Design of a validation methodology for a prototype wristband for capturing muscle signals and upper limb movement
Miguel Alejandro Mantilla, Ana Maria Montañez, Daniel Escobar Saltarén, Sofía C. Henao, María B. Salazar-Sánchez · 2026
Read Design of a validation methodology for a prototype wristband for capturing muscle signals and upper limb movement by Miguel Alejandro Mantilla, Ana Maria Montañez, Daniel Escobar Saltarén, Sofía C. Henao, María B. Salazar-Sánchez (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2605-11148.txt.
Introduction
Miguel Alejandro Mantilla and four colleagues design a testing method for a prototype wristband reading muscle signals and upper-limb movement. Surface electromyography drives myoelectric prosthetic limbs and human-machine interfaces, but store-bought systems cost too much for many school, lab, and factory settings, especially in poorer countries.
Their plan follows global standards IEC 60601 and ANSI/AAMI EC13, running safety tests for power for leakage currents, double insulation, and electrode-circuit links. Use tests compare an eight-electrode wristband sample against the store-bought PortiLab2 reference using Pearson correlation, Bland-Altman analysis, and mean squared error, extended to signal steadiness at rest and during movement. Low-cost prosthetics teams get a standards-based testing route for affordable recording gear.
Catalog record
| CREATOR | Miguel Alejandro Mantilla, Ana Maria Montañez, Daniel Escobar Saltarén, Sofía C. Henao, María B. Salazar-Sánchez |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 48298 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2605.11148
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Design of a validation methodology for a prototype wristband for capturing muscle signals and upper limb movement Miguel Alejandro Mantilla, Ana Maria Montañez, Daniel Escobar Saltarén, Sofía C. Henao, María B. Salazar-Sánchez Abstract Surface electromyography (sEMG) is a non-invasive technique that is widely used to control myoelectric prostheses and other human–machine interfaces. However, the high cost of commercial systems can limit accessibility in academic, research, and industrial settings, particularly in developing countries. To address this issue, the development of low-cost acquisition systems has been promoted, which requires assurance of electrical safety and the reliability of the acquired signals. Against this backdrop, this article presents a validation protocol based on international standards, including IEC 60601 and ANSI/AAMI EC13. Based on these standards, electrical safety tests are implemented, including measuring leakage currents under normal conditions, evaluating double insulation, and verifying continuity between electrodes and circuits. Additionally, the article incorporates functional evaluations of the system by comparing signals acquired from an eight-electrode sEMG wristband prototype with those from a commercial reference device (PortiLab2). This comparison uses statistical metrics such as Pearson’s correlation, Bland–Altman analysis, and mean squared error. These evaluations are expanded to include tests of signal stability under resting and contraction conditions, validation of UART and Bluetooth communication, frequency response analysis, mechanical characterization of the casing, and evaluation of user comfort. The results show leakage currents ranging from 11.4 µA to 13.5 µA, slightly above the established threshold, and a bias current close to the regulatory limit. Adequate insulation, clear differentiation between muscle signals and noise, and high correlation with the reference system (r > 0.85) were demonstrated, along with stable, loss-free data transmission. One limitation is that constraints were identified at the power-supply stage, necessitating the use of an external power source during wireless testing. In addition, discrepancies were observed in the frequency response relative to the simulation, particularly at high-gain stages. The casing exhibited elastic behavior under loads up to 98 N. These results enable us to establish a minimum technical and functional validation framework for low-cost sEMG systems intended for research and training. Furthermore, the proposed protocol can be implemented using basic laboratory equipment by a single operator, providing a practical, reproducible, and accessible methodology for validating biomedical devices in research settings. K eywords Surface Electromyography \cdot Electrical Safety Validation \cdot Low-Cost Biomedical Devices \cdot Signal Reliability Analysis \cdot Human–Machine Interfaces 1 Introduction Surface electromyography is a non-invasive technique used to record the electrical activity generated by muscles during contraction, thereby enabling the identification of users’ movement intentions for controlling myoelectric prostheses and other human–machine interfaces [ 9 ] [ 8 ] . This signal is widely applied in areas such as rehabilitation, neuromuscular diagnosis, and biomechanical analysis, due to its ability to capture neural information in real time without requiring invasive procedures [ 10 ] . Consequently, the acquisition of sEMG signals, often combined with motion data, has gained increasing