PG-LRF: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation
Xiaoda Wang, Minxiao Wang, Kaiqiao Han, Defu Cao, Ching Chang, Yidan Shi, Runze Yan, Xiao Luo, Yan Liu, Xiao Hu, Yizhou Sun, Wei Wang, Carl Yang, [2mm] Department of Computer Science, Emory University · 2026
Read PG-LRF: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation by Xiaoda Wang, Minxiao Wang, Kaiqiao Han, Defu Cao, Ching Chang, Yidan Shi, Runze Yan, Xiao Luo, Yan Liu, Xiao Hu, Yizhou Sun, Wei Wang, Carl Yang, [2mm] Department of Computer Science, Emory University (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-12541.txt.
Introduction
Wang and twelve colleagues generate ECG traces from wearable pulse signals, bridging a hardware gap. ECG is the clinical standard for heart assessment but needs dedicated gear, while PPG from wearables lacks ECG diagnostic shape and suffers motion and sensor noise. Their PG-LRF framework uses an electro-hemodynamic simulator co-modelling ECG and PPG via shared cardiac phase dynamics. A physiology-aware autoencoder then learns a structured latent space around those dynamics, so pulse signals can yield electrical morphology and timing without ECG hardware.
Catalog record
| CREATOR | Xiaoda Wang, Minxiao Wang, Kaiqiao Han, Defu Cao, Ching Chang, Yidan Shi, Runze Yan, Xiao Luo, Yan Liu, Xiao Hu, Yizhou Sun, Wei Wang, Carl Yang, [2mm] Department of Computer Science, Emory University |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 59780 |
| LICENSE | http://creativecommons.org/licenses/by-sa/4.0/ |
| RIGHTS | CC BY SA |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.12541
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
PG-LRF: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation Xiaoda Wang, Minxiao Wang, Kaiqiao Han, Defu Cao, Ching Chang, Yidan Shi, Runze Yan, Xiao Luo, Yan Liu, Xiao Hu, Yizhou Sun, Wei Wang, Carl Yang, [2mm] Department of Computer Science, Emory University Abstract Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PG-LRF , a physiology-guided latent rectified flow framework. PG-LRF introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PG-LRF significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway. 1 Introduction Electrocardiography (ECG) is the clinical standard for measuring cardiac electrical activity and diagnosing cardiovascular conditions ( 14 ; 32 ; 2 ) . However, continuous ECG monitoring requires dedicated electrodes and stable skin contact, limiting its scalability in daily-life settings. Photoplethysmography (PPG), in contrast, is widely available in consumer wearables, offering a low-cost measurement of peripheral blood-volume changes ( 1 ; 4 ) . Despite its appeal, PPG is fundamentally limited by high levels of motion artifacts and the inherent absence of diagnostic electrical features like P-QRS-T morphology ( 11 ; 3 ) . As a delayed hemodynamic response, raw PPG is structurally deficient for direct and reliable clinical diagnosis. Overcoming this bottleneck by generating diagnostically informative ECGs from wearable PPG therefore provides a highly meaningful bridge between ubiquitous sensing and verifiable cardiac assessment ( 27 ; 31 ; 28 ) . Recent PPG-to-ECG studies have progressed from supervised waveform reconstruction to adversarial and latent diffusion-based generation ( 31 ; 28 ; 7 ; 10 ) . Despite these advances, most existing methods treat PPG-to-ECG generation primarily as a data-driven cross-modal translation problem, leaving two key challenges: (i) Lack of physiology-aware latent abstraction. PPG and ECG are coupled but asymmetric observations of the same cardiovascular process: ECG reflects upstream electrical activation, whereas PPG captures the delayed peripheral pulse. Purely statistical alignment fails to explicitly encode this directional physiological coupling. (ii) Missing physiological simulator guidance. Existing methods optimize data-driven signal similarity and easily hallucinate physically impossible hemodynamic delays, ignoring cardiac-cycle dynamics and the forward ECG-to-PPG hemodynamic pathway ( 31 ; 24 ) . Incorporating this knowledge is non-trivial; naively imposing a fixed simulator as a hard constraint risks severe model mismatch and over-regularization. A robust approach must instead integrate simulator knowledge as soft, phase-aware guidance while retaining the flexibility of data-driven latent generation. To address these challenges, we propose PG-LRF, a physiology-guided latent rectified flow framework for electro-hemodynamic PPG-to-ECG generation. We introduce a novel electro-hemodynamic simulator that explicitly co-models ECG and PPG by linking an upstream electrical readout with a delayed peripheral pulse via shared cardiac phase dynamics. Using this simulator as a physiological anchor, PG-LRF