility designed to probe the fundamental structure of matter such as the origins of nucleon mass, spin, and the dynamic behavior of quarks and gluons within nucleon and nucleus. As the electromagnetic calorimeter in the barrel region, the Barrel Imaging Calorimeter (BIC) is tasked with precise energy measurements of electrons and photons as well as efficient separation of these particles from background pions. The BIC integrates Pb/SciFi sampling layers and AstroPix silicon pixel sensors for three-dimensional shower imaging. The Korean group has actively contributed through silicon chip testing, module assembly, prototype development, beam test, readout system design, and detailed simulations. This presentation highlights the recent progress and plans for the R&D of the Barrel Imaging Calorimeter in Korea. 1 Introduction The Electron-Ion Collider (EIC) AbdulKhalek:2021gbh will explore how quarks and gluons build the mass, spin, and structure of visible matter. It will operate with polarized electron and hadron beams (5–18 GeV electrons and 41–275 GeV protons or ions), reaching luminosities up to 10^{33} – 10^{34} cm -2 s -1 . Precision 3D imaging of nucleons and nuclei requires high-performance calorimetry in the barrel region of the general-purpose EIC detector. The ePIC (The Electron-Proton/Ion Collider) experiment is the first experiment at EIC. The Barrel Imaging Calorimeter (BIC) is designed as the electromagnetic calorimeter in the barrel region -1.7<\eta<1.4 , where \eta=-\ln[\tan(\theta/2)] and \theta is the polar angle with respect to the beam axis. The energy resolution of 10\%/\sqrt{E}\oplus(2-3)\% and electron–pion separation of 10^{4} at low momenta are required AbdulKhalek:2021gbh . Additionally, it should provide good photon reconstruction down to \sim 100 MeV and \pi^{0} discrimination up to \sim 10 GeV. These requirements motivate an imaging-type electromagnetic calorimeter combining Lead-Scintillating Fiber (Pb/SciFi) layers and silicon pixel layers. 2 Design Concept of the BIC The BIC combines two subsystems: (i) Pb/SciFi sampling layers for energy measurement and (ii) AstroPix silicon pixel layers for shower imaging as shown in Figure 1 . The Pb/SciFi sampling calorimeter is based on the BCAL at GlueX experiment and the AstroPix silicon pixel detector was developed for the NASA Amego-X mission GlueX:2020idb ; Steinhebel:2025pra . The baseline design features 4 imaging layers of silicon pixel layers interleaved with 5 Pb/SciFi layers, followed by a bulk section of Pb/SciFi. The total radiation length is about 17 X_{0} , where X_{0} is the characteristic length over which a high-energy electron loses all but 1/e of its energy by bremsstrahlung. The sampling fraction of the calorimeter is approximately 10%. AstroPix layers provide fine position resolution and 3D shower profiling, while the sampling calorimeter determines energy. The full barrel calorimeter will cover about 100 m 2 using \sim 2.5 \times 10 5 AstroPix chips ( \sim 2 \times 2 cm 2 each). Figure 1 : Design of the Barrel Imaging Calorimeter. 3 Korean Contributions and Prototype Development In the BIC project, the Korean group is contributing to several core tasks: (i) AstroPix chip testing and wafer-level evaluation, (ii) Pb/SciFi production, (iii) Readout box development, (iv) GEANT4 simulation and system-level performance studies. The Korean group is preparing the mass chip test. For the mass chip test, multi-line single-chip test system is in consideration because one chip handler can cover multiple test stations depending on the test procedure and time. During the recent beam test at KEK in March 2025, connection with a flexible cable has been tested as shown in Fig. 2 . The flexible cable would be also useful for the future beam test in order to locate AstroPix modules between Pb/SciFi layers. Figure 2 : AstroPix v3 single chip setup for lab test (Left) and flexible cable test at KEK PF-AR test beam line in March 2025 (Right). 3.1 Pb/SciFi Prototype Modules Prior to the beam tests, Korean group prepared a set of prototype modules. The dimension of a unit module is \rm 32\times 3\times 3\ cm^{3} . To produce a unit module, Pb plates with 0.5 mm thickness are shaped with press, then stacked with scintillating fibers (1 mm diameter), cured, and polished as shown in Fig. 3 . A total of 33 modules were produced in Korea, including one with a light-guide prototype. The modules were instrumented with PMTs or SiPMs in the beam tests. Bundling and connection between the fibers and the PMT (or SiPM) were made using 3d-printed cases. Figure 3 : Production procedure of a unit module includes stacking of lead plates and scintillating fibers, curing, and polishing. 4 Beam Test Results 4.1 CERN PS T10 (August 2024) The first beam test was conducted using 0.5–3 GeV/ c electron beams at CERN PS T10 in 2024. The beam was a mixture of charged pions, electrons, and other particles. The identification of electron was performed using the Cherenkov counters at the beam line. As shown in Fig. 4 , a trigger composed of two 1-cm-thick scintillators and PMTs was installed. Two Delay Wire Chambers were used to reject scattered beam particles. The calorimeter was composed of 3 \times 5 array of unit modules, giving a total detector size of \rm 32(h)\times 9(w)\times 15(d)\ cm^{3} as shown in Fig. 5 . The depth corresponds to \sim 11 \rm X_{0} . The signal from PMTs was collected by Flash ADC. During the experiment, we conducted electron calibration successfully and collected data for 0.5–3 GeV/ c electrons. Data are being analyzed for obtaining energy resolution as shown in Fig. 6 . Figure 4 : Experimental setup in the beam test at CERN PS T10. Figure 5 : The total dimension of the Pb/SciFi was \rm 32(h)\times 9(w)\times 15(d)\ cm^{3} . A 3 \times 5 array of unit modules was formed. A Pb/SciFi unit module equipped with SiPM was installed on top of it. Figure 6 : Response of the Pb/SciFi from 0.5, 1, 2, and 3 GeV/ c electron beam in the beam test at CERN PS T10. 4.2 KEK PF-AR (March 2025) The second beam test used a 4 \times 7 array of Pb/SciFi modules ( \sim 15 X 0 depth) and included AstroPix layers placed between Pb/SciFi modules as shown in Figs. 7 and 8 . Electron beams of 0.5–5 GeV were used to study the energy and position response in Fig. 9 , longitudinal and transverse profiles. Figure 7 : Beam test setup at KEK PF-AR testbeam line. Two trigger counters and a hodoscope with scintillating fibers were installed in front of Pb/SciFi calorimeter. Figure 8 : During the beam test at KEK PF-AR, AstroPix v3 was located between Pb/SciFi layers using an extension cable. In front of the Pb/SciFi layer, a single-chip setup with GECCO board was installed. In the beam test at KEK PF-AR, AstroPix signals recorded through the GECCO + FPGA development board were recorded simultaneously with signals from other detectors including Pb/SciFi using the new DAQ system produced in Korea. Preliminary correlations between beam positions on AstroPix and wire-chamber drift times were checked. This demonstrates the feasibility of synchronized data taking of silicon layers and Pb/SciFi layers, a key milestone for 3D shower imaging. This will be very useful for performance test under beam environment. Figure 9