relevance in the development of portable and wearable systems. However, access to commercial equipment for the reliable acquisition of sEMG signals remains limited, particularly in academic environments or settings with limited budgets. Devices such as Delsys Trigno and Cometa® systems can exceed USD 10,000 per unit [ 2 ] , restricting their implementation to well-resourced institutions. Additionally, costs associated with accessing international standards required for device validation, such as IEC 60601 and ANSI/AAMI EC13 [ 1 ] , further limit their adoption. As a result, numerous low-cost sEMG acquisition prototypes, particularly wearable armbands, have been developed in academic and research settings. These prototypes are generally not intended for clinical use and lack formal certification. Nevertheless, given their direct contact with human skin, ensuring electrical safety and the reliability of acquired signals is essential. This lack of standardization often results in uncertainty about their technical performance and safe operation. Furthermore, previous studies have shown that a significant proportion of adverse events related to medical devices are associated with technical failures rather than clinical use, highlighting the need for systematic and objective evaluation frameworks [ 3 ] . In addition, in countries such as Colombia, the limited availability of certified laboratories capable of conducting this type of validation represents an additional barrier to the development and safe implementation of emerging biomedical technologies [ 1 ] . In this context, the development of structured and accessible validation protocols is crucial not only to support regulatory alignment but also to ensure reliable device performance under real-world conditions. This article presents the technical characterization and validation of a custom-designed modular 8-channel sEMG armband equipped with dry electrodes and an Inertial Measurement Unit (IMU). The core contribution of this work is the design and implementation of a replicable validation protocol based on international standards such as IEC 60601-1, which establishes safety requirements for medical electrical equipment. The proposed protocol evaluates electrical safety through leakage current measurements, signal quality compared to a commercial reference device (PortiLab2), structural integrity through mechanical testing, and data transmission stability. In addition, it incorporates assessments of signal stability, synchronization, data integrity, ergonomics, and usability. The objective is to establish a clear methodological framework for evaluating similar low-cost sEMG systems and to facilitate their implementation in applied research and training contexts in bioengineering [ 6 ] . 2 Materials and Methods 2.1 Device Description The sEMG armband features a modular structure to facilitate manufacturing, evaluation, and adaptability to different usage contexts. It incorporates eight sEMG electrodes integrated into an elastic silicone band, allowing adjustment for different forearm sizes. Each sensing unit consists of metallic electrodes arranged in a differential configuration and housed within 3D-printing enclosures to protect the internal circuitry and ensure stable mechanical attachment. Additionally, the device uses an ESP32-S3 [ 5 ] microcontroller to handle data acquisition, processing, and transmission. The analog-to-digital conversion of the sEMG signals is performed using an ADS1015 [ 12 ] converter, which provides a 14-bit resolution and a sampling rate of up to 800Hz per channel. Furthermore, the system incorporates an IMU [ 11 ] that provides complementary information about acceleration and forearm orientation. This information is useful in applications where a correlation between movement and muscular activity is required. The EMG signal is conditioned through a pre-filtering stage, followed by amplification with an AD620 instrumentation amplifier [ 4 ] . Subsequently, band-pass filtering is applied, consisting of second-order active Butterworth high-pass and low-pass filters, along with a second-order twin-T notch filter to attenuate power-line interference. Additionally, an analog processing stage is implemented to generate a rectified envelope signal, which is useful for representing muscle contraction intensity in real time. The system supports data transmission through two interfaces: a Universal Asynchronous Receiver–Transmitter (UART) for wired communication and Bluetooth Low Energy (BLE) for wireless transmission. A graphical user interface developed in Python enables real-time signal visualization, data storage in .xlsx format, and basic system configuration, facilitating its use in validation environments and pilot testing. 2.2 Normative Reference Armband validation was conducted in accordance with international standards that establish safety and performance requirements for medical electrical devices. In particular, IEC 60601-1 was used as a reference standard because it defines essential safety requirements for electromedical equipment, including protection against electrical hazards, limits on leakage currents, insulation requirements, classification of applied parts, and operation under normal conditions.