employs a Physiology-Aware AutoEncoder (PAE) to abstract modality-specific observations into a structured cardiovascular latent space regularized by cross-modal alignment and latency-aware consistency. On top of this latent space, PG-LRF introduces a simulator-guided latent rectified flow. During training, the generative transport is explicitly regularized by the simulator to ensure both ECG-side morphological fidelity and forward ECG-to-PPG hemodynamic consistency. In summary, our main contributions are as follows: ❶ Physiology-Guided Generative Formulation. We introduce PG-LRF, formulating PPG-to-ECG generation as an electro-hemodynamic generation problem. We design an electro-hemodynamic physiological simulator to co-model ECG and PPG through shared cardiac phase dynamics, upstream electrical readouts, and delayed hemodynamic readouts. ❷ Physiology-Aware Representation Learning. We design a Physiology-Aware AutoEncoder that abstracts modality-specific observations into a structured electro-hemodynamic latent space, rigorously constrained by simulator-derived latency-aware consistency, and cross-modal latent alignment. ❸ Simulator-Guided Flow Matching. We integrate the electro-hemodynamic simulator into PPG-conditioned latent rectified flow. Simulator-derived constraints guide the model to generate ECGs that are waveform-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway. ❹ Multi-Level Experimental Validation. We demonstrate that PG-LRF consistently improves PPG-to-ECG generation across waveform fidelity, clinical interval consistency, and cardiovascular disease detection on the large-scale MC-MED dataset. 2 Related Work PPG-to-ECG Generation. PPG-to-ECG generation aims to recover cardiac electrical waveforms from PPG. Early methods treated this as supervised signal reconstruction, utilizing CNNs, RNNs, or Transformers ( 15 ) and specialized architectures like W-Net ( 31 ) . To enhance waveform realism, subsequent works adopted generative models. For example, CardioGAN ( 27 ) and CLEP-GAN ( 17 ) employed adversarial and contrastive learning to improve subject-independent translation. More recently, diffusion and flow-based models have driven state-of-the-art high-fidelity translation. RDDM ( 28 ) utilizes a region-disentangled diffusion process for targeted ECG components, while CardioPPG ( 7 ) generates ECGs through a tokenized frequency-domain pathway. Most closely related to our work, PPGFlowECG ( 10 ) employs a two-stage latent rectified flow, generating ECGs from a shared cross-modal latent space. Despite these advancements, existing models rely predominantly on statistical data-driven alignment, lacking explicit regularization from forward physiological dynamics. Physiological Simulators. Compact mathematical models utilize low-dimensional differential equations to simulate the cardiac cycle and generate stereotyped cardiovascular waveforms ( 20 ; 8 ) . The canonical ECGSYN model ( 20 ) , for instance, employs a three-dimensional limit-cycle oscillator with phase-locked Gaussian components to synthesize realistic P–QRS–T morphologies and heart rate variability. Similar oscillator-based frameworks have since been developed to model delayed peripheral hemodynamics, such as PPG ( 30 ) . However, purely mechanistic simulators rely on globally fixed templates, limiting their expressivity in capturing subject-specific conduction abnormalities or complex cross-modal variations. To overcome this, recent hybrid approaches integrate physiological priors with Neural ODEs ( 5 ) or Universal Differential Equations ( 24 ) . They can enable models to preserve essential electro-hemodynamic structures while flexibly fitting real-world clinical data ( 26 ) . 3 Method: PG-LRF We present PG-LRF, a physiology-guided latent rectified flow framework for electro-hemodynamic PPG-to-ECG generation. PG-LRF has three components. First, an electro-hemodynamic physiological simulator co-models ECG and PPG through shared cardiac phase dynamics, an upstream ECG readout, and a delayed PPG readout. Second, a Physiology-Aware AutoEncoder (PAE) learns a modality-aware shared latent space regularized by cross-modal alignment and simulator-derived latency consistency. Third, a PPG-conditioned latent rectified flow generates ECG latents from Gaussian noise, while simulator-derived residuals guide the transport toward ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency. The simulator and the ECG-to-PPG forward mapper are used only during training; inference requires only the input PPG. Problem Formulation. Given a paired PPG segment \mathbf{x}_{p}\in\mathbb{R}^{L_{p}\times 1} and ECG segment \mathbf{x}_{e}\in\mathbb{R}^{L_{e}\times 1} , where L_{p} and L_{e} denote their native temporal lengths, our goal is to learn a conditional